R9 Valve - 9 mm Miniature Diaphragm Isolation Valve

Picture for category R9 Valve - 9 mm Miniature Diaphragm Isolation Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker R9 valve delivers the liquid flow capabilities of a 16 mm valve in a 9 mm envelope. The R9 valve includes a 44% reduction in width with unrivaled flows and pressures up to 100 psi. Designed to offer low carryover performance with particulate and crystallization resistance, this valve is ideally suited for today’s demanding liquid handling applications. The R9 supports the performance requirements of current and future laboratory and portable instrumentation.

Markets:
• Clinical Diagnostics
• Analytical Chemistry
• Agent Detection
• Environmental Monitoring

Features/Benefits
• High pressure options available up to 100 PSI (6.9 bar)
• Easy mounting on 9 mm centers side to side, accommodating dispense over 96 well microplates
• Low unswept volume to minimize carryover
• Particulate and crystallization resistant
• 100% tested leak rate ensures a leak tight seal on every valve
• CE, REACH, and RoHS compliant

Applications:
• Sampling, Wash & Waste
• Reagent Addition
• Flow Control
• Clinical Diagnostics Instrumentation
• Hematology
• Automated Slide Stainers
• DNA/RNA Synthesis

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceConfigurationInput VoltageMaximum Operating PressureMaximum Operating TemperatureActuation TypeDivisionOperation TypeMinimum Operating TemperatureFor Fluid TypeStandard Lead TimeOut of Stock Lead TimeLeak RateBody MaterialMounting TypeCycles per LifetimeSeal MaterialMax Order QuantityValve TypeConnection TypeElectrical ConnectionWeightHeightShipping WeightWidthLengthFlow RateOrifice SizeResponse TimeControl MethodConnection SizeMaximum Flow RatePower ConsumptionIndustry ApplicationFunctionValve TypeElastomerOrifice SizeMounting StyleElectrical ConnectionMaximum Operating VoltageApplication Pressure Requirement
R9-324FF6H4F-000
Quote Required
TBD
n/a24 VDC2.8 bar122 °FSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz37 mm0.35 oz8.7 mm68.8 mmUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)1/4-2818 in(46 cm) Flying Leads24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6H4P-000
Quote Required
TBD
n/a24 VDC40 psi50 °CSolenoidPrecision Fluidics DivisionElectronic32 °FLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins38.4 g1.46 inch0.35 oz0.34 inch68.8 mmUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)1/4-282.54 mm Male Pins24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6HFF-000
Quote Required
TBD
n/a24 VDC2.8 bar50 °CSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveManifold Face SealWire Leads1.35 oz1.46 inch0.35 oz0.34 inch68.8 mmUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitManifold face seal700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)Face Seal Manifold Mount18 in(46 cm) Flying Leads24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6HFP-000
Quote Required
TBD
n/a24 VDC2.8 bar122 °FSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveManifold Face Seal2.54 mm pins1.35 oz37 mm0.35 oz0.34 inch2.71 inchUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitManifold face seal700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)Face Seal Manifold Mount2.54 mm Male Pins24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6HMF-000
Quote Required
TBD
n/a24 VDC40 psi50 °CSolenoidPrecision Fluidics DivisionElectronic32 °FLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads38.4 g1.46 inch0.35 oz8.7 mm68.8 mmUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitM6 threaded port connections700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)M618 in(46 cm) Flying Leads24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6HMP-000
Quote Required
TBD
n/a24 VDC2.8 bar50 °CSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz1.46 inch0.35 oz0.34 inch2.71 inchUp to 700 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitM6 threaded port connections700 ml/min1.8 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)M62.54 mm Male Pins24 VoltVAC to 40 psi (2.8 bar)
R9-324FF6L4F-000
Quote Required
TBD
n/a24 VDC1.4 bar50 °CSolenoidPrecision Fluidics DivisionElectronic32 °FLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads1.35 oz1.46 inch0.35 oz8.7 mm68.8 mmUp to 580 ml/min0.061 inch< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)1/4-2818 in(46 cm) Flying Leads24 VoltVAC to 20 psi (1.36 bar)
R9-324FF6L4P-000
Quote Required
TBD
n/a24 VDC1.4 bar122 °FSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz37 mm0.35 oz0.34 inch68.8 mmUp to 580 ml/min0.061 inch< 18 ms max cyclingHit and hold circuit1/4-28 UNF threaded port connections580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)1/4-282.54 mm Male Pins24 VoltVAC to 20 psi (1.36 bar)
R9-324FF6LFF-000
Quote Required
TBD
n/a24 VDC1.4 bar50 °CSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveManifold Face SealWire Leads38.4 g37 mm0.35 oz8.7 mm2.71 inchUp to 580 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitManifold face seal580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)Face Seal Manifold Mount18 in(46 cm) Flying Leads24 VoltVAC to 20 psi (1.36 bar)
R9-324FF6LFP-000
Quote Required
TBD
n/a24 VDC1.4 bar50 °CSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveManifold Face Seal2.54 mm pins1.35 oz37 mm0.35 oz8.7 mm68.8 mmUp to 580 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitManifold face seal580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)Face Seal Manifold Mount2.54 mm Male Pins24 VoltVAC to 20 psi (1.36 bar)
R9-324FF6LMF-000
Quote Required
TBD
n/a24 VDC20 psi50 °CSolenoidPrecision Fluidics DivisionElectronic32 °FLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port ConnectionsWire Leads38.4 g37 mm0.35 oz0.34 inch68.8 mmUp to 580 ml/min0.061 inch< 18 ms max cyclingHit and hold circuitM6 threaded port connections580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)M618 in(46 cm) Flying Leads24 VoltVAC to 20 psi (1.36 bar)
R9-324FF6LMP-000
Quote Required
TBD
n/a24 VDC20 psi122 °FSolenoidPrecision Fluidics DivisionElectronic0 °CLiquids2040Bubble TightPEEKMounting Screw10 MillionFFKM10Diaphragm Rocker Isolation ValveThreaded Port Connections2.54 mm pins1.35 oz37 mm0.35 oz8.7 mm2.71 inchUp to 580 ml/min1.55 mm< 18 ms max cyclingHit and hold circuitM6 threaded port connections580 ml/min1.2 WClinical Diagnostics, Analytical Chemistry, Agent Detection, Environmental Monitoring, Sampling, Reagent Addition, Flow Control,Wash, Waste3-Way, Universal3-Way UniversalFFKM0.061 in (1.55 mm)M62.54 mm Male Pins24 VoltVAC to 20 psi (1.36 bar)