QPL PTFE AWG & Fractional 2:1 Heat Shrinkable Tubing
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's QPL-approved AS23053/12 PTFE Heat Shrink Tubing protects components from heat, sparks, and contaminants while handling long-term exposure to temperatures as high as 500°F (260°C). When heated, it conforms to the object's shape, providing a protective covering. PTFE AWG 2:1 and Fractional 2:1 heat shrink is produced in Heavy Wall, Standard Wall, Thin Wall, and Light Wall designs and supplied in an expanded state, allowing easy slippage over cables, fittings, and other protrusions.
PTFE AWG heat shrinkable tubing is typically used when repairing electrical wiring, fittings, cords and other small objects that need to be protected from heat, water, dust or corrosion. Fractional 2:1 heat shrink is used to protect larger objects like electrical harnesses, instruments, or even lighting where a breakage would compromise the operation.
QPL 23053/12 PTFE heat shrink is ideal for repairing electrical wiring, catheter manufacturing, and protecting harnesses, instruments, and lighting from heat, water, dust, or corrosion. Its thin wall promotes quick installation and flexibility. The thin wall also keeps the tubing flexible when flexibility is an issue.
Parflex also offers turnkey services for heat shrink. Even on very difficult applications, like balloon catheters, Parker can cut and score the tubing for easy peel back, ensuring quicker installation and consistency. In addition, outsourcing reduces scrap and allows you to use the product immediately upon receipt without using additional space in your warehouse for carrying inventory.
Markets:
• Industrial
• Medical
• Government
• Electrical
Features/Benefits:
• 2:1 shrink ratio for easy slippage over component
• QPL-approved AS23053/12
• Exceptional heat resistance
• Chemical resistant
• Chemically inert
• When used in electrical insulation, exhibits superior dielectric strength
• Lowest coefficient of friction aids in sliding
• Self-extinguishing
• Non-wetting
Applications:
• Protective covering for components
• Electrical insulation
• Applications where fire hazards are present
• Bulb protection
• Harnesses
• Laboratory
Certifications/Compliance:
• QPL-approved AS23053/12
• ASTM D2902 Type I
• USP Class VI compliant• 21 CFR 177.1550 compliant • UL 94 V-0 compliant
Specifications:
• Recovered wall thickness is nominal
• Shrink Temperature: 662°F/350°C for 10 minutes per AMS-DTL-23053/12A
• Dielectric Strength: > 1,400 V/M, per ASTM D 149 short term test of 10 MIL thickness (Volts/MIL)
•Colors available as custom run
Read More...PTFE AWG heat shrinkable tubing is typically used when repairing electrical wiring, fittings, cords and other small objects that need to be protected from heat, water, dust or corrosion. Fractional 2:1 heat shrink is used to protect larger objects like electrical harnesses, instruments, or even lighting where a breakage would compromise the operation.
QPL 23053/12 PTFE heat shrink is ideal for repairing electrical wiring, catheter manufacturing, and protecting harnesses, instruments, and lighting from heat, water, dust, or corrosion. Its thin wall promotes quick installation and flexibility. The thin wall also keeps the tubing flexible when flexibility is an issue.
Parflex also offers turnkey services for heat shrink. Even on very difficult applications, like balloon catheters, Parker can cut and score the tubing for easy peel back, ensuring quicker installation and consistency. In addition, outsourcing reduces scrap and allows you to use the product immediately upon receipt without using additional space in your warehouse for carrying inventory.
Markets:
• Industrial
• Medical
• Government
• Electrical
Features/Benefits:
• 2:1 shrink ratio for easy slippage over component
• QPL-approved AS23053/12
• Exceptional heat resistance
• Chemical resistant
• Chemically inert
• When used in electrical insulation, exhibits superior dielectric strength
• Lowest coefficient of friction aids in sliding
• Self-extinguishing
• Non-wetting
Applications:
• Protective covering for components
• Electrical insulation
• Applications where fire hazards are present
• Bulb protection
• Harnesses
• Laboratory
Certifications/Compliance:
• QPL-approved AS23053/12
• ASTM D2902 Type I
• USP Class VI compliant• 21 CFR 177.1550 compliant • UL 94 V-0 compliant
Specifications:
• Recovered wall thickness is nominal
• Shrink Temperature: 662°F/350°C for 10 minutes per AMS-DTL-23053/12A
• Dielectric Strength: > 1,400 V/M, per ASTM D 149 short term test of 10 MIL thickness (Volts/MIL)
•Colors available as custom run
| Action | Part No. | Availability | Partner Available | Price | Division | Size | Specifications Met | Minimum Operating Temperature | Product Style | Minimum Expanded Inside Diameter | Product Type | Recovered Wall Thickness | Length per Package | Tube Material | Maximum Operating Temperature | Color | Recovered Inside Diameter | Weight | Application | Recovered Inside Diameter | Minimum Expanded Inside Diameter | Product Style |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HS2TFS15-NT-SP | Quote Required | TBD | Parflex Division | AWG 15 | ASTM 2902, Type I | -75 | AWG | 0.11 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.067 | 0.0035 | High Temperature Applications | 0.067 | 0.110 | Standard Wall | ||
| HS2TFS16-NT-SP | Quote Required | TBD | Parflex Division | AWG 16 | ASTM 2902, Type I | -75 | AWG | 0.093 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.061 | 0.0033 | High Temperature Applications | 0.061 | 0.093 | Standard Wall | ||
| HS2TFS17-NT-SP | Quote Required | TBD | Parflex Division | AWG 17 | ASTM 2902, Type I | -75 | AWG | 0.085 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.054 | 0.0029 | High Temperature Applications | 0.054 | 0.085 | Standard Wall | ||
| HS2TFS18-NT-SP | Quote Required | TBD | Parflex Division | AWG 18 | ASTM 2902, Type I | -75 | AWG | 0.076 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.049 | 0.0028 | Laboratory | 0.049 | 0.076 | Standard Wall | ||
| HS2TFS19-NT-SP | Quote Required | TBD | Parflex Division | AWG 19 | ASTM 2902, Type I | -75 | AWG | 0.065 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.043 | 0.0024 | High Temperature Applications | 0.043 | 0.065 | Standard Wall | ||
| HS2TFS20-NT-SP | Quote Required | TBD | Parflex Division | AWG 20 | ASTM 2902, Type I | -75 | AWG | 0.06 | Heat Shrink Tubing | 0.41 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.039 | 0.0022 | High Temperature Applications | 0.039 | 0.060 | Standard Wall | ||
| HS2TFS22-NT-SP | Quote Required | TBD | Parflex Division | AWG 22 | ASTM 2902, Type I | -75 | AWG | 0.055 | Heat Shrink Tubing | 0.012 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.032 | 0.0013 | High Temperature Applications | 0.032 | 0.055 | Standard Wall | ||
| HS2TFS24-NT-SP | Quote Required | TBD | Parflex Division | AWG 24 | ASTM 2902, Type I | -75 | AWG | 0.05 | Heat Shrink Tubing | 0.012 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.027 | 0.0011 | High Temperature Applications | 0.027 | 0.050 | Standard Wall | ||
| HS2TFS3/4-NT-SP | Quote Required | TBD | Parflex Division | 3/4 | ASTM 2902, Type I | -75 | Fractional | 28.6 | Heat Shrink Tubing | 0.035 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.786 | 0.0795 | High Temperature Applications | 0.786 | 1.125 | Standard Wall | ||
| HS2TFS3/8-NT-SP | Quote Required | TBD | Parflex Division | 3/8 inch | AS 23053/12 | -100 °F | Fractional | 0.56 inch | Heat Shrink Tubing | 0.64 mm | 30.5 m | Polytetrafluoroethylene (PTFE) | 500 °F | Natural | 10.1 mm | 0.0448 kg/m | Electrical Insulation | 0.399 | 0.560 | Standard Wall | ||
| HS2TFS5/16-NT-SP | Quote Required | TBD | Parflex Division | 5/16 | ASTM 2902, Type I | -75 | Fractional | 11.9 | Heat Shrink Tubing | 0.020 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.329 | 0.019 | High Temperature Applications | 0.329 | 0.470 | Standard Wall | ||
| HS2TFS5/8-NT-SP | Quote Required | TBD | Parflex Division | 5/8 inch | USP Class VI | -100 °F | Fractional | 0.93 inch | 2:1 | 0.76 mm | 100 ft | Polytetrafluoroethylene (PTFE) | 260 °C | Natural | 16.6 mm | 0.0605 lb/ft | Electrical Insulation | 0.655 | 0.930 | Standard Wall | ||
| HS2TFT 3/4-NT-SP | Quote Required | TBD | Parflex Division | 3/4 | ASTM 2902, Type I | -75 | Fractional | 28.6 | Heat Shrink Tubing | 0.64 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.786 | 0.0746 | High Temperature Applications | 0.786 | 1.125 | Thin Wall | ||
| HS2TFT 3/8-NT-SP | Quote Required | TBD | Parflex Division | 3/8 | ASTM 2902, Type I | -75 | Fractional | 14.2 | Heat Shrink Tubing | 0.38 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.399 | 0.0176 | High Temperature Applications | 0.399 | 0.560 | Thin Wall | ||
| HS2TFT 5/8-NT-SP | Quote Required | TBD | Parflex Division | 5/8 | ASTM 2902, Type I | -75 | Fractional | 23.6 | Heat Shrink Tubing | 0.51 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.655 | 0.0375 | High Temperature Applications | 0.655 | 0.930 | Thin Wall | ||
| HS2TFT 7/16-NT-SP | Quote Required | TBD | Parflex Division | 7/16 | ASTM 2902, Type I | -75 | Fractional | 16.6 | Heat Shrink Tubing | 0.46 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.462 | 0.024 | High Temperature Applications | 0.462 | 0.655 | Thin Wall | ||
| HS2TFT 7/8-NT-SP | Quote Required | TBD | Parflex Division | 7/8 | ASTM 2902, Type I | -75 | Fractional | 33.3 | Heat Shrink Tubing | 0.64 | 30.5 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.911 | 0.0795 | Protective Cover | 0.911 | 1.310 | Thin Wall | ||
| HS2TFT00-NT-SP | Quote Required | TBD | Parflex Division | AWG 0 | ASTM 2902, Type I | -75 | AWG | 11.9 | Heat Shrink Tubing | 0.38 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.347 | 0.0148 | High Temperature Applications | 0.347 | 0.470 | Thin Wall | ||
| HS2TFT01-NT-SP | Quote Required | TBD | Parflex Division | AWG 1 | ASTM 2902, Type I | -75 | AWG | 11.4 | Heat Shrink Tubing | 0.38 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.311 | 0.0123 | High Temperature Applications | 0.311 | 0.450 | Thin Wall | ||
| HS2TFT02-NT-SP | Quote Required | TBD | Parflex Division | AWG 2 | ASTM 2902, Type I | -75 | AWG | 10.9 | Heat Shrink Tubing | 0.38 | 100 | Polytetrafluoroethylene (PTFE) | 500 | Natural | 0.278 | 0.0125 | High Temperature Applications | 0.278 | 0.430 | Thin Wall |