- Availability & Price
- Search SKU
Filter by attributes
- Minimum Expanded Inside Diameter
- Product Style
- Recovered Inside Diameter
Filter by manufacturer
Recently viewed products
-
Parker ICEP003-WASP3T0000001 - Hyperchill Plus - Industrial Water Chiller for Precision Cooling of Low Viscosity Industrial Cooling Fluids -
Parker 12FBT12N-6MO-NSK - Parker Tube Fitting, NPT Female Branch Tee - A-LOK Series -
Parker C1MNO150 - FULFLO FILTER BAGS | EXTENSIVE RANGE OF FILTER BAG MEDIA FOR REMOVAL OF SOLIDS IN PROCESS LIQUID FILTRATION APPLICATIONS
QPL PTFE AWG & Fractional 2:1 Heat Shrinkable Tubing
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's QPL-approved AS23053/12 PTFE Heat Shrink Tubing protects components from heat, sparks, and contaminants while handling long-term exposure to temperatures as high as 500°F (260°C). When heated, it conforms to the object's shape, providing a protective covering. PTFE AWG 2:1 and Fractional 2:1 heat shrink is produced in Heavy Wall, Standard Wall, Thin Wall, and Light Wall designs and supplied in an expanded state, allowing easy slippage over cables, fittings, and other protrusions.
PTFE AWG heat shrinkable tubing is typically used when repairing electrical wiring, fittings, cords and other small objects that need to be protected from heat, water, dust or corrosion. Fractional 2:1 heat shrink is used to protect larger objects like electrical harnesses, instruments, or even lighting where a breakage would compromise the operation.
QPL 23053/12 PTFE heat shrink is ideal for repairing electrical wiring, catheter manufacturing, and protecting harnesses, instruments, and lighting from heat, water, dust, or corrosion. Its thin wall promotes quick installation and flexibility. The thin wall also keeps the tubing flexible when flexibility is an issue.
Parflex also offers turnkey services for heat shrink. Even on very difficult applications, like balloon catheters, Parker can cut and score the tubing for easy peel back, ensuring quicker installation and consistency. In addition, outsourcing reduces scrap and allows you to use the product immediately upon receipt without using additional space in your warehouse for carrying inventory.
Markets:
• Industrial
• Medical
• Government
• Electrical
Features/Benefits:
• 2:1 shrink ratio for easy slippage over component
• QPL-approved AS23053/12
• Exceptional heat resistance
• Chemical resistant
• Chemically inert
• When used in electrical insulation, exhibits superior dielectric strength
• Lowest coefficient of friction aids in sliding
• Self-extinguishing
• Non-wetting
Applications:
• Protective covering for components
• Electrical insulation
• Applications where fire hazards are present
• Bulb protection
• Harnesses
• Laboratory
Certifications/Compliance:
• QPL-approved AS23053/12
• ASTM D2902 Type I
• USP Class VI compliant• 21 CFR 177.1550 compliant • UL 94 V-0 compliant
Specifications:
• Recovered wall thickness is nominal
• Shrink Temperature: 662°F/350°C for 10 minutes per AMS-DTL-23053/12A
• Dielectric Strength: > 1,400 V/M, per ASTM D 149 short term test of 10 MIL thickness (Volts/MIL)
•Colors available as custom run
Read More...PTFE AWG heat shrinkable tubing is typically used when repairing electrical wiring, fittings, cords and other small objects that need to be protected from heat, water, dust or corrosion. Fractional 2:1 heat shrink is used to protect larger objects like electrical harnesses, instruments, or even lighting where a breakage would compromise the operation.
QPL 23053/12 PTFE heat shrink is ideal for repairing electrical wiring, catheter manufacturing, and protecting harnesses, instruments, and lighting from heat, water, dust, or corrosion. Its thin wall promotes quick installation and flexibility. The thin wall also keeps the tubing flexible when flexibility is an issue.
Parflex also offers turnkey services for heat shrink. Even on very difficult applications, like balloon catheters, Parker can cut and score the tubing for easy peel back, ensuring quicker installation and consistency. In addition, outsourcing reduces scrap and allows you to use the product immediately upon receipt without using additional space in your warehouse for carrying inventory.
Markets:
• Industrial
• Medical
• Government
• Electrical
Features/Benefits:
• 2:1 shrink ratio for easy slippage over component
• QPL-approved AS23053/12
• Exceptional heat resistance
• Chemical resistant
• Chemically inert
• When used in electrical insulation, exhibits superior dielectric strength
• Lowest coefficient of friction aids in sliding
• Self-extinguishing
• Non-wetting
Applications:
• Protective covering for components
• Electrical insulation
• Applications where fire hazards are present
• Bulb protection
• Harnesses
• Laboratory
Certifications/Compliance:
• QPL-approved AS23053/12
• ASTM D2902 Type I
• USP Class VI compliant• 21 CFR 177.1550 compliant • UL 94 V-0 compliant
Specifications:
• Recovered wall thickness is nominal
• Shrink Temperature: 662°F/350°C for 10 minutes per AMS-DTL-23053/12A
• Dielectric Strength: > 1,400 V/M, per ASTM D 149 short term test of 10 MIL thickness (Volts/MIL)
•Colors available as custom run
| Action | Part No. | Availability | Partner Available | Price | Length per Package | Weight | Recovered Inside Diameter | Maximum Operating Temperature | Tube Material | Color | Application | Division | Specifications Met | Recovered Wall Thickness | Product Style | Minimum Operating Temperature | Minimum Expanded Inside Diameter | Product Type | Size | Recovered Inside Diameter | Product Style | Minimum Expanded Inside Diameter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HS2TFS 7/8-NT-SP | Quote Required | TBD | 30.5 | 0.0921 | 0.911 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.89 | Fractional | -75 | 28.7 | Heat Shrink Tubing | 7/8 | 0.911 | Standard Wall | 1.130 | ||
| HS2TFS00-NT-SP | Quote Required | TBD | 100 ft | 0.0203 lb/ft | 8.81 mm | 260 °C | Polytetrafluoroethylene (PTFE) | Natural | Electrical Insulation | Parflex Division | AS 23053/12 | 0.020 inch | AWG | -100 °F | 0.47 inch | 2:1 | AWG 0 | 0.347 | Standard Wall | 0.470 | ||
| HS2TFS01-NT-SP | Quote Required | TBD | 100 | 0.0186 | 0.311 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.45 | Heat Shrink Tubing | AWG 1 | 0.311 | Standard Wall | 0.450 | ||
| HS2TFS02-NT-SP | Quote Required | TBD | 100 | 0.0167 | 0.278 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.43 | Heat Shrink Tubing | AWG 2 | 0.278 | Standard Wall | 0.430 | ||
| HS2TFS03-NT-SP | Quote Required | TBD | 100 | 0.015 | 0.249 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.39 | Heat Shrink Tubing | AWG 3 | 0.249 | Standard Wall | 0.39 | ||
| HS2TFS04-NT-SP | Quote Required | TBD | 100 | 0.0114 | 5.69 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.37 | Heat Shrink Tubing | AWG 4 | 0.224 | Standard Wall | 0.37 | ||
| HS2TFS05-NT-SP | Quote Required | TBD | 30.5 m | 0.0198 kg/m | 5.03 mm | 260 °C | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | UL 94 V-0 | 0.51 mm | AWG | -100 °F | 8.13 mm | 2:1 | AWG 5 | 0.198 | Standard Wall | 0.320 | ||
| HS2TFS06-NT-SP | Quote Required | TBD | 100 | 0.0107 | 0.178 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.302 | Heat Shrink Tubing | AWG 6 | 0.178 | Standard Wall | 0.302 | ||
| HS2TFS07-NT-SP | Quote Required | TBD | 100 | 0.0097 | 0.158 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.27 | Heat Shrink Tubing | AWG 7 | 0.158 | Standard Wall | 0.270 | ||
| HS2TFS08-NT-SP | Quote Required | TBD | 100 | 0.0099 | 0.141 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.24 | Heat Shrink Tubing | AWG 8 | 0.141 | Standard Wall | 0.240 | ||
| HS2TFS09-NT-SP | Quote Required | TBD | 100 | 0.0075 | 0.124 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.51 | AWG | -75 | 0.205 | Heat Shrink Tubing | AWG 9 | 0.124 | Standard Wall | 0.205 | ||
| HS2TFS1.00-NT-SP | Quote Required | TBD | 100 | 0.104 | 1.036 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.89 | Fractional | -75 | 38.1 | Heat Shrink Tubing | 1 | 1.036 | Standard Wall | 1.500 | ||
| HS2TFS1/2-NT-SP | Quote Required | TBD | 100 | 0.0377 | 0.524 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.025 | Fractional | -75 | 19.1 | Heat Shrink Tubing | 1/2 | 0.524 | Standard Wall | 0.750 | ||
| HS2TFS1/4-NT-SP | Quote Required | TBD | 100 | 0.0158 | 0.260 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.020 | Fractional | -75 | 10.4 | Heat Shrink Tubing | 1/4 | 0.260 | Standard Wall | 0.410 | ||
| HS2TFS1/8-NT-SP | Quote Required | TBD | 100 | 0.0085 | 0.130 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.020 | Fractional | -75 | 5.5 | Heat Shrink Tubing | 1/8 | 0.130 | Standard Wall | 0.215 | ||
| HS2TFS10-NT-SP | Quote Required | TBD | 100 | 0.0055 | 0.112 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.41 | AWG | -75 | 0.191 | Heat Shrink Tubing | AWG 10 | 0.112 | Standard Wall | 0.191 | ||
| HS2TFS11-NT-SP | Quote Required | TBD | 100 | 0.005 | 0.101 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.41 | AWG | -75 | 0.17 | Heat Shrink Tubing | AWG 11 | 0.101 | Standard Wall | 0.170 | ||
| HS2TFS12-NT-SP | Quote Required | TBD | 100 | 0.0044 | 0.089 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.41 | AWG | -75 | 0.15 | Heat Shrink Tubing | AWG 12 | 0.089 | Standard Wall | 0.150 | ||
| HS2TFS13-NT-SP | Quote Required | TBD | 100 | 0.0041 | 0.080 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.41 | AWG | -75 | 0.14 | Heat Shrink Tubing | AWG 13 | 0.08 | Standard Wall | 0.140 | ||
| HS2TFS14-NT-SP | Quote Required | TBD | 100 | 0.0038 | 0.072 | 500 | Polytetrafluoroethylene (PTFE) | Natural | High Temperature Applications | Parflex Division | ASTM 2902, Type I | 0.41 | AWG | -75 | 0.12 | Heat Shrink Tubing | AWG 14 | 0.072 | Standard Wall | 0.120 |