- Availability & Price
- Search SKU
Filter by attributes
- Order Size
- Product Type
- Standard Pack Qty (ft)
- Tube Inside Diameter
- Tube Wall Thickness
Filter by manufacturer
PTFE AWG Tubing
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
PTFE AWG Tubing for electrical insulation applicationsis most often used in electrical insulation applications. A PTFE tube has a non-stick surface that eliminates media buildup. In electrical applications, AWG tubing is placed over wire/cable as a protective cover that prevents electrical discharge and heat dissipation. PTFE AWG Tubing is sometimes referred to as “Spaghetti Tubing” or “American Wire Gauge Tubing”. It is supplied in natural and available as a custom run in ten different colors. Tubing is available in Standard Wall, Light Wall, Thin Wall and Heavy Wall designs and is the best chemical resistant tubing Parker offers.
Markets:
• Electrical
• Life Science
• Industrial
Features/Benefits:
• Exceptional resistance to extreme heat or cold
• Best chemical and corrosion resistance
• Lowest coefficient of friction of all plastics
• Superior dielectric strength
• Non-wetting and non-leaching
• Odorless and tasteless makes it ideal for food and beverage applications
• Excellent flex life
• Laser markable
• Resists ultra-violet rays
• Self-extinguishing plastic
Applications:
• Electrical insulation
• Circuit boards
• Wire insulation
• Protective covering
• Strain relief
• Introducer
• Stent delivery
• Cable liner
• Spacer
Certifications/Compliance:
• AMS 3653
• 21 CFR 177.1550 Compliant
• USP Class VI Compliant
• Light Wall (TFL) – ASTM D3295 Class 1
• Thin Wall (TFT) – ASTM D3295 Class 2, AMS 3655, CSA 9032-01 300V
• Standard Wall (TFS) - CSA 9032-01 600V
• Heavy Wall (TFH) – ASTM D3295, Class 4
Technical Specifications:
• Extruded from virgin PTFE (Polytetrafluoroethylene)
• Chemical Resistance: Fluoropolymers withstand most chemicals and solvents except for Elemental Sodium, Elemental Potassium, and Elemental Lithium. Elemental Sodium will remove the fluorine from the polymer molecule and the other metals have a similar affect.
• All dimensions are nominal
• Continuous lengths and colors available as a custom run - Contact customer service
• Qualified with fittings from Parker Fluid System Connectors Division Fittings (See Brass Composite and Thermoplastic Fittings and Valves Catalog CAT3501E USA)
Read More...Markets:
• Electrical
• Life Science
• Industrial
Features/Benefits:
• Exceptional resistance to extreme heat or cold
• Best chemical and corrosion resistance
• Lowest coefficient of friction of all plastics
• Superior dielectric strength
• Non-wetting and non-leaching
• Odorless and tasteless makes it ideal for food and beverage applications
• Excellent flex life
• Laser markable
• Resists ultra-violet rays
• Self-extinguishing plastic
Applications:
• Electrical insulation
• Circuit boards
• Wire insulation
• Protective covering
• Strain relief
• Introducer
• Stent delivery
• Cable liner
• Spacer
Certifications/Compliance:
• AMS 3653
• 21 CFR 177.1550 Compliant
• USP Class VI Compliant
• Light Wall (TFL) – ASTM D3295 Class 1
• Thin Wall (TFT) – ASTM D3295 Class 2, AMS 3655, CSA 9032-01 300V
• Standard Wall (TFS) - CSA 9032-01 600V
• Heavy Wall (TFH) – ASTM D3295, Class 4
Technical Specifications:
• Extruded from virgin PTFE (Polytetrafluoroethylene)
• Chemical Resistance: Fluoropolymers withstand most chemicals and solvents except for Elemental Sodium, Elemental Potassium, and Elemental Lithium. Elemental Sodium will remove the fluorine from the polymer molecule and the other metals have a similar affect.
• All dimensions are nominal
• Continuous lengths and colors available as a custom run - Contact customer service
• Qualified with fittings from Parker Fluid System Connectors Division Fittings (See Brass Composite and Thermoplastic Fittings and Valves Catalog CAT3501E USA)
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Temperature | Tube Material | Size | Specifications Met | Tube Outside Diameter | Media | Color | Minimum Operating Temperature | Application | Length per Package | Weight | Tube Inside Diameter | Compatible Fitting | Product Type | Standard Pack Qty (ft) | Tube Inside Diameter | Order Size | Tube Wall Thickness |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TFH05-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 5 | AMS 3653G | 6.3 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | Random Length Coils | 0.0203 | 0.185 | TrueSeal™ | Obsolete AWG | random length coils | 0.185 | AWG05 Heavy Wall | 0.032 | ||
| TFH06-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 6 | AMS 3653G | 0.226 | Chemicals | Natural (colors available upon request) | -100 | Electrical Insulation | Random Length Coils | 0.0172 | 0.166 | TrueSeal™ | Obsolete AWG | random length coils | 0.166 | AWG06 Heavy Wall | 0.03 | ||
| TFH07-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 7 | AMS 3653G | 0.208 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | Random Length Coils | 0.0156 | 0.148 | TrueSeal™ | Obsolete AWG | random length coils | 0.148 | AWG07 Heavy Wall | 0.03 | ||
| TFH08-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 8 | AMS 3653G | 4.9 | Chemicals | Natural (colors available upon request) | -100 | Electrical Insulation | Random Length Coils | 0.0143 | 0.133 | TrueSeal™ | Obsolete AWG | random length coils | 0.133 | AWG08 Heavy Wall | 0.03 | ||
| TFH09-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 9 | AMS 3653G | 0.168 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 170 m Spool | 0.0105 | 0.118 | TrueSeal™ | Obsolete AWG | 500 ft. spool | 0.118 | AWG09 Heavy Wall | 0.025 | ||
| TFH10-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 10 | AMS 3653G | 3.9 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 170 m Spool | 0.0096 | 0.106 | TrueSeal™ | Obsolete AWG | 500 ft. spool | 0.106 | AWG10 Heavy Wall | 0.025 | ||
| TFH11-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 11 | AMS 3653G | 3.4 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 170 m Spool | 0.0067 | 0.095 | TrueSeal™ | Obsolete AWG | 500 ft. spool | 0.095 | AWG11 Heavy Wall | 0.02 | ||
| TFH12-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 12 | AMS 3653G | 3 | Chemicals | Natural (colors available upon request) | -100 | Electrical Insulation | 500 | 0.0061 | 0.085 | n/a | Obsolete AWG | 500 ft. spool | 0.085 | AWG12 Heavy Wall | 0.02 | ||
| TFH13-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 13 | AMS 3653G | 0.116 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 500 | 0.0056 | 0.076 | n/a | Obsolete AWG | 500 ft. spool | 0.076 | AWG13 Heavy Wall | 0.02 | ||
| TFH14-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 14 | AMS 3653G | 2.7 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 500 | 0.0074 | 0.066 | n/a | Obsolete AWG | 500 ft. spool | 0.066 | AWG14 Heavy Wall | 0.02 | ||
| TFH15-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 15 | AMS 3653G | 2.5 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0046 | 0.059 | n/a | Obsolete AWG | 1,000 ft. spool | 0.059 | AWG15 Heavy Wall | 0.02 | ||
| TFH16-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 16 | AMS 3653G | 2.4 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0043 | 1.3 | n/a | Obsolete AWG | 1,000 ft. spool | 0.053 | AWG16 Heavy Wall | 0.02 | ||
| TFH17-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 17 | AMS 3653G | 0.088 | Chemicals | Natural (colors available upon request) | -100 | Electrical Insulation | 1000 | 0.004 | 1.2 | n/a | Obsolete AWG | 1,000 ft. spool | 0.048 | AWG17 Heavy Wall | 0.02 | ||
| TFH18-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 18 | AMS 3653G | 0.082 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0036 | 2 | n/a | Obsolete AWG | 1,000 ft. spool | 0.042 | AWG18 Heavy Wall | 0.02 | ||
| TFH19-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 19 | AMS 3653G | 2 | Chemicals | Natural (colors available upon request) | -100 | Electrical Insulation | 1000 | 0.0034 | 1 | n/a | Obsolete AWG | 1,000 ft. spool | 0.038 | AWG19 Heavy Wall | 0.02 | ||
| TFH20-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 20 | AMS 3653G | 1.8 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0027 | 0.91 | n/a | Obsolete AWG | 1,000 ft. spool | 0.034 | AWG20 Heavy Wall | 0.018 | ||
| TFH21-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 21 | AMS 3653G | 1.6 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0022 | 0.81 | n/a | Obsolete AWG | 1,000 ft. spool | 0.032 | AWG21 Heavy Wall | 0.016 | ||
| TFH22-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 22 | AMS 3653G | 0.060 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0021 | 0.71 | n/a | Obsolete AWG | 1,000 ft. spool | 0.028 | AWG22 Heavy Wall | 0.016 | ||
| TFH23-NT | Quote Required | TBD | 260 | Polytetrafluoroethylene (PTFE) | AWG 23 | AMS 3653G | 1.5 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.003 | 0.026 | n/a | Obsolete AWG | 1,000 ft. spool | 0.026 | AWG23 Heavy Wall | 0.016 | ||
| TFH24-NT | Quote Required | TBD | 500 | Polytetrafluoroethylene (PTFE) | AWG 24 | AMS 3653G | 1.4 | Chemicals | Natural (colors available upon request) | -75 | Electrical Insulation | 1000 | 0.0018 | 0.022 | n/a | Obsolete AWG | 1,000 ft. spool | 0.022 | AWG24 Heavy Wall | 0.016 |