- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Priority Flow
- Pressure Differential
- Seal Material
Filter by manufacturer
Recently viewed products
Priority Pressure Compensators
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s family of priority pressure compensator valves feature a robust and contamination tolerant design that ensures consistent flow regardless of up or down stream pressures while providing priority to one outlet port. These valves can operate with hydraulic system flows as high as 95 lpm and pressures up to 380 bar with a variety of differential pressure setting and adjustment options. Parker’s pressure compensator valves are ideal for constant and consistent flow applications that contain functions that requires priority such as conveyors or saws within mobile, industrial, or manufacturing markets.
Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Contamination tolerant
• Stable and quiet response
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Conveyors
• Steering applications
• Saws
• Constant and consistent flow applications
Additional Technical Insight:
Flow through the external orifice (fixed or variable) enters the supply port and produces a pressure drop across the compensator spool. When the inlet pressure exceeds the initial setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle, or restrict, the flow, thus maintaining constant flow through the priority port. The excess flow is bypassed out to the system to be used by another function, or back to the system reservoir. Flow out the regulated port must be maintained for bypass flow to continue. For this reason, common practice dictates a pressure control (relief) be installed in the priority line.
Read More...Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• Contamination tolerant
• Stable and quiet response
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Conveyors
• Steering applications
• Saws
• Constant and consistent flow applications
Additional Technical Insight:
Flow through the external orifice (fixed or variable) enters the supply port and produces a pressure drop across the compensator spool. When the inlet pressure exceeds the initial setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle, or restrict, the flow, thus maintaining constant flow through the priority port. The excess flow is bypassed out to the system to be used by another function, or back to the system reservoir. Flow out the regulated port must be maintained for bypass flow to continue. For this reason, common practice dictates a pressure control (relief) be installed in the priority line.
| Action | Part No. | Availability | Partner Available | Price | UOM | Pressure Differential | Flow Rate | Adjustment Mechanism | Flow Rate Accuracy | Filter Efficiency Rating | Seal Material | Division | Maximum Flow Rate | Maximum Operating Temperature | Body Material | Weight | Maximum Priority Flow | Division | Valve Material | Actuation Type | Maximum Inlet Pressure Rating | Cavity Size | Minimum Operating Temperature | Operating Temperature | Maximum Kinematic Viscosity | Function | For Fluid Type | Installation Torque | Maximum Operating Pressure | Maximum Flow Rate | Pressure Differential | Seal Material | Maximum Priority Flow |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FCP101F | Quote Required | $86.44 | EA | 160 psi | 56 L/min | Fixed | 10% | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 56 L/min | +121 °C | n/a | 0.14 kg | 10 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 245 bar | C10-4 | -30 °F | -30 to +250 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 16 lb-ft | 3500 psi | 15 GAL/MIN, 56 L/MIN | 160 PSI, 11 BAR | Nitrile | 10 GAL/MIN, 38 L/MIN | ||
| FCP101F04 | Quote Required | TBD | 2.8 bar | 56 L/min | Fixed | 10% | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 56 L/min | +121 °C | n/a | 0.3 lb | 10 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 245 bar | C10-4 | -30 °F | -34 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 22 Nm | 3500 psi | 15 GAL/MIN, 56 L/MIN | 40 PSI, 2.8 BAR | Nitrile | 10 GAL/MIN, 38 L/MIN | |||
| FCP101F08 | Quote Required | TBD | 80 psi | 15 Gal/min | Fixed | 10% | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 56 L/min | +250 °F | n/a | 0.3 lb | 38 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 245 bar | C10-4 | -34 °C | -34 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 22 Nm | 3500 psi | 15 GAL/MIN, 56 L/MIN | 80 PSI, 5.5 BAR | Nitrile | 10 GAL/MIN, 38 L/MIN | |||
| FCP101F08V | Quote Required | TBD | 80 psi | 15 Gal/min | Fixed | 10% | ISO 4406 18/16/13, SAE Class 4 | Fluorocarbon | Hydraulic Systems Division | 56 L/min | +204 °C | n/a | 0.3 lb | 10 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 245 bar | C10-4 | -15 °F | -26 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 22 Nm | 3500 psi | 15 GAL/MIN, 56 L/MIN | 80 PSI, 5.5 BAR | Fluorocarbon | 10 GAL/MIN, 38 L/MIN | |||
| FCP101FV | Quote Required | TBD | 160 psi | 15 Gal/min | Fixed | 10% | ISO 4406 18/16/13, SAE Class 4 | Fluorocarbon | Hydraulic Systems Division | 56 L/min | +400 °F | n/a | 0.14 kg | 38 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 245 bar | C10-4 | -15 °F | -15 to +400 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 22 Nm | 245 bar | 15 GAL/MIN, 56 L/MIN | 160 PSI, 11 BAR | Fluorocarbon | 10 GAL/MIN, 38 L/MIN | |||
| FCPH121F | Quote Required | TBD | 160 psi | 95 L/min | Fixed | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 95 L/min | +121 °C | n/a | 0.62 lb | 75 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 5500 psi | C12-4 | -30 °F | -34 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 29 Nm | 380 bar | 25 GAL/MIN, 95 L/MIN | 160 PSI, 11 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121F04 | Quote Required | TBD | 2.8 bar | 95 L/min | Fixed | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 25 Gal/min | +121 °C | n/a | 0.28 kg | 20 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 5500 psi | C12-4 | -30 °F | -30 to +250 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 lb-ft | 380 bar | 25 GAL/MIN, 95 L/MIN | 40 PSI, 2.8 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121F24 | Quote Required | TBD | 16.6 bar | 25 Gal/min | Fixed | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 95 L/min | +250 °F | n/a | 0.62 lb | 20 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 5500 psi | C12-4 | -34 °C | -34 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 29 Nm | 5500 psi | 25 GAL/MIN, 95 L/MIN | 240 PSI, 16.6 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121FV | Quote Required | TBD | 11 bar | 95 L/min | Fixed | N/A | ISO 4406 18/16/13, SAE Class 4 | Fluorocarbon | Hydraulic Systems Division | 25 Gal/min | +204 °C | n/a | 0.28 kg | 20 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 380 bar | C12-4 | -15 °F | -15 to +400 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 lb-ft | 380 bar | 25 GAL/MIN, 95 L/MIN | 160 PSI, 11 BAR | Fluorocarbon | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121K | Quote Required | TBD | 160 | 25 | Knob | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 25 | +250 | n/a | 0.62 | 20 | Hydraulic Valve Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 5500 | C12-4 | -30 | -30 to +250 | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 | 5500 | 25 GAL/MIN, 95 L/MIN | 160 PSI, 11 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121K08 | Quote Required | TBD | 80 psi | 25 Gal/min | Knob | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 25 Gal/min | +250 °F | n/a | 0.62 lb | 75 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 5500 psi | C12-4 | -30 °F | -34 to +204 °C | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 lb-ft | 5500 psi | 25 GAL/MIN, 95 L/MIN | 80 PSI, 5.5 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121S | Quote Required | TBD | 11 bar | 25 Gal/min | Screw | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 95 L/min | +250 °F | n/a | 0.28 kg | 75 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 380 bar | C12-4 | -34 °C | -30 to +250 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 lb-ft | 380 bar | 25 GAL/MIN, 95 L/MIN | 160 PSI, 11 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121S08 | Quote Required | TBD | 5.5 bar | 25 Gal/min | Screw | N/A | ISO 4406 18/16/13, SAE Class 4 | Nitrile | Hydraulic Systems Division | 25 Gal/min | +250 °F | n/a | 0.28 kg | 20 Gal/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 380 bar | C12-4 | -34 °C | -30 to +250 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 21 lb-ft | 5500 psi | 25 GAL/MIN, 95 L/MIN | 80 PSI, 5.5 BAR | Nitrile | 20 GAL/MIN, 75 L/MIN | |||
| FCPH121SV | Quote Required | TBD | 11 bar | 95 L/min | Screw | N/A | ISO 4406 18/16/13, SAE Class 4 | Fluorocarbon | Hydraulic Systems Division | 25 Gal/min | +204 °C | n/a | 0.62 lb | 75 L/min | Hydraulic Cartridge Systems Division | All parts steel. All operating parts hardened steel | Pressure Compensation | 380 bar | C12-4 | -15 °F | -15 to +400 °F | 45-2000 SSU (6 to 420 cSt) | Priority Pressure Compensators | Mineral-based or synthetic hydraulic fluids | 29 Nm | 5500 psi | 25 GAL/MIN, 95 L/MIN | 160 PSI, 11 BAR | Fluorocarbon | 20 GAL/MIN, 75 L/MIN |