- Availability & Price
- Search SKU
Filter by attributes
- Adjustment Mechanism
- Flow Rate
- Pressure Control Range
- Seal Material
Filter by manufacturer
Pilot Operated Sequence Valve with Kickdown
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s kick-down pilot operated sequence valve provides fast responding and reliable performance for hydraulic circuits that require pressure to be eliminated once the max setting is achieved. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 160 lpm (42 gpm) and can be considered a hydraulic fuse. Parker’s kick-down pilot operated sequence valve is intended for clamping or press within industrial markets, but can also be use in mobile applications such as when attachments are used with quick disconnects and a fixed displacement pump.
Markets:
• Agriculture
• Aerial
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High pressure and flow capacity
• Integrated 250 micron screen
• Hardened, precision ground parts for durability
• All external parts zinc plated
Applications:
• Clamping
• Power units
• Attachments/implements with quick disconnects
Additional Technical Insight:
Unlike relief valves which will reset slightly below their pressure setting, Parker’s B04C3 Kick-Down sequence valve will continue to unload pump flow until its supply flow is completely stopped. Two adjustable pressure ranges are standard for 3000 or 6000 PSI maximum operating pressures, and each version is capable of flows up to 42 GPM. Screw, knob, and tamper-resistant adjustment options are available.
B04C3 pilot operated cartridges are normally closed, internally piloted and externally drained. The external drain prevents downstream pressure from having an effect on the valve setting. When inlet pressure at port 1 is lower than the valve’s setting, flow is not allowed to exit port 2. Once the pressure setting is reached, flow from port 1 is unloaded to port 2. The valve does not reset and close until flow is completely removed from port 1. Staying open after the setting is reached creates a requirement for an operator or the system controls to take steps of removing flow before the valve can stop unloading the pump. Functioning in a manner similar to a fuse can provide additional over-pressurization protection and can also help to detect unusual high pressure machine conditions.
Read More...Markets:
• Agriculture
• Aerial
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High pressure and flow capacity
• Integrated 250 micron screen
• Hardened, precision ground parts for durability
• All external parts zinc plated
Applications:
• Clamping
• Power units
• Attachments/implements with quick disconnects
Additional Technical Insight:
Unlike relief valves which will reset slightly below their pressure setting, Parker’s B04C3 Kick-Down sequence valve will continue to unload pump flow until its supply flow is completely stopped. Two adjustable pressure ranges are standard for 3000 or 6000 PSI maximum operating pressures, and each version is capable of flows up to 42 GPM. Screw, knob, and tamper-resistant adjustment options are available.
B04C3 pilot operated cartridges are normally closed, internally piloted and externally drained. The external drain prevents downstream pressure from having an effect on the valve setting. When inlet pressure at port 1 is lower than the valve’s setting, flow is not allowed to exit port 2. Once the pressure setting is reached, flow from port 1 is unloaded to port 2. The valve does not reset and close until flow is completely removed from port 1. Staying open after the setting is reached creates a requirement for an operator or the system controls to take steps of removing flow before the valve can stop unloading the pump. Functioning in a manner similar to a fuse can provide additional over-pressurization protection and can also help to detect unusual high pressure machine conditions.
| Action | Part No. | Availability | Partner Available | Price | Seal Material | Body Material | Minimum Operating Temperature | Flow Rate | Division | Cavity Size | For Fluid Type | Pilot Location | Valve Material | Filter Efficiency Rating | Maximum Kinematic Viscosity | Maximum Operating Temperature | Maximum Operating Pressure | Weight | Mounting Type | Actuation Type | Maximum Pressure Setting | Division | Operation Type | Adjustment Mechanism | Maximum Tank Pressure | Operating Temperature | Pressure Control Range | Pressure Control Sensitivity | Maximum Inlet Pressure Rating | Leak Rate | Configuration | Maximum Flow Rate | Installation Torque | Standard Setting Pressure | Function | Drain Option | Seal Material | Adjustment Mechanism | Pressure Control Range | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B04C3HTN | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 250 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 3000 | Mobile Hydraulic Systems Division Europe | Automatic | Tamper Resistant | 6000 | -30 to 250 | 145 to 3000 | 435 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 1450 | Pilot Operated Sequence | External | Nitrile | Tamper Resistant | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3HTV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 3000 | Mobile Hydraulic Systems Division Europe | Automatic | Tamper Resistant | 6000 | -15 to 400 | 145 to 3000 | 435 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 1450 | Pilot Operated Sequence | External | Fluorocarbon | Tamper Resistant | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3HWN | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 250 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 3000 | Mobile Hydraulic Systems Division Europe | Automatic | Knob | 6000 | -30 to 250 | 145 to 3000 | 435 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 1450 | Pilot Operated Sequence | External | Nitrile | Knob | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3HWV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 3000 | Mobile Hydraulic Systems Division Europe | Automatic | Knob | 6000 | -15 to 400 | 145 to 3000 | 435 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 1450 | Pilot Operated Sequence | External | Fluorocarbon | Knob | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3HZN | Quote Required | TBD | Nitrile | n/a | -30 °F | 160 L/min | Hydraulic Cartridge Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Hardened Steel (all operating parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 121 °C | 420 bar | 0.55 lb | Screw-in Cartridge | Pressure Sensing | 210 bar | Mobile Hydraulic Systems Division Europe | Automatic | Screw | 6000 psi | -30 to 250 °F | 10 to 210 bar | 30 bar Per Turn | 420 bar | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 Gal/min | 50 Nm | 100 bar | Pilot Operated Sequence | External | Nitrile | Screw | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3HZV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 3000 | Mobile Hydraulic Systems Division Europe | Automatic | Screw | 6000 | -15 to 400 | 145 to 3000 | 435 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 1450 | Pilot Operated Sequence | External | Fluorocarbon | Screw | 145-3000 PSI, 10-210 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PTN | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 250 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 6000 | Mobile Hydraulic Systems Division Europe | Automatic | Tamper Resistant | 6000 | -30 to 250 | 145 to 6000 | 800 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 2900 | Pilot Operated Sequence | External | Nitrile | Tamper Resistant | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PTV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 6000 | Mobile Hydraulic Systems Division Europe | Automatic | Tamper Resistant | 6000 | -15 to 400 | 145 to 6000 | 800 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 2900 | Pilot Operated Sequence | External | Fluorocarbon | Tamper Resistant | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PWN | Quote Required | TBD | Nitrile | n/a | -30 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 250 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 6000 | Mobile Hydraulic Systems Division Europe | Automatic | Knob | 6000 | -30 to 250 | 145 to 6000 | 800 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 2900 | Pilot Operated Sequence | External | Nitrile | Knob | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PWV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 6000 | Mobile Hydraulic Systems Division Europe | Automatic | Knob | 6000 | -15 to 400 | 145 to 6000 | 800 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 2900 | Pilot Operated Sequence | External | Fluorocarbon | Knob | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PZN | Quote Required | TBD | Nitrile | n/a | -30 °F | 160 L/min | Hydraulic Cartridge Systems Division | C10-3S | Mineral-based Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 250 °F | 420 bar | 0.27 kg | Screw-in Cartridge | Pressure Sensing | 420 bar | Mobile Hydraulic Systems Division Europe | Automatic | Screw | 420 bar | -30 to 250 °F | 10 to 420 bar | 800 psi Per Turn | 420 bar | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 160 L/min | 50 Nm | 2900 psi | Pilot Operated Sequence | External | Nitrile | Screw | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN | ||
| B04C3PZV | Quote Required | TBD | Fluorocarbon | n/a | -15 | 42 | Hydraulic Valve Systems Division | C10-3S | Synthetic Hydraulic Fluids | Internal | Steel (all parts) | SAE Class 4 | 45-2000 SSU (6 to 420 cSt) | 400 | 6000 | 0.55 | Screw-in Cartridge | Pressure Sensing | 6000 | Mobile Hydraulic Systems Division Europe | Automatic | Screw | 6000 | -15 to 400 | 145 to 6000 | 800 psi Per Turn | 6000 | 100 cm3/min @ 1450 Psi (100 bar) | Kick Down | 42 | 37 | 2900 | Pilot Operated Sequence | External | Fluorocarbon | Screw | 145-6000 PSI, 10-420 BAR | 42 GAL/MIN, 160 L/MIN |