• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Mechanism
  • Flow Rate
  • Pressure Control Range
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Pilot Operated Sequence Valve with Kickdown

Picture for category Pilot Operated Sequence Valve with Kickdown

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s kick-down pilot operated sequence valve provides fast responding and reliable performance for hydraulic circuits that require pressure to be eliminated once the max setting is achieved. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 160 lpm (42 gpm) and can be considered a hydraulic fuse. Parker’s kick-down pilot operated sequence valve is intended for clamping or press within industrial markets, but can also be use in mobile applications such as when attachments are used with quick disconnects and a fixed displacement pump.

Markets:
• Agriculture
• Aerial
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Integrated 250 micron screen
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• Clamping
• Power units
• Attachments/implements with quick disconnects

Additional Technical Insight:
Unlike relief valves which will reset slightly below their pressure setting, Parker’s B04C3 Kick-Down sequence valve will continue to unload pump flow until its supply flow is completely stopped.  Two adjustable pressure ranges are standard for 3000 or 6000 PSI maximum operating pressures, and each version is capable of flows up to 42 GPM.   Screw, knob, and tamper-resistant adjustment options are available.

B04C3 pilot operated cartridges are normally closed, internally piloted and externally drained.   The external drain prevents downstream pressure from having an effect on the valve setting.  When inlet pressure at port 1 is lower than the valve’s setting, flow is not allowed to exit port 2.  Once the pressure setting is reached, flow from port 1 is unloaded to port 2.  The valve does not reset and close until flow is completely removed from port 1.  Staying open after the setting is reached creates a requirement for an operator or the system controls to take steps of removing flow before the valve can stop unloading the pump.  Functioning in a manner similar to a fuse can provide additional over-pressurization protection and can also help to detect unusual high pressure machine conditions.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialBody MaterialMinimum Operating TemperatureFlow RateDivisionCavity SizeFor Fluid TypePilot LocationValve MaterialFilter Efficiency RatingMaximum Kinematic ViscosityMaximum Operating TemperatureMaximum Operating PressureWeightMounting TypeActuation TypeMaximum Pressure SettingDivisionOperation TypeAdjustment MechanismMaximum Tank PressureOperating TemperaturePressure Control RangePressure Control SensitivityMaximum Inlet Pressure RatingLeak RateConfigurationMaximum Flow RateInstallation TorqueStandard Setting PressureFunctionDrain OptionSeal MaterialAdjustment MechanismPressure Control RangeFlow Rate
B04C3HTN
Quote Required
TBD
Nitrilen/a-3042Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25060000.55Screw-in CartridgePressure Sensing3000Mobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 250145 to 3000435 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42371450Pilot Operated SequenceExternalNitrileTamper Resistant145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3HTV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing3000Mobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 400145 to 3000435 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42371450Pilot Operated SequenceExternalFluorocarbonTamper Resistant145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3HWN
Quote Required
TBD
Nitrilen/a-3042Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25060000.55Screw-in CartridgePressure Sensing3000Mobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 250145 to 3000435 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42371450Pilot Operated SequenceExternalNitrileKnob145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3HWV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing3000Mobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 400145 to 3000435 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42371450Pilot Operated SequenceExternalFluorocarbonKnob145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3HZN
Quote Required
TBD
Nitrilen/a-30 °F160 L/minHydraulic Cartridge Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalHardened Steel (all operating parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C420 bar0.55 lbScrew-in CartridgePressure Sensing210 barMobile Hydraulic Systems Division EuropeAutomaticScrew6000 psi-30 to 250 °F10 to 210 bar30 bar Per Turn420 bar100 cm3/min @ 1450 Psi (100 bar)Kick Down42 Gal/min50 Nm100 barPilot Operated SequenceExternalNitrileScrew145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3HZV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing3000Mobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 400145 to 3000435 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42371450Pilot Operated SequenceExternalFluorocarbonScrew145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3PTN
Quote Required
TBD
Nitrilen/a-3042Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25060000.55Screw-in CartridgePressure Sensing6000Mobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 250145 to 6000800 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42372900Pilot Operated SequenceExternalNitrileTamper Resistant145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN
B04C3PTV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing6000Mobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 400145 to 6000800 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42372900Pilot Operated SequenceExternalFluorocarbonTamper Resistant145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN
B04C3PWN
Quote Required
TBD
Nitrilen/a-3042Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25060000.55Screw-in CartridgePressure Sensing6000Mobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 250145 to 6000800 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42372900Pilot Operated SequenceExternalNitrileKnob145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN
B04C3PWV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing6000Mobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 400145 to 6000800 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42372900Pilot Operated SequenceExternalFluorocarbonKnob145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN
B04C3PZN
Quote Required
TBD
Nitrilen/a-30 °F160 L/minHydraulic Cartridge Systems DivisionC10-3SMineral-based Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)250 °F420 bar0.27 kgScrew-in CartridgePressure Sensing420 barMobile Hydraulic Systems Division EuropeAutomaticScrew420 bar-30 to 250 °F10 to 420 bar800 psi Per Turn420 bar100 cm3/min @ 1450 Psi (100 bar)Kick Down160 L/min50 Nm2900 psiPilot Operated SequenceExternalNitrileScrew145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN
B04C3PZV
Quote Required
TBD
Fluorocarbonn/a-1542Hydraulic Valve Systems DivisionC10-3SSynthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40060000.55Screw-in CartridgePressure Sensing6000Mobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 400145 to 6000800 psi Per Turn6000100 cm3/min @ 1450 Psi (100 bar)Kick Down42372900Pilot Operated SequenceExternalFluorocarbonScrew145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN