• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Mechanism
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Pressure Control Range
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Pilot Operated Relief Valves

Picture for category Pilot Operated Relief Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s pilot operated relief valves provide a stable design with low pressure drop meant for continuous duty applications while operating with less hydraulic noise. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 400 lpm (106 gpm) in a reliable and compact design. Parker’s pilot operated relief valves are ideal for limiting system pressure or in standard relief valve applications within mobile and industrial equipment such as agricultural, aerial, refuse, industrial power unit systems, mining equipment, and other heavy duty fluid power pressure control circuits.

Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Low leak ball and poppet designs
• Compact design
• Internal screens
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• System pressure limiter
• Port/cross-port relief
• Swing relief
• Motor braking

Additional Technical Insight:
This family of valves is best suited for continuous duty systems where the valve is asked to operate beyond any intermittent use.  They can be used to maintain system pressure for long periods of time.  Additionally, where systems may have large rates of change in flow, the pilot operated valves can accommodate these changes without excessive pressure rise or sometimes called pressure override.  Due to the flow opening areas through the valve, these spool type valves will operate more quietly than a conventional direct acting valve. One must also consider the leakage component as the spool is, by design, going to pass a small leakage flow, whereas a direct acting valve does not pass significant flow until the cracking pressure is reached.  Spool type relief valves should not be used in load holding application.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialMinimum Operating TemperatureMaximum Operating PressureDivisionDivisionMaximum Kinematic ViscosityFlow RateMaximum Flow RateWeightConfigurationActuation TypeOperation TypeAdjustment MechanismFunctionMaximum Tank PressureCavity SizeMaximum Inlet Pressure RatingFor Fluid TypeValve MaterialFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureMounting TypeStandard Setting PressureMaximum Pressure SettingInstallation TorquePressure Control RangePressure Control SensitivityLeak RateReseat PressureSeal MaterialAdjustment MechanismMaximum Inlet Pressure RatingPressure Control RangeFlow Rate
RAH161S20
Quote Required
$0.01
EANitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80800.75Pressure ReliefPressure SensingAutomaticScrewPilot Operated5000C16-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve10002000121-125200-2000539 per turn5 per @ 100 psi (6.8 bar) setting90% of pressure settingNitrileScrew5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR80 GAL/MIN, 302.8 L/MIN
RAH161S20V
Quote Required
TBD
Fluorocarbonn/a-155000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80800.75Pressure ReliefPressure SensingAutomaticScrewPilot Operated5000C16-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve10002000121-125200-2000539 per turn5 per @ 100 psi (6.8 bar) setting90% of pressure settingFluorocarbonScrew5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR80 GAL/MIN, 302.8 L/MIN
RAH161S30
5 In Stock
139 In Stock
$129.38
EANitrilen/a-34 °C5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.75 lbPressure ReliefPressure SensingAutomaticScrewPilot Operated350 barC16-2380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °CScrew in cartridge valve103.5 bar3000 psi121-125 lb-ft20.7-210 bar859 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingNitrileScrew5500 PSI, 380 BAR300-3000 PSI, 20.7-210 BAR80 GAL/MIN, 302.8 L/MIN
RAH161S50
13 In Stock
68 In Stock
$129.38
EANitrilen/a-30 °F5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.34 kgPressure ReliefPressure SensingAutomaticScrewPilot Operated5000 psiC16-25500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve2500 psi5000 psi164-170 Nm34.5-350 bar1910 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingNitrileScrew5500 PSI, 380 BAR500-5000 PSI, 34.5-350 BAR80 GAL/MIN, 302.8 L/MIN
RAH161S50V
Quote Required
TBD
Fluorocarbonn/a-15 °F350 barHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80 Gal/min302.8 L/min0.75 lbPressure ReliefPressure SensingAutomaticScrewPilot Operated5000 psiC16-25500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400 °F+204 °CScrew in cartridge valve2500 psi350 bar121-125 lb-ft500-5000 psi1910 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingFluorocarbonScrew5500 PSI, 380 BAR500-5000 PSI, 34.5-350 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T10
Quote Required
$143.63
EANitrilen/a-30 °F5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80 Gal/min80 Gal/min0.34 kgPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated5000 psiC16-25500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve500 psi69 bar164-170 Nm100-1000 psi19.6 per turn bar5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingNitrileTamper Resistant5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T10V
Quote Required
TBD
Fluorocarbonn/a-26 °C5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.34 kgPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated350 barC16-25500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-26 to +204 °C+204 °CScrew in cartridge valve500 psi69 bar121-125 lb-ft6.9-69 bar285 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingFluorocarbonTamper Resistant5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T20
Quote Required
TBD
Nitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80800.75Pressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated5000C16-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve10002000121-125200-2000539 per turn5 per @ 100 psi (6.8 bar) setting90% of pressure settingNitrileTamper Resistant5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T20V
Quote Required
TBD
Fluorocarbonn/a-155000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)80800.75Pressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated5000C16-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve10002000121-125200-2000539 per turn5 per @ 100 psi (6.8 bar) setting90% of pressure settingFluorocarbonTamper Resistant5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T30
Quote Required
TBD
Nitrilen/a-34 °C5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.75 lbPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated5000 psiC16-2380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °CScrew in cartridge valve103.5 bar210 bar121-125 lb-ft300-3000 psi859 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingNitrileTamper Resistant5500 PSI, 380 BAR300-3000 PSI, 20.7-210 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T30V
Quote Required
TBD
Fluorocarbonn/a-26 °C5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.34 kgPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated350 barC16-2380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400 °F+400 °FScrew in cartridge valve1500 psi3000 psi121-125 lb-ft20.7-210 bar58.9 per turn bar5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingFluorocarbonTamper Resistant5500 PSI, 380 BAR300-3000 PSI, 20.7-210 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T50
Quote Required
$143.63
EANitrilen/a-30 °F350 barHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.75 lbPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated350 barC16-25500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve172.4 bar350 bar164-170 Nm500-5000 psi131.7 per turn bar5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingNitrileTamper Resistant5500 PSI, 380 BAR500-5000 PSI, 34.5-350 BAR80 GAL/MIN, 302.8 L/MIN
RAH161T50V
Quote Required
TBD
Fluorocarbonn/a-26 °C5000 psiHydraulic Cartridge Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)302.8 L/min302.8 L/min0.34 kgPressure ReliefPressure SensingAutomaticTamper ResistantPilot Operated350 barC16-2380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-26 to +204 °C+204 °CScrew in cartridge valve2500 psi5000 psi164-170 Nm500-5000 psi1910 per turn psi5 per @ 100 psi (6.8 bar) setting cm3/min90% of pressure settingFluorocarbonTamper Resistant5500 PSI, 380 BAR500-5000 PSI, 34.5-350 BAR80 GAL/MIN, 302.8 L/MIN
RAH201F10
Quote Required
TBD
Nitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve500100098100-1000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingNitrileFixed5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR100 GAL/MIN, 379 L/MIN
RAH201F10V
Quote Required
TBD
Fluorocarbonn/a-155000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve500100098100-1000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingFluorocarbonFixed5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR100 GAL/MIN, 379 L/MIN
RAH201F20
Quote Required
TBD
Nitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve1000200098200-2000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingNitrileFixed5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR100 GAL/MIN, 379 L/MIN
RAH201F20V
Quote Required
TBD
Fluorocarbonn/a-155000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve1000200098200-2000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingFluorocarbonFixed5500 PSI, 380 BAR200-2000 PSI, 13.8-138 BAR100 GAL/MIN, 379 L/MIN
RAH201F30
Quote Required
TBD
Nitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve1500300098300-3000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingNitrileFixed5500 PSI, 380 BAR300-3000 PSI, 20.7-210 BAR100 GAL/MIN, 379 L/MIN
RAH201F30V
Quote Required
TBD
Fluorocarbonn/a-155000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve1500300098300-3000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingFluorocarbonFixed5500 PSI, 380 BAR300-3000 PSI, 20.7-210 BAR100 GAL/MIN, 379 L/MIN
RAH201F50
Quote Required
TBD
Nitrilen/a-305000Hydraulic Valve Systems DivisionHydraulic Systems Division45-2000 SSU (6 to 420 cSt)1001002Pressure ReliefPressure SensingAutomaticFixedPilot Operated5000C20-25500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve2500500098500-5000n/a5 per @ 100 psi (6.8 bar) setting80% of pressure settingNitrileFixed5500 PSI, 380 BAR500-5000 PSI, 34.5-350 BAR100 GAL/MIN, 379 L/MIN