- Availability & Price
- Search SKU
Filter by attributes
- Adjustment Mechanism
- Flow Rate
- Maximum Inlet Pressure Rating
- Pressure Control Range
- Seal Material
Filter by manufacturer
Pilot Operated Relief Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s pilot operated relief valves provide a stable design with low pressure drop meant for continuous duty applications while operating with less hydraulic noise. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 400 lpm (106 gpm) in a reliable and compact design. Parker’s pilot operated relief valves are ideal for limiting system pressure or in standard relief valve applications within mobile and industrial equipment such as agricultural, aerial, refuse, industrial power unit systems, mining equipment, and other heavy duty fluid power pressure control circuits.
Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High pressure and flow capacity
• Low leak ball and poppet designs
• Compact design
• Internal screens
• Hardened, precision ground parts for durability
• All external parts zinc plated
Applications:
• System pressure limiter
• Port/cross-port relief
• Swing relief
• Motor braking
Additional Technical Insight:
This family of valves is best suited for continuous duty systems where the valve is asked to operate beyond any intermittent use. They can be used to maintain system pressure for long periods of time. Additionally, where systems may have large rates of change in flow, the pilot operated valves can accommodate these changes without excessive pressure rise or sometimes called pressure override. Due to the flow opening areas through the valve, these spool type valves will operate more quietly than a conventional direct acting valve. One must also consider the leakage component as the spool is, by design, going to pass a small leakage flow, whereas a direct acting valve does not pass significant flow until the cracking pressure is reached. Spool type relief valves should not be used in load holding application.
Read More...Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High pressure and flow capacity
• Low leak ball and poppet designs
• Compact design
• Internal screens
• Hardened, precision ground parts for durability
• All external parts zinc plated
Applications:
• System pressure limiter
• Port/cross-port relief
• Swing relief
• Motor braking
Additional Technical Insight:
This family of valves is best suited for continuous duty systems where the valve is asked to operate beyond any intermittent use. They can be used to maintain system pressure for long periods of time. Additionally, where systems may have large rates of change in flow, the pilot operated valves can accommodate these changes without excessive pressure rise or sometimes called pressure override. Due to the flow opening areas through the valve, these spool type valves will operate more quietly than a conventional direct acting valve. One must also consider the leakage component as the spool is, by design, going to pass a small leakage flow, whereas a direct acting valve does not pass significant flow until the cracking pressure is reached. Spool type relief valves should not be used in load holding application.
| Action | Part No. | Availability | Partner Available | Price | UOM | Seal Material | Body Material | Division | Division | Maximum Kinematic Viscosity | Flow Rate | Maximum Flow Rate | Minimum Operating Temperature | Maximum Operating Pressure | Configuration | Actuation Type | Operation Type | Adjustment Mechanism | Function | Maximum Tank Pressure | Maximum Pressure Setting | Cavity Size | Maximum Inlet Pressure Rating | Maximum Operating Temperature | For Fluid Type | Valve Material | Operating Temperature | Filter Efficiency Rating | Mounting Type | Installation Torque | Weight | Standard Setting Pressure | Pressure Control Range | Pressure Control Sensitivity | Reseat Pressure | Leak Rate | Seal Material | Adjustment Mechanism | Maximum Inlet Pressure Rating | Pressure Control Range | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAH121T50 | Quote Required | TBD | Nitrile | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 50 Gal/min | 50 Gal/min | -34 °C | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Tamper Resistant | Pilot Operated | 5000 psi | 5000 psi | C12-2 | 5500 psi | +250 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 92-96 lb-ft | 0.48 lb | 172.4 bar | 34.5-350 bar | 118 per turn bar | 80% of pressure setting | 82 @ 75% Crack Pressure cm3/min | Nitrile | Tamper Resistant | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 50 GAL/MIN, 189.5 L/MIN | |||
| RAH121T50V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 50 Gal/min | 50 Gal/min | -26 °C | 5000 psi | Pressure Relief | Pressure Sensing | Automatic | Tamper Resistant | Pilot Operated | 350 bar | 5000 psi | C12-2 | 5500 psi | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 92-96 lb-ft | 0.48 lb | 172.4 bar | 500-5000 psi | 118 per turn bar | 80% of pressure setting | 82 @ 75% Crack Pressure cm3/min | Fluorocarbon | Tamper Resistant | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 50 GAL/MIN, 189.5 L/MIN | |||
| RAH161F10 | Quote Required | TBD | Nitrile | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -30 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 1000 | C16-2 | 5500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 500 | 100-1000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Nitrile | Fixed | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F10V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -15 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 1000 | C16-2 | 5500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 500 | 100-1000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Fluorocarbon | Fixed | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F20 | Quote Required | TBD | Nitrile | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -30 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 2000 | C16-2 | 5500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1000 | 200-2000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Nitrile | Fixed | 5500 PSI, 380 BAR | 200-2000 PSI, 13.8-138 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F20V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -15 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 2000 | C16-2 | 5500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1000 | 200-2000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Fluorocarbon | Fixed | 5500 PSI, 380 BAR | 200-2000 PSI, 13.8-138 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F30 | Quote Required | TBD | Nitrile | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -30 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 3000 | C16-2 | 5500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1500 | 300-3000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Nitrile | Fixed | 5500 PSI, 380 BAR | 300-3000 PSI, 20.7-210 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F30V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -15 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 3000 | C16-2 | 5500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1500 | 300-3000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Fluorocarbon | Fixed | 5500 PSI, 380 BAR | 300-3000 PSI, 20.7-210 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F50 | Quote Required | TBD | Nitrile | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -30 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 5000 | C16-2 | 5500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 2500 | 500-5000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Nitrile | Fixed | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161F50V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -15 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Fixed | Pilot Operated | 5000 | 5000 | C16-2 | 5500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 2500 | 500-5000 | n/a | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Fluorocarbon | Fixed | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K10 | Quote Required | TBD | Nitrile | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 302.8 L/min | -30 °F | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 psi | 69 bar | C16-2 | 380 bar | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 164-170 Nm | 0.75 lb | 500 psi | 100-1000 psi | 285 per turn psi | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Nitrile | Knob | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K10V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 302.8 L/min | -26 °C | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 350 bar | 1000 psi | C16-2 | 5500 psi | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 164-170 Nm | 0.34 kg | 500 psi | 100-1000 psi | 285 per turn psi | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Fluorocarbon | Knob | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K20 | Quote Required | TBD | Nitrile | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -30 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 | 2000 | C16-2 | 5500 | +250 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1000 | 200-2000 | 539 per turn | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Nitrile | Knob | 5500 PSI, 380 BAR | 200-2000 PSI, 13.8-138 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K20V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Valve Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 | 80 | -15 | 5000 | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 | 2000 | C16-2 | 5500 | +400 | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 | 0.75 | 1000 | 200-2000 | 539 per turn | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting | Fluorocarbon | Knob | 5500 PSI, 380 BAR | 200-2000 PSI, 13.8-138 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K30 | Quote Required | TBD | Nitrile | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 Gal/min | 80 Gal/min | -34 °C | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 psi | 3000 psi | C16-2 | 380 bar | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.34 kg | 103.5 bar | 20.7-210 bar | 58.9 per turn bar | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Nitrile | Knob | 5500 PSI, 380 BAR | 300-3000 PSI, 20.7-210 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K30V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 302.8 L/min | -26 °C | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 psi | 3000 psi | C16-2 | 380 bar | +204 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.75 lb | 103.5 bar | 20.7-210 bar | 58.9 per turn bar | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Fluorocarbon | Knob | 5500 PSI, 380 BAR | 300-3000 PSI, 20.7-210 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K50 | Quote Required | TBD | Nitrile | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 80 Gal/min | -34 °C | 5000 psi | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 5000 psi | 350 bar | C16-2 | 380 bar | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.75 lb | 172.4 bar | 500-5000 psi | 131.7 per turn bar | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Nitrile | Knob | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161K50V | Quote Required | TBD | Fluorocarbon | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 302.8 L/min | -15 °F | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Knob | Pilot Operated | 350 bar | 350 bar | C16-2 | 380 bar | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.34 kg | 2500 psi | 34.5-350 bar | 131.7 per turn bar | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Fluorocarbon | Knob | 5500 PSI, 380 BAR | 500-5000 PSI, 34.5-350 BAR | 80 GAL/MIN, 302.8 L/MIN | |||
| RAH161S10 | Quote Required | 33 In Stock | $129.38 | EA | Nitrile | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 302.8 L/min | 80 Gal/min | -34 °C | 350 bar | Pressure Relief | Pressure Sensing | Automatic | Screw | Pilot Operated | 5000 psi | 1000 psi | C16-2 | 5500 psi | +121 °C | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.34 kg | 500 psi | 100-1000 psi | 285 per turn psi | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Nitrile | Screw | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN | |
| RAH161S10V | Quote Required | $140.63 | EA | Fluorocarbon | n/a | Hydraulic Cartridge Systems Division | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | 80 Gal/min | 302.8 L/min | -26 °C | 5000 psi | Pressure Relief | Pressure Sensing | Automatic | Screw | Pilot Operated | 350 bar | 1000 psi | C16-2 | 5500 psi | +400 °F | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | Screw in cartridge valve | 121-125 lb-ft | 0.34 kg | 34.5 bar | 100-1000 psi | 285 per turn psi | 90% of pressure setting | 5 per @ 100 psi (6.8 bar) setting cm3/min | Fluorocarbon | Screw | 5500 PSI, 380 BAR | 100-1000 PSI, 6.9-69 BAR | 80 GAL/MIN, 302.8 L/MIN |