- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Pilot Operated Directional Control Valve - D31DW, D31VW Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D31 directional control valves are suitable for manifold or subplate mounting. These valves conform to NFPA’s D05, CETOP 5 and D05HE, CETOP 5H mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Mounting bolts below center line of spool minimizes spool binding
• Five chamber style eliminates pressure spikes in tubes, increasing valve life
• High pressure & flow ratings provide increased performance options in a compact valve
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Mounting bolts below center line of spool minimizes spool binding
• Five chamber style eliminates pressure spikes in tubes, increasing valve life
• High pressure & flow ratings provide increased performance options in a compact valve
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Pressure | Valve Type | Mounting Type | Maximum Operating Temperature | Coil Specifications Met | Spool Code | Connection Type | Pilot Inlet / Drain Locations | Actuation Type | Maximum Flow Rate | Minimum Operating Temperature | Options | Seal Material | Additional Options | Weight | Power Supply Voltage | Body Material | Division | Solenoid Option | Spool Position | Size | Maximum Flow Rate | Maximum Operating Pressure | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D31VW081C4NYWF | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Low Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5704 psi/ 345 bar | Subplate | ||
| D31VW081C4NYWF. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Low Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5704 psi/ 345 bar | Subplate | ||
| D31VW082C4NJW | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | Omit - High Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5705 psi/ 345 bar | Subplate | ||
| D31VW082C4NJW. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | Omit - High Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5705 psi/ 345 bar | Subplate | ||
| D31VW082C4NYC | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | Leadwire Conduit Box | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Omit - High Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5706 psi/ 345 bar | Subplate | ||
| D31VW082C4NYC. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | Leadwire Conduit Box | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Omit - High Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5706 psi/ 345 bar | Subplate | ||
| D31VW082C4NYW3A | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Pilot Choke Meter-out | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | High Watt (standard) | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5707 psi/ 345 bar | Subplate | ||
| D31VW082C4NYW3A. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Pilot Choke Meter-out | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | High Watt (standard) | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5707 psi/ 345 bar | Subplate | ||
| D31VW082C4NYWF | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Low Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5708 psi/ 345 bar | Subplate | ||
| D31VW082C4NYWF. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | Low Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5708 psi/ 345 bar | Subplate | ||
| D31VW082C4VJWL | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Fluorocarbon | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | 10 Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5709 psi/ 345 bar | Subplate | ||
| D31VW082C4VJWL. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Fluorocarbon | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | 10 Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5709 psi/ 345 bar | Subplate | ||
| D31VW082C4VJWL4 | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | CSA | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Fluorocarbon | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | 10 Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5710 psi/ 345 bar | Subplate | ||
| D31VW082C4VJWL4. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | CSA | 4-Way | DIN w/o Plug | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Omit | Fluorocarbon | Consult catalog for additional features. | 12 | 24 | Gray Iron | Hydraulic Valve Systems Division | 10 Watt | Double Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5710 psi/ 345 bar | Subplate | ||
| D31VW082E4NYC3A | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | Leadwire Conduit Box | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Pilot Choke Meter-out | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | High Watt (standard) | Single Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5711 psi/ 345 bar | Subplate | ||
| D31VW082E4NYC3A. | Quote Required | TBD | 5000 | Pilot Operated Directional Control Valve | Subplate | 140 | Omit | 4-Way | Leadwire Conduit Box | Internal Pilot / Internal Drain | Hydraulic Pressure | 30 | -4 | Pilot Choke Meter-out | Nitrile | Consult catalog for additional features. | 12 | 120/60 - 110/50 VAC | Gray Iron | Hydraulic Valve Systems Division | High Watt (standard) | Single Solenoid | NFPA D05H, CETOP 5, D03 Pilot, NFPA Port | 30 gal/min | 5711 psi/ 345 bar | Subplate |