• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Mounting Type
  • Size
More Filters...
Filter by manufacturer
Manufacturers

Pilot Operated Directional Control Valve - D31DW, D31VW Series

Picture for category Pilot Operated Directional Control Valve - D31DW, D31VW Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D31 directional control valves are suitable for manifold or subplate mounting. These valves conform to NFPA’s D05, CETOP 5 and D05HE, CETOP 5H mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Mounting bolts below center line of spool minimizes spool binding
• Five chamber style eliminates pressure spikes in tubes, increasing valve life
• High pressure & flow ratings provide increased performance options in a compact valve

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Operating PressureValve TypeMounting TypeMaximum Operating TemperatureCoil Specifications MetSpool CodeConnection TypePilot Inlet / Drain LocationsActuation TypeMaximum Flow RateMinimum Operating TemperatureOptionsSeal MaterialAdditional OptionsWeightPower Supply VoltageBody MaterialDivisionSolenoid OptionSpool PositionSizeMaximum Flow RateMaximum Operating PressureMounting Type
D31VW081C4NYWF
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionLow WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5704 psi/ 345 barSubplate
D31VW081C4NYWF.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionLow WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5704 psi/ 345 barSubplate
D31VW082C4NJW
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.1224Gray IronHydraulic Valve Systems DivisionOmit - High WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5705 psi/ 345 barSubplate
D31VW082C4NJW.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.1224Gray IronHydraulic Valve Systems DivisionOmit - High WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5705 psi/ 345 barSubplate
D31VW082C4NYC
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayLeadwire Conduit BoxInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionOmit - High WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5706 psi/ 345 barSubplate
D31VW082C4NYC.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayLeadwire Conduit BoxInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionOmit - High WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5706 psi/ 345 barSubplate
D31VW082C4NYW3A
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4Pilot Choke Meter-outNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionHigh Watt (standard)Double SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5707 psi/ 345 barSubplate
D31VW082C4NYW3A.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4Pilot Choke Meter-outNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionHigh Watt (standard)Double SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5707 psi/ 345 barSubplate
D31VW082C4NYWF
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionLow WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5708 psi/ 345 barSubplate
D31VW082C4NYWF.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionLow WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5708 psi/ 345 barSubplate
D31VW082C4VJWL
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitFluorocarbonConsult catalog for additional features.1224Gray IronHydraulic Valve Systems Division10 WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5709 psi/ 345 barSubplate
D31VW082C4VJWL.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitFluorocarbonConsult catalog for additional features.1224Gray IronHydraulic Valve Systems Division10 WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5709 psi/ 345 barSubplate
D31VW082C4VJWL4
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140CSA4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitFluorocarbonConsult catalog for additional features.1224Gray IronHydraulic Valve Systems Division10 WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5710 psi/ 345 barSubplate
D31VW082C4VJWL4.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140CSA4-WayDIN w/o PlugInternal Pilot / Internal DrainHydraulic Pressure30-4OmitFluorocarbonConsult catalog for additional features.1224Gray IronHydraulic Valve Systems Division10 WattDouble SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5710 psi/ 345 barSubplate
D31VW082E4NYC3A
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayLeadwire Conduit BoxInternal Pilot / Internal DrainHydraulic Pressure30-4Pilot Choke Meter-outNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionHigh Watt (standard)Single SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5711 psi/ 345 barSubplate
D31VW082E4NYC3A.
Quote Required
TBD
5000Pilot Operated Directional Control ValveSubplate140Omit4-WayLeadwire Conduit BoxInternal Pilot / Internal DrainHydraulic Pressure30-4Pilot Choke Meter-outNitrileConsult catalog for additional features.12120/60 - 110/50 VACGray IronHydraulic Valve Systems DivisionHigh Watt (standard)Single SolenoidNFPA D05H, CETOP 5, D03 Pilot, NFPA Port30 gal/min5711 psi/ 345 barSubplate