Products specifications
Attribute nameAttribute value
Seal MaterialFluorocarbonBody Materialn/a
Maximum Operating Pressure5000 psiDivisionHydraulic Cartridge Systems Division
DivisionHydraulic Systems DivisionMaximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)
Minimum Operating Temperature-26 °CWeight2 lb
Maximum Flow Rate40 Gal/minActuation TypePressure Sensing
Operation TypeAutomaticAdjustment MechanismScrew
FunctionPilot OperatedMaximum Tank Pressure350 bar
Cavity SizeC16-3Maximum Inlet Pressure Rating380 bar
Installation Torque99 NmMaximum Operating Temperature+204 °C
Flow Rate150 L/minFor Fluid TypeMineral-based or synthetic hydraulic fluids
Operating Temperature-15 to +400 °FFilter Efficiency RatingISO 4406 18/16/13, SAE Class 4
Mounting TypeScrew in cartridge valveValve MaterialAll parts steel. All operating parts hardened steel.
Maximum Drain Flow Rate0.94 L/minMaximum Pressure Setting69 bar
Standard Setting Pressure34.5 barConfigurationPressure Reducing
Pressure Control Range100-1000 psiPressure Control Sensitivity334 per turn psi
Seal MaterialFluorocarbonAdjustment MechanismScrew
Flow Rate40 GAL/MIN, 150 L/MINPressure Control Range100-1000 PSI, 6.9-69 BAR