Parker PR103K12 - Direct Acting Pressure Reducing Relieving Valves

Parker’s direct acting reducing & relieving valves are used in intermittent duty applications where specific functions require reduced and regulated pressure. Capable of flows up to 56 lpm (13 gpm) and pressures up to 420 bar (6000 psi).
Availability:
Partner Available:Quote Required
Brand Parker
Part No. PR103K12
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Maximum Pressure Differential1000 psiMaximum Operating Temperature+200 °F
For Fluid TypeMineral-based or synthetic hydraulic fluidsMaximum Flow Rate56 L/min
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Seal MaterialD-Ring (Standard)
Weight0.23 kgMinimum Operating Temperature-37 °C
Operation TypeAutomaticCavity SizeC10-3
ConfigurationPressure Reducing/RelievingMaximum Operating Pressure3000 psi
Pressure Control Sensitivity11.4 per turn barValve MaterialAll parts steel. All operating parts hardened steel.
Adjustment MechanismKnobStandard Setting Pressure41.4 bar
Filter Efficiency RatingISO 4406 18/16/13, SAE Class 4Installation Torque37-41 lb-ft
Maximum Drain Flow Rate0.03 Gal/minFlow Rate56 L/min
Operating Temperature-37 to +93 °CMaximum Pressure Setting1200 psi
Maximum Tank Pressure124 barBody Materialn/a
FunctionDirect ActingMounting TypeScrew in cartridge valve
Actuation TypePressure SensingDivisionHydraulic Systems Division
Maximum Inlet Pressure Rating210 barPressure Control Range39.3-83 bar
Seal MaterialD-Ring (Standard)Flow Rate15 GAL/MIN, 56 L/MIN
Adjustment MechanismKnobMaximum Inlet Pressure Rating3000 PSI, 210 BAR
Pressure Control Range570-1200 PSI, 39.3-83 BAR