Parker AC025ENFI - OIL-X 'Point Of Use' Oil Vapour Reduction Filters

Activated carbon filters for the reduction of oil vapour and hydrocarbon odours, providing a maximum remaining oil content of <0.003mg/m³ (<0.003ppm) @ 21°C (70°F).
Availability:
Partner Available: Quote Required
Brand Parker
Part No. AC025ENFI
TBD
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute name Attribute value
Brand Parker Technology Filtration
Division Gas Separation and Filtration Division EMEA Industry Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental
Application Compressed Air and Nitrogen Gas Applications Division Gas Separation and Filtration Division EMEA
Depth 4.5 inch Micron Rating down to 0.01 MICRON
Product Type Compressed Air Filter Materials of Construction Die Cast Aluminium
Operating Pressure 15 to 232 psig Product Series OIL-X Grades ACS and AC
Operating Temperature 35 to 86 °F Filter Type Oil Vapour Reduction
Specifications Met Fully tested - In accordance with ISO8573-2, 4 and 5<br/><br/>Filtration performance independently validated - by Lloyds Register.<br/><br/>PED 2014/68/EU Fluid Group II Residual Oil Content Aerosols:<br/>0.01 mg/m³ / 0.01 ppm(w) <br/>@ 21°C (70°F)<br/><br/>Vapour:<br/>0.003 mg/m³ / 0.003 ppm(w) <br/>@ 21°C (70°F)
Pressure Differential 11 psi Initial Dry, 100% Flow Width 5.1 inch
Height 554.0 mm Weight 7.6 lb
Compatible Element P025AA and 025EAC<br/>Requires Both Element Change Interval P025AA:<br/> 12 Months<br/><br/>025EAC:<br/> When oil vapour is detected
Port Size 1 inch Connection Type NPT
Drain Automatic Float Filter Stages Double Stage
Maximum Flow Rate 231 m³/h @ 7 barg (136 cfm @ 102 psig)