• Availability & Price
  • Search SKU
Filter by attributes
  • Body Material
  • Coil Type
  • Maximum Pressure Differential (psi)
  • Orifice 1 Size (inch)
  • Power (Watts)
  • Seal Material
  • Voltage (V)
More Filters...
Filter by manufacturer
Manufacturers

Parker 2-Way Normally Open, 1/2" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Open, 1/2" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Open 1/2" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort SizePort TypeDivisionMediaFunctionValve TypeInput VoltageOrifice 2 SizeNumber of PortsFlow Coefficient 2Minimum Fluid TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialBody MaterialSeal MaterialActuation TypeFlow Coefficient 1Maximum Fluid TemperatureProduct SeriesPower ConsumptionCoil TypeOrifice 1 SizeCoil Specifications MetVoltage (V)Maximum Pressure Differential (psi)Seal MaterialCoil TypeOrifice 1 Size (inch)Power (Watts)Body Material
72228RN4UV00N0H322Q3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way220/50 to 240/60n/a2n/a0125 psi (AC)0Stainless Steel 316FKMDirect Lift41857000 Series22 W (AC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 97/16NEMA 9220/50-240/60125 psi (AC)FKM1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 97/1622 Watt (AC)316 Stainless
73228BN4UN00N0C111C1
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way12.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/16NEMA 4X12 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/1610 Watt (DC)BRASS
73228BN4UN00N0C111C2
Quote Required
TBD
1/2 inchNPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way24.0 VDCn/a2n/a0 °F150 psi (DC)5 psiBrassNBRMechanical4 Cv185 °F7000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/16 inchNEMA 4X24 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/1610 Watt (DC)BRASS
73228BN4UN00N0C111P3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way110/50-120/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/16NEMA 4X110/50-120/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/1610 Watt (AC)BRASS
73228BN4UN00N0C111Q3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way220/50 to 240/60n/a2n/a0150 psi (AC)5BrassNBRMechanical41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/16NEMA 4X220/50-240/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X7/1610 Watt (AC)BRASS
73228BN4UN00N0C222C1
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way12.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/16NEMA 4X12 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/1610 Watt (DC)BRASS
73228BN4UN00N0C222C2
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way24.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/16NEMA 4X24 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/1610 Watt (DC)BRASS
73228BN4UN00N0C222P3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way110/50-120/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/16NEMA 4X110/50-120/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/1610 Watt (AC)BRASS
73228BN4UN00N0C222Q3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way220/50 to 240/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/16NEMA 4X220/50-240/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X7/1610 Watt (AC)BRASS
73228BN4UN00N0D100C1
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way12.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)DIN Form A, Class F7/16Class F12 VDC150 psi (DC)NBRDIN Form A, Class F7/1610 Watt (DC)BRASS
73228BN4UN00N0D100C2
Quote Required
TBD
1/2 inchNPTFluid Control DivisionLiquids and GasesNormally Open (NO)2-Way24.0 VDCn/a2n/a0 °F150 psi (DC)5 psiBrassNBRManual4 Cv185 °F7000 Series10 W (DC)DIN Form A, Class F7/16 inchClass F24 VDC150 psi (DC)NBRDIN Form A, Class F7/1610 Watt (DC)BRASS
73228BN4UN00N0D100P3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way110/50-120/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)DIN Form A, Class F7/16Class F110/50-120/60150 psi (AC)NBRDIN Form A, Class F7/1610 Watt (AC)BRASS
73228BN4UN00N0D100Q3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way220/50 to 240/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)DIN Form A, Class F7/16Class F220/50-240/60150 psi (AC)NBRDIN Form A, Class F7/1610 Watt (AC)BRASS
73228BN4UN00N0D200C1
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way12.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)DIN Form A, Class H7/16Class H12 VDC150 psi (DC)NBRDIN Form A, Class H7/1610 Watt (DC)BRASS
73228BN4UN00N0D200P3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way110/50-120/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)DIN Form A, Class H7/16Class H110/50-120/60150 psi (AC)NBRDIN Form A, Class H7/1610 Watt (AC)BRASS
73228BN4UN00N0H111C1
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way12.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/16NEMA 912 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/1610 Watt (DC)BRASS
73228BN4UN00N0H111C2
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way24.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/16NEMA 924 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/1610 Watt (DC)BRASS
73228BN4UN00N0H111P3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way110/50-120/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/16NEMA 9110/50-120/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/1610 Watt (AC)BRASS
73228BN4UN00N0H111Q3
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way220/50 to 240/60n/a2n/a0150 psi (AC)5BrassNBRManual41857000 Series10 W (AC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/16NEMA 9220/50-240/60150 psi (AC)NBR1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 97/1610 Watt (AC)BRASS
73228BN4UN00N0H222C2
Quote Required
TBD
1/2NPTFluid Control DivisionGeneral Purpose for AirNormally Open (NO)2-Way24.0n/a2n/a0150 psi (DC)5BrassNBRManual41857000 Series10 W (DC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 97/16NEMA 924 VDC150 psi (DC)NBR1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 97/1610 Watt (DC)BRASS