• Availability & Price
  • Search SKU
Filter by attributes
  • Body Material
  • Coil Type
  • Maximum Pressure Differential (psi)
  • Orifice 1 Size (inch)
  • Power (Watts)
  • Seal Material
  • Voltage (V)
More Filters...
Filter by manufacturer
Manufacturers

Parker 2-Way Normally Open, 1/2" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Open, 1/2" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Open 1/2" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMMediaFunctionCoil TypePort SizePort TypeBody MaterialInput VoltageSeal MaterialActuation TypePower ConsumptionDivisionMaximum Fluid TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialValve TypeOrifice 1 SizeOrifice 2 SizeProduct SeriesNumber of PortsFlow Coefficient 1Flow Coefficient 2Coil Specifications MetMinimum Fluid TemperatureCoil TypeBody MaterialSeal MaterialVoltage (V)Power (Watts)Orifice 1 Size (inch)Maximum Pressure Differential (psi)
08F23O2140A3FPH75
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class F1/2NPTBrass12.0NBRHung Diaphragm11.5 W (DC)Fluid Control Division150125 psi (DC)02-Way5/8n/aGold Ring Series24n/aClass F0DIN Form A, Class FBRASSNBR12 VDC11.5 Watt (DC)5/8125 psi (DC)
08F23O2140ACFPH01
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class F1/2NPTBrass24/60NBRHung Diaphragm11 W (AC)Fluid Control Division150150 psi (AC)02-Way5/8n/aGold Ring Series24n/aClass F0DIN Form A, Class FBRASSNBR24/6011 Watt (AC)5/8150 psi (AC)
08F23O2140ACFPH15
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class F1/2NPTBrass220/50 to 240/60NBRHung Diaphragm11 W (AC)Fluid Control Division150150 psi (AC)02-Way5/8n/aGold Ring Series24n/aClass F0DIN Form A, Class FBRASSNBR220/50-240/6011 Watt (AC)5/8150 psi (AC)
72228BN4UV00N0C322C1
Quote Required
TBD
Liquids and GasesNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2 inchNPTBrass12.0 VDCFKMDirect Lift22 W (DC)Fluid Control Division185 °F125 psi (DC)0 psi2-Way7/16 inchn/a7000 Series24 Cvn/aNEMA 4X0 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 4XBRASSFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0C322C2
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2NPTBrass24.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 4X01/2" NPT Conduit, 18" Leads, Class H, NEMA 4XBRASSFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0C322P3
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2NPTBrass110/50-120/60FKMDirect Lift22 W (AC)Fluid Control Division185125 psi (AC)02-Way7/16n/a7000 Series24n/aNEMA 4X01/2" NPT Conduit, 18" Leads, Class H, NEMA 4XBRASSFKM110/50-120/6022 Watt (AC)7/16125 psi (AC)
72228BN4UV00N0D300C1
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class H1/2NPTBrass12.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aClass H0DIN Form A, Class HBRASSFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0D300C2
Quote Required
TBD
Liquids and GasesNormally Open (NO)DIN Form A, Class H1/2 inchNPTBrass24.0 VDCFKMDirect Lift22 W (DC)Fluid Control Division185 °F125 psi (DC)0 psi2-Way7/16 inchn/a7000 Series24 Cvn/aClass H0 °FDIN Form A, Class HBRASSFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0H322C1
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTBrass12.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASSFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0H322C2
Quote Required
$0.01
EAGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTBrass24.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASSFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228BN4UV00N0H322P3
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTBrass110/50-120/60FKMDirect Lift22 W (AC)Fluid Control Division185125 psi (AC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASSFKM110/50-120/6022 Watt (AC)7/16125 psi (AC)
72228BN4UV00N0H322Q3
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTBrass220/50 to 240/60FKMDirect Lift22 W (AC)Fluid Control Division185125 psi (AC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASSFKM220/50-240/6022 Watt (AC)7/16125 psi (AC)
72228RN4UV00N0C322C1
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2NPTStainless Steel 31612.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 4X01/2" NPT Conduit, 18" Leads, Class H, NEMA 4X316 StainlessFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0C322C2
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2NPTStainless Steel 31624.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 4X01/2" NPT Conduit, 18" Leads, Class H, NEMA 4X316 StainlessFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0C322P3
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X1/2NPTStainless Steel 316110/50-120/60FKMDirect Lift22 W (AC)Fluid Control Division185125 psi (AC)02-Way7/16n/a7000 Series24n/aNEMA 4X01/2" NPT Conduit, 18" Leads, Class H, NEMA 4X316 StainlessFKM110/50-120/6022 Watt (AC)7/16125 psi (AC)
72228RN4UV00N0D300C1
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class H1/2NPTStainless Steel 31612.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aClass H0DIN Form A, Class H316 StainlessFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0D300C2
Quote Required
TBD
General Purpose for AirNormally Open (NO)DIN Form A, Class H1/2NPTStainless Steel 31624.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aClass H0DIN Form A, Class H316 StainlessFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0H322C1
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTStainless Steel 31612.0FKMDirect Lift22 W (DC)Fluid Control Division185125 psi (DC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9316 StainlessFKM12 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0H322C2
Quote Required
TBD
Liquids and GasesNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2 inchNPTStainless Steel 31624.0 VDCFKMDirect Lift22 W (DC)Fluid Control Division185 °F125 psi (DC)0 psi2-Way7/16 inchn/a7000 Series24 Cvn/aNEMA 70 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9316 StainlessFKM24 VDC22 Watt (DC)7/16125 psi (DC)
72228RN4UV00N0H322P3
Quote Required
TBD
General Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 91/2NPTStainless Steel 316110/50-120/60FKMDirect Lift22 W (AC)Fluid Control Division185125 psi (AC)02-Way7/16n/a7000 Series24n/aNEMA 901/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9316 StainlessFKM110/50-120/6022 Watt (AC)7/16125 psi (AC)