OIL-X Carbon Steel Fabricated Compressed Air Filter (For Pressures Up To 16 bar g)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker domnick hunter OIL-X range of fabricated carbon steel compressed air filters combine an innovative filter housing and filter element design to achieve optimum flow characteristics with minimum pressure drop, resulting in considerable cost savings throughout the entire operating lifetime of the filter element.
The filter housing has been designed for ease of maintenance. A low placed service flange, supported by a pivoting hinge joint, enables element replacement to be undertaken by a single individual. A dished housing bottom provides ample space to drain away liquids efficiently. The patented filter element design provides a secure seal to avoid any possibility of contamination bypassing the element.
Features
• Fabricated from carbon steel
• Standard range up to 16 barg (232 psig)
• Stainless steel models also available
• Designed in accordance with AD-2000
• Easy fit element location for quick and simple maintenance
• Coalescing filter performance tested to the stringent requirements of ISO12500-1 and ISO8573-2
• Dry particulate filter performance tested in accordance with the requirements of ISO8573-4
• Differential pressure gauge can be fitted as optional extra
Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...The filter housing has been designed for ease of maintenance. A low placed service flange, supported by a pivoting hinge joint, enables element replacement to be undertaken by a single individual. A dished housing bottom provides ample space to drain away liquids efficiently. The patented filter element design provides a secure seal to avoid any possibility of contamination bypassing the element.
Features
• Fabricated from carbon steel
• Standard range up to 16 barg (232 psig)
• Stainless steel models also available
• Designed in accordance with AD-2000
• Easy fit element location for quick and simple maintenance
• Coalescing filter performance tested to the stringent requirements of ISO12500-1 and ISO8573-2
• Dry particulate filter performance tested in accordance with the requirements of ISO8573-4
• Differential pressure gauge can be fitted as optional extra
Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Brand | Division | Maximum Operating Temperature | Minimum Operating Temperature | Maximum Operating Pressure | Connection Type | Depth | Width | Height | Weight | Maximum Flow Rate | Minimum Operating Pressure | Port Connection | Micron Rating | Filter Type | Drain | Options | Maximum Flow Rate | Maximum Flow Rate (cfm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AA065NDEI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 60 °C | 2 °C | 16 barg | DIN Flange °F | 340 mm | 17.3 inch | 1065 mm | 154 lb | 1312 CFM at 100 psig | 15 psig | DN80 | Down to 0.01 micron | High Efficiency Coalescing | Electronic | Incident Monitor | 2232 m³/h @ 7 barg | 1312 cfm @ 100 psig | ||
| AA065NDEX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 35 °F | 16 barg | DIN Flange °F | 13.4 inch | 440 mm | 42.0 inch | 154 lb | 1312 CFM at 100 psig | 15 psig | DN80 | Down to 0.01 micron | High Efficiency Coalescing | Electronic | None | 2232 m³/h @ 7 barg | 1312 cfm @ 100 psig | ||
| AA065NDMI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 100 °C | 35 °F | 16 barg | DIN Flange °F | 340 mm | 17.3 inch | 1065 mm | 154 lb | 1312 CFM at 100 psig | 1 barg | DN80 | Down to 0.01 micron | Dry Particulate | Manual | Incident Monitor | 2232 m³/h @ 7 barg | 1312 cfm @ 100 psig | ||
| AA065NDMX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 35 °F | 16 barg | DIN Flange °F | 340 mm | 17.3 inch | 42.0 inch | 70 kg | 1312 CFM at 100 psig | 15 psig | DN80 | Down to 0.01 micron | Dry Particulate | Manual | None | 2232 m³/h @ 7 barg | 1312 cfm @ 100 psig | ||
| AA070ODEI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 2 °C | 232 psig | DIN Flange °F | 16 inch | 19.7 inch | 45.4 inch | 97 kg | 2625 CFM at 100 psig | 1 barg | DN100 | Down to 0.01 micron | High Efficiency Coalescing | Electronic | Incident Monitor | 4464 m³/h @ 7 barg | 2625 cfm @ 100 psig | ||
| AA070ODEX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 60 °C | 2 °C | 232 psig | DIN Flange °F | 405 mm | 500 mm | 45.4 inch | 97 kg | 2625 CFM at 100 psig | 1 barg | DN100 | Down to 0.01 micron | High Efficiency Coalescing | Electronic | None | 4464 m³/h @ 7 barg | 2625 cfm @ 100 psig | ||
| AA070ODMI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 35 °F | 16 barg | DIN Flange °F | 16 inch | 500 mm | 45.4 inch | 214.0 lb | 2625 CFM at 100 psig | 15 psig | DN100 | Down to 0.01 micron | Dry Particulate | Manual | Incident Monitor | 4464 m³/h @ 7 barg | 2625 cfm @ 100 psig | ||
| AA070ODMX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 2 °C | 16 barg | DIN Flange °F | 16 inch | 500 mm | 1152 mm | 214.0 lb | 2625 CFM at 100 psig | 15 psig | DN100 psig | Down to 0.01 micron | Dry Particulate | Manual | None | 4464 m³/h @ 7 barg | 2625 cfm @ 100 psig | ||
| AA075PDEI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 35 °F | 232 psig | DIN Flange °F | 520 mm | 23.6 inch | 1256 mm | 326 lb | 3939 CFM at 100 psig | 15 psig | DN150 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | Incident Monitor | 6696 m³/h @ 7 barg | 3939 cfm @ 100 psig | ||
| AA075PDEX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 2 °C | 232 psig | DIN Flange °F | 20.5 inch | 23.6 inch | 49.5 inch | 148.0 kg | 3939 CFM at 100 psig | 1 barg | DN150 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | None | 6696 m³/h @ 7 barg | 3939 cfm @ 100 psig | ||
| AA075PDMI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 100 °C | 2 °C | 232 psig | DIN Flange | 520 mm | 600 mm | 49.5 inch | 148.0 kg | 3939 CFM at 100 psig | 15 psig | DN150 psig | Down to 0.01 micron | Dry Particulate | Manual | Incident Monitor | 6696 m³/h @ 7 barg | 3939 cfm @ 100 psig | ||
| AA075PDMX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 35 °F | 16 barg | DIN Flange | 520 mm | 23.6 inch | 49.5 inch | 148.0 kg | 3939 CFM at 100 psig | 15 psig | DN150 psig | Down to 0.01 micron | Dry Particulate | Manual | None | 6696 m³/h @ 7 barg | 3939 cfm @ 100 psig | ||
| AA080PDEI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 35 °F | 232 psig | DIN Flange | 580 mm | 25.6 inch | 1332 mm | 187.0 kg | 5251 CFM at 100 psig | 15 psig | DN150 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | Incident Monitor | 8928 m³/h @ 7 barg | 5251 cfm @ 100 psig | ||
| AA080PDEX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 2 °C | 16 barg | DIN Flange | 22.8 inch | 650 mm | 1332 mm | 412 lb | 5251 CFM at 100 psig | 15 psig | DN150 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | None | 8928 m³/h @ 7 barg | 5251 cfm @ 100 psig | ||
| AA080PDMI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 2 °C | 232 psig | DIN Flange | 580 mm | 650 mm | 52.4 inch | 187.0 kg | 5251 CFM at 100 psig | 1 barg | DN150 psig | Down to 0.01 micron | Dry Particulate | Manual | Incident Monitor | 8928 m³/h @ 7 barg | 5251 cfm @ 100 psig | ||
| AA080PDMX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 2 °C | 232 psig | DIN Flange | 22.8 inch | 650 mm | 52.4 inch | 187.0 kg | 5251 CFM at 100 psig | 1 barg | DN150 psig | Down to 0.01 micron | Dry Particulate | Manual | None | 8928 m³/h @ 7 barg | 5251 cfm @ 100 psig | ||
| AA085QDEI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 140 °F | 2 °C | 232 psig | DIN Flange | 25.2 inch | 29.5 inch | 55.7 inch | 529 lb | 7877 CFM at 100 psig | 15 psig | DN200 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | Incident Monitor | 13392 m³/h @ 7 barg | 7877 cfm @ 100 psig | ||
| AA085QDEX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 60 °C | 35 °F | 232 psig | DIN Flange | 25.2 inch | 750 mm | 55.7 inch | 529 lb | 7877 CFM at 100 psig | 15 psig | DN200 psig | Down to 0.01 micron | High Efficiency Coalescing | Electronic | None | 13392 m³/h @ 7 barg | 7877 cfm @ 100 psig | ||
| AA085QDMI | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 212 °F | 2 °C | 16 barg | DIN Flange | 25.2 inch | 29.5 inch | 55.7 inch | 240.0 kg | 7877 CFM at 100 psig | 15 psig | DN200 psig | Down to 0.01 micron | Dry Particulate | Manual | Incident Monitor | 13392 m³/h @ 7 barg | 7877 cfm @ 100 psig | ||
| AA085QDMX | Quote Required | TBD | Parker | Gas Separation and Filtration Division EMEA | 100 °C | 2 °C | 16 barg | DIN Flange | 25.2 inch | 750 mm | 55.7 inch | 529 lb | 7877 CFM at 100 psig | 15 psig | DN200 psig | Down to 0.01 micron | Dry Particulate | Manual | None | 13392 m³/h @ 7 barg | 7877 cfm @ 100 psig |