• Availability & Price
  • Search SKU
Filter by attributes
  • Flow Rate
  • For Fluid Type
  • Housing Material
More Filters...
Filter by manufacturer
Manufacturers

Low Pressure Mechanical Flowmeters – Loflow Series

Picture for category Low Pressure Mechanical Flowmeters – Loflow Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker Loflow Series comprises a wide range of inline mechanical flow measurement devices that are designed for low-flow, low-pressure applications. The flowmeters are non-intrusive (i.e., do not obstruct flow) and serve as a low-cost solution for visually verifying small measurements of flow with an accurate reading. Common applications include pharmaceutical manufacturing systems, hospital equipment, swimming pools, water treatment systems,  
Loflow flowmeters are highly simplistic and versatile devices that utilize the tried and tested principle of variable area flow measurement. The meters work in a vertical plane and feature an internal piston / sphere  inside a calibrated tapered bore, which moves as flow rate increases, opening a larger area to pass flowing air, water or hydraulic oil. The design provides users with a direct visual indication of flow rate and serves as a highly reliable method of measuring flow in low-pressure fluid systems. 
Multiple Loflow meters are available to meet the unique fluid flow requirements of customers’ systems, with flow rates range from 0.01 – 22 L/min (0.0026 – 5.8 GPM) and a maximum allowable working pressure of 10 bar (145 psi). All LoFlow devices are calibrated for both oil and water and feature accuracy and repeatability of +-2% full scale defection (FSD) and +-1% FSD, respectively. The meters are relatively insensitive to viscosity changes. 
For information regarding compatibility with corrosive fluids, contact a Parker Filtration representative.
Markets:
Pharmaceutical manufacturing
Water and wastewater treatment
Process 
Applications:
Water and wastewater treatment systems
Pharmaceutical manufacturing systems
Swimming pools
Hospital equipment
Filtration systems
Photography and x-ray equipment
Benefits:
Clear plastic body allows users to quickly and easily determine flow rate in a system and/or line
Helps protect critical equipment from damage by ensuring that hydraulic fluid levels do not go above or below specified levels
Negligible pressure drop characteristics
Easy panel mounting assembly and simple to use
Features:
Capable of flows ranging from 0.01 – 22 L/min (0.0026 – 5.8 GPM) 
Maximum working temperature +60°C (+140°F) 
Maximum allowable working pressure: 10 bar (145 psi)
Calibrated for both oil and water
Large-scale definition for precise measurement
Negligible pressure drop characteristics
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceWeightWidthAccuracyMaterials of ConstructionElectrical RequirementsOperating PressurePort TypeSensing MethodCycle TimeSpecifications MetOperating TemperatureSignal OutputDiameterOperating HumidityTechnologyMaximum Fluid TemperatureMinimum Fluid TemperatureHeightDivisionBody MaterialProduct StyleSeal MaterialIndustryDivisionFor Fluid TypeATEX Specifications MetPort SizeBrandCommunication InterfaceIngress Protection RatingProduct TypeLengthFlow RateFor Fluid TypeHousing MaterialFlow Rate
LF801411
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDStainless Steeln/a10 barBSPTVariable Orifice Flow Metern/aPressure Directive60 °Cn/an/an/aFiltration140 °F+5 °C39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aIndustrial Manufacturing EquipmentHydraulic & Industrial Process Filtration Division EMEAWatern/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm0.06 to 0.55 L/minWaterStainless Steel0.06 to 0.55 l/min
LF801431
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDPVCn/a145 psiBSPTVariable Orifice Flow Metern/aPressure Directive60 °Cn/an/an/aFiltration60 °C+5 °C39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aIndustrial Manufacturing EquipmentHydraulic & Industrial Process Filtration Division EMEAOiln/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm0.01 to 0.2 L/minOilStainless Steel0.01 to 0.2 l/min
LF802412
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDPVCn/a10 barBSPTVariable Orifice Flow Metern/aPressure Directive140 °Fn/an/an/aFiltration60 °C+40 °F39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aIndustrial Manufacturing EquipmentHydraulic & Industrial Process Filtration Division EMEAWatern/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm0.2 to 2 L/minWaterAcetal0.2 to 2 l/min
LF802413
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDPVCn/a10 barBSPTVariable Orifice Flow Metern/aPressure Directive140 °Fn/an/an/aFiltration140 °F+5 °C39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aIndustrial Manufacturing EquipmentHydraulic & Industrial Process Filtration Division EMEAWatern/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm2 to 10 L/minWaterStainless Steel2 to 10 l/min
LF802414
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDABS 7020n/a145 psiBSPTVariable Orifice Flow Metern/aPressure Directive140 °Fn/an/an/aFiltration140 °F+5 °C39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aOff-road MachineryHydraulic & Industrial Process Filtration Division EMEAWatern/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm3 to 22 L/minWaterStainless Steel3 to 22 l/min
LF802432
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDStainless Steeln/a145 psiBSPTVariable Orifice Flow Metern/aPressure Directive140 °Fn/an/an/aFiltration140 °F+40 °F39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aOff-road MachineryHydraulic & Industrial Process Filtration Division EMEAOiln/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm0.1 to 0.9 L/minOilAcetal0.1 to 0.9 l/min
LF802434
Quote Required
TBD
0.14 kg40 mm+/- 2% typical FSDStainless Steeln/a10 barBSPTVariable Orifice Flow Metern/aPressure Directive60 °Cn/an/an/aFiltration60 °C+5 °C39 mmHydraulic & Industrial Process Filtration Division EMEAGrillon TR55Flow Metern/aIndustrial & Chemical ProcessingHydraulic & Industrial Process Filtration Division EMEAOiln/a1/4 to 3/4 inchParkern/aN/ACondition Monitor216 mm1 to 9 L/minOilStainless Steel1 to 9 l/min