- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Lever Operated Directional Control Valve - D61VL Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Options | Division | Maximum Operating Pressure | Weight | Body Material | Maximum Flow Rate | Valve Type | Size | Minimum Operating Temperature | Pilot Inlet / Drain Locations | Seal Material | Spool Code | Actuation Type | Spool Position | Mounting Type | Maximum Operating Temperature | Maximum Operating Pressure | Size | Maximum Flow Rate | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D61VL002D1N | Quote Required | TBD | n/a | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1N60 | Quote Required | TBD | Pilot Choke Meter-in | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1N7 | Quote Required | TBD | Pilot Choke Meter-out | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1N8 | Quote Required | TBD | Stroke Adjust B End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1N89 | Quote Required | TBD | Stroke Adjust A and B Ends | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1N9 | Quote Required | TBD | Stroke Adjust A End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V | Quote Required | TBD | n/a | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V60 | Quote Required | TBD | Pilot Choke Meter-in | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V7 | Quote Required | TBD | Pilot Choke Meter-out | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V8 | Quote Required | TBD | Stroke Adjust B End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V89 | Quote Required | TBD | Stroke Adjust A and B Ends | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | All Ports Open | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D1V9 | Quote Required | TBD | Stroke Adjust A End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | Internal Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N | Quote Required | TBD | n/a | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N60 | Quote Required | TBD | Pilot Choke Meter-in | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N7 | Quote Required | TBD | Pilot Choke Meter-out | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N8 | Quote Required | TBD | Stroke Adjust B End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N89 | Quote Required | TBD | Stroke Adjust A and B Ends | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2N9 | Quote Required | TBD | Stroke Adjust A End | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Nitrile | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2V | Quote Required | TBD | n/a | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate | ||
| D61VL002D2V60 | Quote Required | TBD | Pilot Choke Meter-in | Hydraulic Valve Systems Division | 3000 | 26.7 | Gray Iron | 100 | Lever Operated Directional Control Valve | NFPA D08 | -4 | External Pilot / External Drain | Fluorocarbon | 4-Way | Hydraulic Pressure | Double Operator | Subplate | 140 | 3000 PSI | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | Subplate |