- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Lever Operated Directional Control Valve - D61VL Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Seal Material | Maximum Operating Temperature | Division | Maximum Operating Pressure | Minimum Operating Temperature | Actuation Type | Maximum Flow Rate | Options | Mounting Type | Size | Body Material | Spool Code | Spool Position | Pilot Inlet / Drain Locations | Valve Type | Weight | Maximum Operating Pressure | Mounting Type | Size | Maximum Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D61VL001B1N | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | n/a | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1N60 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-in | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1N7 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-out | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1N8 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust B End | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1N89 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A and B Ends | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1N9 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A End | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | n/a | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V60 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-in | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V7 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-out | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V8 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust B End | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V89 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A and B Ends | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B1V9 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A End | Subplate | NFPA D08 | Gray Iron | All Ports Blocked | Single Operator | Internal Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N | Quote Required | TBD | Nitrile | 140 °F | Hydraulic Valve Systems Division | 207 bar | -4 °F | Hydraulic Pressure | 100 Gal/min | n/a | Subplate | CETOP 8 | Gray Iron | 3-Position | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 12.1 kg | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N60 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-in | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N7 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-out | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N8 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust B End | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N89 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A and B Ends | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2N9 | Quote Required | TBD | Nitrile | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Stroke Adjust A End | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2V | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | n/a | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool | ||
| D61VL001B2V60 | Quote Required | TBD | Fluorocarbon | 140 | Hydraulic Valve Systems Division | 3000 | -4 | Hydraulic Pressure | 100 | Pilot Choke Meter-in | Subplate | NFPA D08 | Gray Iron | 4-Way | Single Operator | External Pilot / External Drain | Lever Operated Directional Control Valve | 26.7 | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | Up to 100 GPM depending on spool |