Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSizeSeal MaterialMinimum Operating TemperatureSpool CodeMaximum Operating TemperatureActuation TypeSpool PositionPilot Inlet / Drain LocationsMounting TypeWeightDivisionMaximum Operating PressureBody MaterialMaximum Flow RateValve TypeOptionsMounting TypeSizeMaximum Flow RateMaximum Operating Pressure
D61VL002B2N
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control Valven/aSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2N60
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-inSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2N7
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-outSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2N8
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust B EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2N89
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A and B EndsSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2N9
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control Valven/aSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V60
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-inSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V7
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-outSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V8
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust B EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V89
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A and B EndsSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B2V9
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / External DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control Valven/aSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N60
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-inSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N7
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-outSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N8
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust B EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N89
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A and B EndsSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5N9
Quote Required
TBD
NFPA D08Nitrile-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValveStroke Adjust A EndSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5V
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control Valven/aSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI
D61VL002B5V60
Quote Required
TBD
NFPA D08Fluorocarbon-44-Way140Hydraulic PressureSingle OperatorExternal Pilot / Internal DrainSubplate26.7Hydraulic Valve Systems Division3000Gray Iron100Lever Operated Directional Control ValvePilot Choke Meter-inSubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool3000 PSI