- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate (m³/h)
- Pre-Installed Optional Accessories
Filter by manufacturer
KE-MT Series Large Flow Heatless Compressed Air Dryer
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker KE-MT Series heatless adsorption dryers are designed to supply high quality dry compressed air reliably and efficiently down to a pressure dew point of -70 °C. They are capable of volume flows of up to 6100m³/h at operating conditions of 7 barg (100psig).
The KE-MT Series is offered with energy saving dew point dependent switching (DDS) as an option. Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available. In such an operating mode, the changeover cycle between vessels only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated vessel occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration and consequently provides significant energy savings.
When there is a further requirement for compressed air to be delivered free from oil vapour and odours, as well as clean and dry, the units can be supplied with an additional third vessel filled with activated carbon, the KEA-MT Series. KEA-MT is ideal for use in laboratory, food, beverage and pharmaceutical applications.
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the product information sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...The KE-MT Series is offered with energy saving dew point dependent switching (DDS) as an option. Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available. In such an operating mode, the changeover cycle between vessels only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated vessel occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration and consequently provides significant energy savings.
When there is a further requirement for compressed air to be delivered free from oil vapour and odours, as well as clean and dry, the units can be supplied with an additional third vessel filled with activated carbon, the KEA-MT Series. KEA-MT is ideal for use in laboratory, food, beverage and pharmaceutical applications.
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the product information sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Controller Type | Brand | Height | Pressure Dew Point | Power Consumption | Maximum Ambient Temperature | Ingress Protection Rating | Minimum Operating Temperature | Connection Type | Maximum Flow Rate | Maximum Operating Temperature | Specifications Met | Compatible After Filter | Division | Electrical Requirements | Maximum Operating Pressure | Depth | Minimum Ambient Temperature | Minimum Operating Pressure | Compatible Prefilter | Port Size | Weight | Width | Product Type | Pre-Installed Optional Accessories | Maximum Flow Rate (m³/h) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| K120/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2080 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 706 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX050I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 840 mm | 1.5 °C | 5 barg | OIL-X AOPX050I and AAPX050I | DN50 | 640 kg | 1060 mm | Heatless | N/A | 1200 @ 7 barg / PDP -25°C | ||
| K120/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2080 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 706 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX050I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 840 mm | 1.5 °C | 5 barg | OIL-X AOPX050I and AAPX050I | DN50 | 640 kg | 1060 mm | Heatless | Dew Point Sensor | 1200 @ 7 barg / PDP -25°C | ||
| K150/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2120 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 912 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX050I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 900 mm | 1.5 °C | 5 barg | OIL-X AOPX050I and AAPX050I | DN65 | 770 kg | 1270 mm | Heatless | N/A | 1550 @ 7 barg / PDP -25°C | ||
| K150/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2120 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 912 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX050I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 900 mm | 1.5 °C | 5 barg | OIL-X AOPX050I and AAPX050I | DN65 | 770 kg | 1270 mm | Heatless | Dew Point Sensor | 1550 @ 7 barg / PDP -25°C | ||
| K200/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2160 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 1177 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX055I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 990 mm | 1.5 °C | 5 barg | OIL-X AOPX055I and AAPX055I | DN65 | 955 kg | 1350 mm | Heatless | N/A | 2000 @ 7 barg / PDP -25°C | ||
| K200/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2160 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 1177 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX055I | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 990 mm | 1.5 °C | 5 barg | OIL-X AOPX055I and AAPX055I | DN65 | 955 kg | 1350 mm | Heatless | Dew Point Sensor | 2000 @ 7 barg / PDP -25°C | ||
| K250/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2210 mm | -25 to -70 °C | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 1471 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX060K | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1040 mm | 1.5 °C | 5 barg | OIL-X AOPX060K and AAPX060K | DN80 | 1075 kg | 1530 mm | Heatless | N/A | 2500 @ 7 barg / PDP -25°C | ||
| K250/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2210 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 1471 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX060K | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1040 mm | 1.5 °C | 5 barg | OIL-X AOPX060K and AAPX060K | DN80 | 1075 kg | 1530 mm | Heatless | Dew Point Sensor | 2500 @ 7 barg / PDP -25°C | ||
| K300/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2255 mm | -25 to -70 °C | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 1766 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX060K | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1100 mm | 1.5 °C | 72.5 psig | OIL-X AOPX060K and AAPX060K | DN80 | 1500 kg | 1600 mm | Heatless | N/A | 3000 @ 7 barg / PDP -25°C | ||
| K300/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2255 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 1766 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AOPX060K | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1100 mm | 1.5 °C | 72.5 psig | OIL-X AOPX060K and AAPX060K | DN80 | 1500 kg | 1600 mm | Heatless | Dew Point Sensor | 3000 @ 7 barg / PDP -25°C | ||
| K380/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2385 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 2237 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO070O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 1200 mm | 1.5 °C | 72.5 psig | OIL-X AO070O and AA070O | DN100 | 1990 kg | 1875 mm | Heatless | N/A | 3800 @ 7 barg / PDP -25°C | ||
| K380/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2385 mm | -25 to -70 °C | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 2237 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO070O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1200 mm | 1.5 °C | 72.5 psig | OIL-X AO070O and AA070O | DN100 | 1990 kg | 1875 mm | Heatless | Dew Point Sensor | 3800 @ 7 barg / PDP -25°C | ||
| K500/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2660 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 25 °C | Flanged according to EN1092-1 | 2855 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO075O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 1250 mm | 1.5 °C | 5 barg | OIL-X AO075O and AA075O | DN100 | 2410 kg | 1925 mm | Heatless | N/A | 4850 @ 7 barg / PDP -25°C | ||
| K500/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2660 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 2855 CFM at 101 psig, PDP -13°F | 50 °C | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO075O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 145 psig | 1250 mm | 1.5 °C | 72.5 psig | OIL-X AO075O and AA075O | DN100 | 2410 kg | 1925 mm | Heatless | Dew Point Sensor | 4850 @ 7 barg / PDP -25°C | ||
| K600/10D1-F230M | Quote Required | TBD | Multitronic | Parker | 2820 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 3590 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO075O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 1565 mm | 1.5 °C | 5 barg | OIL-X AO075O and AA075O | DN125 | 2850 kg | 2160 mm | Heatless | N/A | 6100 @ 7 barg / PDP -25°C | ||
| K600/10D1-F230MT | Quote Required | TBD | Multitronic | Parker | 2820 mm | -13 to -97 °F | 7.2 VA | 50 °C | 54 | 77 °F | Flanged according to EN1092-1 | 3590 CFM at 101 psig, PDP -13°F | 122 °F | PED 97/23/EG Module D+B Category II, others on request | OIL-X AO075O | Gas Separation and Filtration Division EMEA | 230V, 50-60Hz | 10 barg | 1565 mm | 1.5 °C | 5 barg | OIL-X AO075O and AA075O | DN125 | 2850 kg | 2160 mm | Heatless | Dew Point Sensor | 6100 @ 7 barg / PDP -25°C |