- Availability & Price
- Search SKU
Filter by attributes
- Flow Rate
- Optional Accessories
- Port Size
Filter by manufacturer
K-MT 10-95 Series Heatless Compressed Air Dryer
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker K-MT 10-95 range of heatless adsorption dryers are designed to dry industrial compressed air reliably and efficiently down to a pressure dew point of -70°C. The units are compact and are designed to be installed free standing. They come equipped with integrated high performance OIL-X pre- and post filtration and are capable of volume flows up to 940 m³/h @ 7 barg (100 psig).
Features
• Pressure dew points down to -70°C
• Volume flows up to 940m³/h @ 7 barg (3600 cfm @ 102 psig)
• High performance OIL-X pre- and post filters installed as standard
• Energy saving dew point dependent switching (DDS) as an option
Benefits
• Highest quality air
• Energy efficient
• Very flexible due to a wide range of options and accessories
Energy Savings
Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option. In such an operating mode, the changeover cycle between chambers only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated chamber occur. This feature enables the drying phase to be lengthened and thus avoids unnecessary use of purge air for regeneration and consequently provides energy savings.
Compressed air can be selectively dried to meet a dew point of -25°C down to -70°C.
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Features
• Pressure dew points down to -70°C
• Volume flows up to 940m³/h @ 7 barg (3600 cfm @ 102 psig)
• High performance OIL-X pre- and post filters installed as standard
• Energy saving dew point dependent switching (DDS) as an option
Benefits
• Highest quality air
• Energy efficient
• Very flexible due to a wide range of options and accessories
Energy Savings
Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option. In such an operating mode, the changeover cycle between chambers only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated chamber occur. This feature enables the drying phase to be lengthened and thus avoids unnecessary use of purge air for regeneration and consequently provides energy savings.
Compressed air can be selectively dried to meet a dew point of -25°C down to -70°C.
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Brand | Specifications Met | Division | Product Type | Width | Weight | Depth | Height | Electrical Requirements | Ambient Temperature | Division | Connection Type | ISO Grade | Application | Product Series | Technology | Operating Temperature | Operating Pressure | Product Style | Industry | Noise Level | Ingress Protection Rating | Port Size | Flow Rate | Optional Accessories |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| K10/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1118.0 mm | 355 lb | 466.0 mm | 56 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 105 m³/h @7 barg (62 cfm @102 psig) | None | ||
| K10/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1118.0 mm | 161 kg | 466.0 mm | 1411.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 105 m³/h @7 barg (62 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K15/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1118.0 mm | 193 kg | 18 inch | 1740.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 145 m³/h @7 barg (85 cfm @102 psig) | None | ||
| K15/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1118.0 mm | 425 lb | 18 inch | 69 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 145 m³/h @7 barg (85 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K20/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 37 inch | 425 lb | 18 inch | 60 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 200 m³/h @7 barg (118 cfm @102 psig) | None | ||
| K20/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 37 inch | 425 lb | 466.0 mm | 60 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1 inch | 200 m³/h @7 barg (118 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K25/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 36 inch | 234 kg | 506.0 mm | 68 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 255 m³/h @7 barg (150 cfm @102 psig) | None | ||
| K25/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 926.0 mm | 234 kg | 20 inch | 1735.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 255 m³/h @7 barg (150 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K35/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1213.0 mm | 283 kg | 534.0 mm | 1783.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 350 m³/h @7 barg (206 cfm @102 psig) | None | ||
| K35/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1213.0 mm | 624 lb | 21 inch | 70 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 350 m³/h @7 barg (206 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K45/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 49 inch | 334 kg | 555.0 mm | 71 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 420 m³/h @7 barg (247 cfm @102 psig) | None | ||
| K45/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 1245.0 mm | 334 kg | 555.0 mm | 71 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 1½ inch | 420 m³/h @7 barg (247 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K60/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 51 inch | 944 lb | 24 inch | 73 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2 inch | 620 m³/h @7 barg (365 cfm @102 psig) | None | ||
| K60/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 51 inch | 428 kg | 607.0 mm | 73 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2 inch | 620 m³/h @7 barg (365 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K75/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 57 inch | 555 kg | 628.0 mm | 78 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2 inch | 750 m³/h @7 barg (441 cfm @102 psig) | None | ||
| K75/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 57 inch | 1224 lb | 25 inch | 78 inch | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 5 to 50 °C | 58 to 232 psig | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2 inch | 750 m³/h @7 barg (441 cfm @102 psig) | Pre-installed Dew Point Sensor | ||
| K95/16D3-G230M | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 59 inch | 1589 lb | 658.0 mm | 2001.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 122.0 °F Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2½ inch | 940 m³/h @7 barg (553 cfm @102 psig) | None | ||
| K95/16D3-G230MT | Quote Required | TBD | Parker | PED 2014/68/EU Fluid Group II<br/> Others on request. | Gas Separation and Filtration Division EMEA | Compressed Air Dryer | 59 inch | 1589 lb | 658.0 mm | 2001.0 mm | Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC | 50.0 °C Maximum | Gas Separation and Filtration Division EMEA | BSPP | Standard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2 | Compressed Air Applications | K-MT 10-95 | Filtration | 41 to 122 °F | 4 to 16 barg | Heatless | Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 65 to 86 dBA | IP65 Indoor and Frost Free Installation Only | 2½ inch | 940 m³/h @7 barg (553 cfm @102 psig) | Pre-installed Dew Point Sensor |