• Availability & Price
  • Search SKU
Filter by attributes
  • Filter Element Type
  • Maximum Flow Rate
  • Micron Rating
  • Port Size
  • Port Type
More Filters...
Filter by manufacturer
Manufacturers

Hyperfilter Compressed Air Filters (For Pressures Up To 16 Bar G)

Picture for category Hyperfilter Compressed Air Filters (For Pressures Up To 16 Bar G)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air incorporates a high concentration of dirt, oil, moisture and other impurities. Failure to remove these contaminants will lead to escalating maintenance costs, lengthy downtimes and damaged finished goods.

Hyperfilter coalescing, dry particulate and oil vapour removal filters have been specifically designed to prevent these undesired effects, offering a comprehensive range of compressed air filters covering all industrial needs.

Available in 5 filter grades: Coarse pre-filter, general purpose and high efficiency coalescing filters, dry particulate filter and oil vapour removal filter.

Product Features / Benefits:
• Protects tools and downstream equipment

• Increases efficiency, reduces downtimes

• Significantly reduces maintenance costs

• Full range of models and filtration grades for all industrial applications

Accessories & Options
• Kit for installation in series of two or more filters;

• Wall mounting kit

• Element supervision indicator

• Differential pressure gauge

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionFilter Element TypePort TypeMaximum Flow RateMicron RatingPort SizeResidual Oil ContentElement Change IntervalHeightMaximum Flow RateMaximum Operating PressureMinimum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureBrandWeightWidthCompatible ElementApplicationDrain
HFN175
Quote Required
TBD
Gas Separation and Filtration Division EMEANone (housing only)BSPPN/An/a2 inch
HFN175CWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAOil Vapour RemovalBSPP1050 m³/hourn/a2 inch0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)When oil vapour or odour is detected928 mm618 CFM16 barg1 barg65 °C36 °FHiross14.3 lb5.9 inchC175-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN175DWD
Quote Required
TBD
Gas Separation and Filtration Division EMEADry ParticulateBSPP1050 m³/hourDown to 3 micron2 inchN/A12 Months928 mm618 CFM16 barg15 psig149 °F2 °CHiross6.5 kg5.9 inchQ175-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN175PWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAGeneral Purpose CoalescingBSPP1050 m³/hourDown to 1 micron2 inch0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)12 Months928 mm618 CFM232 psig15 psig65 °C2 °CHiross14.3 lb5.9 inchP175-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN175QWD
Quote Required
TBD
Gas Separation and Filtration Division EMEACoarse Pre-filterBSPP1050 m³/hourDown to 3 micron2 inchN/A12 Months928 mm618 CFM16 barg1 barg149 °F2 °CHiross14.3 lb5.9 inchQ175-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN175SWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAHigh Efficiency CoalescingBSPP1050 m³/hourDown to 0.01 micron2 inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)12 Months36.5 inch618 CFM232 psig1 barg65 °C36 °FHiross14.3 lb5.9 inchS175-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN205
Quote Required
TBD
Gas Separation and Filtration Division EMEANone (housing only)BSPPN/An/a2 inch
HFN205CWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAOil Vapour RemovalBSPP1230 m³/hourn/a2 inch0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)When oil vapour or odour is detected36.5 inch723.9 CFM16 barg1 barg65 °C2 °CHiross6.6 kg5.9 inchC205-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN205DWD
Quote Required
TBD
Gas Separation and Filtration Division EMEADry ParticulateBSPP1230 m³/hourDown to 3 micron2 inchN/A12 Months928 mm723.9 CFM16 barg1 barg65 °C36 °FHiross14.6 lb150 mmQ205-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN205PWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAGeneral Purpose CoalescingBSPP1230 m³/hourDown to 1 micron2 inch0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)12 Months36.5 inch723.9 CFM16 barg15 psig65 °C36 °FHiross14.6 lb5.9 inchP205-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN205QWD
Quote Required
TBD
Gas Separation and Filtration Division EMEACoarse Pre-filterBSPP1230 m³/hourDown to 3 micron2 inchN/A12 Months36.5 inch723.9 CFM232 psig1 barg65 °C2 °CHiross14.6 lb150 mmQ205-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN205SWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAHigh Efficiency CoalescingBSPP1230 m³/hourDown to 0.01 micron2 inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)12 Months36.5 inch723.9 CFM16 barg15 psig65 °C2 °CHiross14.6 lb5.9 inchS205-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN300
Quote Required
TBD
Gas Separation and Filtration Division EMEANone (housing only)BSPPN/An/a2½ inch
HFN300CWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAOil Vapour RemovalBSPP1800 m³/hourn/a2½ inch0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)When oil vapour or odour is detected733 mm1059.4 CFM16 barg15 psig149 °F2 °CHiross29.7 lb7.4 inchC300-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN300DWD
Quote Required
TBD
Gas Separation and Filtration Division EMEADry ParticulateBSPP1800 m³/hourDown to 3 micron2½ inchN/A12 Months28.9 inch1059.4 CFM16 barg1 barg65 °C36 °FHiross13.5 kg188 mmQ300-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN300PWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAGeneral Purpose CoalescingBSPP1800 m³/hourDown to 1 micron2½ inch0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)12 Months28.9 inch1059.4 CFM16 barg15 psig65 °C2 °CHiross13.5 kg188 mmP300-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN300QWD
Quote Required
TBD
Gas Separation and Filtration Division EMEACoarse Pre-filterBSPP1800 m³/hourDown to 3 micron2½ inchN/A12 Months733 mm1059.4 CFM232 psig15 psig65 °C2 °CHiross29.7 lb188 mmQ300-ELZFiltration of compressed air and nitrogen gasManual Drain
HFN300SWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAHigh Efficiency CoalescingBSPP1800 m³/hourDown to 0.01 micron2½ inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)12 Months28.9 inch1059.4 CFM232 psig15 psig65 °C2 °CHiross13.5 kg188 mmS300-ELZFiltration of compressed air and nitrogen gasHDF120 Float Drain
HFN370
Quote Required
TBD
Gas Separation and Filtration Division EMEANone (housing only)BSPPN/An/a3 inch
HFN370CWD
Quote Required
TBD
Gas Separation and Filtration Division EMEAOil Vapour RemovalBSPP2220 m³/hourn/a3 inch0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)When oil vapour or odour is detected933 mm1306.6 CFM232 psig15 psig149 °F36 °FHiross16 kg7.4 inchC370-ELZFiltration of compressed air and nitrogen gasManual Drain