Hyperfilter Compressed Air Filters (For Pressures Up To 16 Bar G)

Picture for category Hyperfilter Compressed Air Filters (For Pressures Up To 16 Bar G)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air incorporates a high concentration of dirt, oil, moisture and other impurities. Failure to remove these contaminants will lead to escalating maintenance costs, lengthy downtimes and damaged finished goods.

Hyperfilter coalescing, dry particulate and oil vapour removal filters have been specifically designed to prevent these undesired effects, offering a comprehensive range of compressed air filters covering all industrial needs.

Available in 5 filter grades: Coarse pre-filter, general purpose and high efficiency coalescing filters, dry particulate filter and oil vapour removal filter.

Product Features / Benefits:
• Protects tools and downstream equipment

• Increases efficiency, reduces downtimes

• Significantly reduces maintenance costs

• Full range of models and filtration grades for all industrial applications

Accessories & Options
• Kit for installation in series of two or more filters;

• Wall mounting kit

• Element supervision indicator

• Differential pressure gauge

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceCompatible ElementElement Change IntervalMaximum Operating PressureMinimum Operating TemperatureApplicationMaximum Operating TemperatureWidthResidual Oil ContentHeightMinimum Operating PressureMaximum Flow RateDrainWeightBrandDivisionPort TypeFilter Element TypeMicron RatingMaximum Flow RatePort Size
HFN062QWD
Quote Required
TBD
Q072-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas65 °C109 mmN/A514 mm15 psig218.9 CFMManual Drain3 kgHirossGas Separation and Filtration Division EMEABSPPCoarse Pre-filterDown to 3 micron372 m³/hour1¼ inch
HFN062SWD
Quote Required
TBD
S072-ELZ12 Months232 psig36 °FFiltration of compressed air and nitrogen gas149 °F4.3 inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)20.2 inch15 psig218.9 CFMHDI Float Drain6.6 lbHirossGas Separation and Filtration Division EMEABSPPHigh Efficiency CoalescingDown to 0.01 micron372 m³/hour1¼ inch
HFN072
Quote Required
TBD
Gas Separation and Filtration Division EMEABSPPNone (housing only)n/aN/A1½ inch
HFN072CWD
Quote Required
TBD
C072-ELZWhen oil vapour or odour is detected232 psig2 °CFiltration of compressed air and nitrogen gas65 °C4.3 inch0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)20.2 inch15 psig254.2 CFMManual Drain6.6 lbHirossGas Separation and Filtration Division EMEABSPPOil Vapour Removaln/a432 m³/hour1½ inch
HFN072DWD
Quote Required
TBD
Q072-ELZ12 Months232 psig2 °CFiltration of compressed air and nitrogen gas65 °C4.3 inchN/A514 mm1 barg254.2 CFMManual Drain3 kgHirossGas Separation and Filtration Division EMEABSPPDry ParticulateDown to 3 micron432 m³/hour1½ inch
HFN072PWD
Quote Required
TBD
P072-ELZ12 Months232 psig2 °CFiltration of compressed air and nitrogen gas149 °F109 mm0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)20.2 inch1 barg254.2 CFMHDI Float Drain6.6 lbHirossGas Separation and Filtration Division EMEABSPPGeneral Purpose CoalescingDown to 1 micron432 m³/hour1½ inch
HFN072QWD
Quote Required
TBD
Q072-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas149 °F4.3 inchN/A20.2 inch15 psig254.2 CFMManual Drain3 kgHirossGas Separation and Filtration Division EMEABSPPCoarse Pre-filterDown to 3 micron432 m³/hour1½ inch
HFN072SWD
Quote Required
TBD
S072-ELZ12 Months232 psig2 °CFiltration of compressed air and nitrogen gas65 °C109 mm0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)20.2 inch15 psig254.2 CFMHDI Float Drain6.6 lbHirossGas Separation and Filtration Division EMEABSPPHigh Efficiency CoalescingDown to 0.01 micron432 m³/hour1½ inch
HFN122
Quote Required
TBD
Gas Separation and Filtration Division EMEABSPPNone (housing only)n/aN/A1½ inch
HFN122CWD
Quote Required
TBD
C135-ELZWhen oil vapour or odour is detected16 barg36 °FFiltration of compressed air and nitrogen gas65 °C150 mm0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)21.7 inch15 psig430.8 CFMManual Drain5.2 kgHirossGas Separation and Filtration Division EMEABSPPOil Vapour Removaln/a732 m³/hour1½ inch
HFN122DWD
Quote Required
TBD
Q135-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas65 °C150 mmN/A550 mm15 psig430.8 CFMManual Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPDry ParticulateDown to 3 micron732 m³/hour1½ inch
HFN122PWD
Quote Required
TBD
P135-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas149 °F150 mm0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)21.7 inch1 barg430.8 CFMHDF120 Float Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPGeneral Purpose CoalescingDown to 1 micron732 m³/hour1½ inch
HFN122QWD
Quote Required
TBD
Q135-ELZ12 Months16 barg36 °FFiltration of compressed air and nitrogen gas65 °C150 mmN/A21.7 inch1 barg430.8 CFMManual Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPCoarse Pre-filterDown to 3 micron732 m³/hour1½ inch
HFN122SWD
Quote Required
TBD
S135-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas149 °F5.9 inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)21.7 inch15 psig430.8 CFMHDF120 Float Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPHigh Efficiency CoalescingDown to 0.01 micron732 m³/hour1½ inch
HFN135
Quote Required
TBD
Gas Separation and Filtration Division EMEABSPPNone (housing only)n/aN/A2 inch
HFN135CWD
Quote Required
TBD
C135-ELZWhen oil vapour or odour is detected232 psig2 °CFiltration of compressed air and nitrogen gas65 °C150 mm0.003 mg/m³ - 0.003 ppm(w) @ 21°C (70°F)550 mm15 psig476.7 CFMManual Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPOil Vapour Removaln/a810 m³/hour2 inch
HFN135DWD
Quote Required
TBD
Q135-ELZ12 Months232 psig2 °CFiltration of compressed air and nitrogen gas149 °F150 mmN/A21.7 inch15 psig476.7 CFMManual Drain5.2 kgHirossGas Separation and Filtration Division EMEABSPPDry ParticulateDown to 3 micron810 m³/hour2 inch
HFN135PWD
Quote Required
TBD
P135-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas149 °F5.9 inch0.5 mg/m³ - 0.5 ppm(w) @ 21°C (70°F)550 mm15 psig476.7 CFMHDF120 Float Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPGeneral Purpose CoalescingDown to 1 micron810 m³/hour2 inch
HFN135QWD
Quote Required
TBD
Q135-ELZ12 Months232 psig36 °FFiltration of compressed air and nitrogen gas149 °F5.9 inchN/A21.7 inch1 barg476.7 CFMManual Drain11.5 lbHirossGas Separation and Filtration Division EMEABSPPCoarse Pre-filterDown to 3 micron810 m³/hour2 inch
HFN135SWD
Quote Required
TBD
S135-ELZ12 Months16 barg2 °CFiltration of compressed air and nitrogen gas65 °C5.9 inch0.01 mg/m³ - 0.01 ppm(w) @ 21°C (70°F)21.7 inch15 psig476.7 CFMHDF120 Float Drain5.2 kgHirossGas Separation and Filtration Division EMEABSPPHigh Efficiency CoalescingDown to 0.01 micron810 m³/hour2 inch