Hypercool Air Cooled Aftercooler
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker Hiross Hypercool range of air cooled aftercoolers represents a cost effective solution to easily remove water vapour from compressed air and cool it to safe usable levels for many industrial applications.
Hypercool air cooled aftercoolers can be used when cooling water is not available, limiting costs and plant complexity and will prepare the air for further filtration and drying. The aftercoolers can be installed immediately downstream of compressors or blowers in order to remove up to 80% of the condensate, protecting the entire compressed air system or production process.
A high quality aftercooler, properly sized is an excellent investment that can help ensure that the compressed air system works efficiently, thereby guaranteeing the quality of the finished product.
Features
• Robust construction and compact design
• Low pressure drop design
• Protective grill for fan and heat exchanger
• High efficiency and low noise axial fans
• Standard protection with epoxy powder coating
• Full range of matching centrifugal separators “Hypersep”
• Extensive range of condensate drains “Hyperdrain”
Benefits
• Significant energy and capital investment savings
• Optimised compressed air systems performance
• Reduced maintenance and improved product quality
• Reliability and continuous operation
• Very low pressure drops with optimum cooling performances
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Hypercool air cooled aftercoolers can be used when cooling water is not available, limiting costs and plant complexity and will prepare the air for further filtration and drying. The aftercoolers can be installed immediately downstream of compressors or blowers in order to remove up to 80% of the condensate, protecting the entire compressed air system or production process.
A high quality aftercooler, properly sized is an excellent investment that can help ensure that the compressed air system works efficiently, thereby guaranteeing the quality of the finished product.
Features
• Robust construction and compact design
• Low pressure drop design
• Protective grill for fan and heat exchanger
• High efficiency and low noise axial fans
• Standard protection with epoxy powder coating
• Full range of matching centrifugal separators “Hypersep”
• Extensive range of condensate drains “Hyperdrain”
Benefits
• Significant energy and capital investment savings
• Optimised compressed air systems performance
• Reduced maintenance and improved product quality
• Reliability and continuous operation
• Very low pressure drops with optimum cooling performances
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Product Series | Weight | Micron Rating | Operating Pressure | Width | Division | Industry | Noise Level | Depth | Technology | Maximum Air Inlet Temperature | Product Style | Product Type | Brand | Division | Application | Height | Connection Type | Flow Rate | Electrical Requirements | Port Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ADS000 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 31 lb | Not Applicable | 16 barg (max.) | 475 mm | Gas Separation and Filtration Division EMEA | Electronics | 33.2 dBA | 216 mm | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 794 mm | BSPP | 36 m³/h @ 7 barg (21 cfm @102 psig) | 230V/1ph/50Hz | ¾" | ||
| ADS001 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 37 lb | Not Applicable | 232 psig (max.) | 545 mm | Gas Separation and Filtration Division EMEA | Automotive | 33.2 dBA | 35.0 inch | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 35.0 inch | BSPP | 72 m³/h @ 7 barg (42 cfm @102 psig) | 230V/1ph/50Hz | ¾" | ||
| ADS003 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 31 kg | Not Applicable | 16 barg (max.) | 28.1 inch | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | 44.1 dBA | 11.9 inch | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 44.8 inch | BSPP | 150 m³/h @ 7 barg (88 cfm @102 psig) | 230V/1ph/50Hz | 1½" | ||
| ADS004 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 37 kg | Not Applicable | 16 barg (max.) | 715 mm | Gas Separation and Filtration Division EMEA | Electronics | 44.1 dBA | 11.9 inch | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 1140 mm | BSPP | 210 m³/h @ 7 barg (124 cfm @102 psig) | 230V/1ph/50Hz | 1½" | ||
| ADT003 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 31 kg | Not Applicable | 16 barg (max.) | 28.1 inch | Gas Separation and Filtration Division EMEA | Electronics | 44.1 dBA | 403 mm | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 44.8 inch | BSPP | 150 m³/h @ 7 barg (88 cfm @102 psig) | 400V/3ph/50Hz | 1½" | ||
| ADT004 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 37 kg | Not Applicable | 16 barg (max.) | 28.1 inch | Gas Separation and Filtration Division EMEA | Pharmaceuticals | 44.1 dBA | 403 mm | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 1140 mm | BSPP | 210 m³/h @ 7 barg (124 cfm @102 psig) | 400V/3ph/50Hz | 1½" | ||
| ADT006 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 58 kg | Not Applicable | 232 psig (max.) | 855 mm | Gas Separation and Filtration Division EMEA | Automotive | 54.2 dBA | 455 mm | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 1315 mm | BSPP | 360 m³/h @ 7 barg (212 cfm @102 psig) | 400V/3ph/50Hz | 1½" | ||
| ADT009 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 70 kg | Not Applicable | 16 barg (max.) | 46.1 inch | Gas Separation and Filtration Division EMEA | Automotive | 58.5 dBA | 18.9 inch | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 1315 mm | BSPP | 540 m³/h @ 7 barg (318 cfm @102 psig) | 400V/3ph/50Hz | 2" | ||
| ADT014 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 233 lb | Not Applicable | 16 barg (max.) | 50.0 inch | Gas Separation and Filtration Division EMEA | Automotive | 62.1 dBA | 20.8 inch | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 61.0 inch | BSPP | 840 m³/h @ 7 barg (494 cfm @102 psig) | 400V/3ph/50Hz | 2" | ||
| ADT018 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 321 lb | Not Applicable | 232 psig (max.) | 67.0 inch | Gas Separation and Filtration Division EMEA | Electronics | 62.6 dBA | 23.2 inch | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 73.5 inch | DN Flange | 1080 m³/h @ 7 barg (636 cfm @102 psig) | 400V/3ph/50Hz | DN 80 | ||
| ADT028 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 398 lb | Not Applicable | 232 psig (max.) | 80.7 inch | Gas Separation and Filtration Division EMEA | Electronics | 70.3 dBA | 24.7 inch | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 74.9 inch | DN Flange | 1680 m³/h @ 7 barg (989 cfm @102 psig) | 400V/3ph/50Hz | DN 80 | ||
| ADT038 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 211 | Not Applicable | 16 barg (max.) | 2263 | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | 70.3 | 590 | Filtration | 200 | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 1975 | DN Flange | 2160 m³/h @ 7 barg (1271 cfm @102 psig) | 400V/3ph/50Hz | DN 100 | ||
| ADT048 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 391 kg | Not Applicable | 232 psig (max.) | 143.4 inch | Gas Separation and Filtration Division EMEA | Pharmaceuticals | 73 dBA | 677 mm | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 88.0 inch | DN Flange | 2880 m³/h @ 7 barg (1695 cfm @102 psig) | 400V/3ph/50Hz | DN 150 | ||
| ADT064 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 944 lb | Not Applicable | 16 barg (max.) | 143.4 inch | Gas Separation and Filtration Division EMEA | Electronics | 73 dBA | 26.6 inch | Filtration | 392 °F | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 2239 mm | DN Flange | 3840 m³/h @ 7 barg (2260 cfm @102 psig) | 400V/3ph/50Hz | DN 150 | ||
| ADT075 | Quote Required | TBD | Hypercool Air Cooled Aftercooler | 476 kg | Not Applicable | 16 barg (max.) | 143.4 inch | Gas Separation and Filtration Division EMEA | Food & Beverage | 73 dBA | 26.6 inch | Filtration | 200 °C | Air Cooled | Aftercooler | Parker | Gas Separation and Filtration Division EMEA | Compressed Air | 88.0 inch | DN Flange | 4500 m³/h @ 7 barg (2649 cfm @102 psig) | 400V/3ph/50Hz | DN 150 |