• Availability & Price
  • Search SKU
Filter by attributes
  • Additional Protection Included
  • Hydraulic Circuit
  • Kit Type
  • Maximum Cooling Capacity
  • Operating Environment
  • Options
  • Output Water Temperature Range
  • Power Supply Voltage
  • Pump Type
  • Water Sensor Option
More Filters...
Filter by manufacturer
Manufacturers

Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications

Picture for category Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Biogas is primarily composed of methane and carbon dioxide with smaller amounts of hydrogen sulphide and ammonia. Trace amounts of other gases like hydrogen, nitrogen or carbon monoxide are also present in the biogas. Usually the mixed gas is saturated with water-vapour and may contain dirt particles. For biogas as a fuel, most of the impurities have to be removed, as they can cause contamination, deposits and damage to equipment. In particular, biogas needs to be dried by cooling it to temperatures close to 5°C (41°F), using water-cooled heat exchangers fed by water chillers. Hyperchill Bioenergy is a key component in this biogas treatment process.

Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.

Features:
• Special protective treatment of condensers and copper piping

• Pump and tank installed inside the chiller

• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime

• Designed to provide cooling water where low temperature water is required as standard

• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications

• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low

• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models

Benefits:
• Compact and easy to install solution

• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites

• High working limits and low running costs

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypeDivisionDivisionPort SizeBrandRefrigerant TypeOperating TemperatureWidthProduct TypeTechnologyCompressor IncludedProduct StyleApplicationProduct SeriesCooling MethodNumber of Axial FansAmbient TemperatureNoise LevelDepthHeightTank CapacityPump TypeWater Sensor OptionPower Supply VoltageAdditional Protection IncludedHydraulic CircuitOperating EnvironmentOutput Water Temperature RangeKit TypeOptionsMaximum Cooling Capacity
ICEP060-WBTP3T0L100031
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c41 to 86 °F33.7 inchProduction Process Water ChillerThermal and Power ManagementHermetic ScrollOpen Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients2118.4< 53 dBA1956 mm1680 mm250 LSingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeWith TankNo Low AmbientWithout Close ControlWithout Fill KitManual External Bypass58.3 kW @ 25°C (63°F)
ICEP060-WBTP3T0L1LW00
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c41 to 86 °F856 mmProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPressurized Closed Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients248< 53 dBA77.0 inch66.1 inch250 LSingle Pump 3 barLow Water400V/3Ph/50HzWithout AntifreezeWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlWithout Fill KitNo Options Selected58.3 kW @ 25°C (63°F)
ICEP060-WBTP3T0L1LW03
Quote Required
TBD
Gas Separation and Filtration Division EMEASingle Pump 3 barLow Water400V/3Ph/50HzWithout AntifreezeWith TankLow Ambient -10°C Fan Step Control)Without Close ControlPressurised Fill KitNo Options Selected58.3 kW @ 25°C (63°F)
ICEP060-WBTP3T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c41 to 86 °F33.7 inchProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPressurized Closed Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients2118.4< 53 dBA1956 mm66.1 inch250 LSingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeWith TankLow Ambient -20°CWithout Close ControlWithout Fill KitNo Options Selected58.3 kW @ 25°C (63°F)
ICEP060-WBTP3T0L20003
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c5 to 30 °C856 mmProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPressurized Closed Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients248< 53 dBA77.0 inch1680 mm250 LSingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeWith TankLow Ambient -20°CWithout Close ControlPressurised Fill KitNo Options Selected58.3 kW @ 25°C (63°F)
ICEP060-WBTP5T0L100A3
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c5 to 30 °C856 mmProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPressurized Closed Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients248< 53 dBA77.0 inch66.1 inch250 LSingle Pump 5 barNo Low Water400V/3Ph/50HzWith AntifreezeWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlPressurised Fill KitNo Options Selected58.3 kW @ 25°C (63°F)
ICEP060-WBTP5T0L20003
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1-1/2 inchHirossR407c5 to 30 °C856 mmProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPressurized Closed Hydraulic CircuitPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients248< 53 dBA1956 mm66.1 inch250 LSingle Pump 5 barNo Low Water400V/3Ph/50HzWithout AntifreezeWith TankLow Ambient -20°CWithout Close ControlPressurised Fill KitNo Options Selected58.3 kW @ 25°C (63°F)