• Availability & Price
  • Search SKU
Filter by attributes
  • Additional Protection Included
  • Hydraulic Circuit
  • Kit Type
  • Maximum Cooling Capacity
  • Operating Environment
  • Options
  • Output Water Temperature Range
  • Power Supply Voltage
  • Pump Type
  • Water Sensor Option
More Filters...
Filter by manufacturer
Manufacturers

Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications

Picture for category Hyperchill BioEnergy Water Chiller for Biogas and Landfill Gas Cooling Applications

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Biogas is primarily composed of methane and carbon dioxide with smaller amounts of hydrogen sulphide and ammonia. Trace amounts of other gases like hydrogen, nitrogen or carbon monoxide are also present in the biogas. Usually the mixed gas is saturated with water-vapour and may contain dirt particles. For biogas as a fuel, most of the impurities have to be removed, as they can cause contamination, deposits and damage to equipment. In particular, biogas needs to be dried by cooling it to temperatures close to 5°C (41°F), using water-cooled heat exchangers fed by water chillers. Hyperchill Bioenergy is a key component in this biogas treatment process.

Extremely compact and easy to use, Hyperchill Bioenergy ensures an accurate control of the water temperature. It has been specifically designed for Biogas applications and provides safe and reliable operation in the harshest of environments, typically found in anaerobic digesters and landfill biogas production areas.

Features:
• Special protective treatment of condensers and copper piping

• Pump and tank installed inside the chiller

• Large built-in water tank that provides a large thermal mass / storage capacity thus reducing the number of refrigerant compressor stop/starts and short cycling and thereby increasing the compressor and chiller lifetime

• Designed to provide cooling water where low temperature water is required as standard

• Use of compliant scroll compressors designed specifically for high efficiency and long life in industrial applications

• Low ambient speed-control on fan-motor ensures constant performances at different temperatures, long lifetime of the fans and a reduction in absorbed power when ambient temperature is low

• Maximum working ambient temperature up to 48°C (118°F) for ICEP models, up to 45°C (113°F) for ICE models

Benefits:
• Compact and easy to install solution

• Reliable operation in the most aggressive of ambient atmospheres at biogas plants and landfill sites

• High working limits and low running costs

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypeDivisionDivisionPort SizeBrandRefrigerant TypeOperating TemperatureProduct StyleProduct TypeTechnologyCompressor IncludedApplicationProduct SeriesCooling MethodAmbient TemperatureNumber of Axial FansDepthWidthHeightTank CapacityNoise LevelPump TypeWater Sensor OptionPower Supply VoltageAdditional Protection IncludedOptionsHydraulic CircuitOperating EnvironmentOutput Water Temperature RangeKit TypeMaximum Cooling CapacityFor Fluid TypeIngress Protection RatingSpecifications MetIndustryWeight
ICEP010-WBTP3T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.4131.7 inch29.8 inch55.3 inch65 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlWithout Fill Kit10.8 kW @ 25°C (63°F)
ICEP014-WBGP5TCFS0000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients48131.7 inch29.8 inch55.3 inch65 L< 53 dBASingle Pump 5 barNo Low Water460V/3Ph/60HzWithout AntifreezeNo Options SelectedWith TankFan Speed Control (Low Ambient -10°C)Close Control +/- 0.5°CWithout Fill Kit14.6 kW @ 25°C (63°F)
ICEP014-WBTP1T0FS0001
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients481806 mm29.8 inch1405 mm65 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankFan Speed Control (Low Ambient -10°C)Without Close ControlAmbient Manual Fill Kit14.6 kW @ 25°C (63°F)
ICEP014-WBTP1T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.4131.7 inch756 mm55.3 inch65 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlWithout Fill Kit14.6 kW @ 25°C (63°F)
ICEP014-WBTP3T0FS0000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients48131.7 inch756 mm55.3 inch65 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankFan Speed Control (Low Ambient -10°C)Without Close ControlWithout Fill Kit14.6 kW @ 25°C (63°F)
ICEP014-WBTP3T0FS0003
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.41806 mm29.8 inch55.3 inch65 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankFan Speed Control (Low Ambient -10°C)Without Close ControlPressurised Fill Kit14.6 kW @ 25°C (63°F)
ICEP014-WBTP3TCL20001
Quote Required
TBD
ThreadedGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA3/4 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementScrollPrecision Cooling of Low Viscosity Industrial Cooling FluidsHyperchill Plus48131.7 inch756 mm55.3 inch65 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CClose Control +/- 0.5°CWithout Fill Kit14.6 kW @ 25°C (63°F)WaterIP54Electromagnetic Directive 2004/108/ECIndustrial Printing175 kg
ICEP020-WBGP1T0L10003C
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm29.8 inch1405 mm100 L< 53 dBASingle Pump 1.5 barNo Low Water460V/3Ph/60HzWithout AntifreezeControl Panel CoverWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlPressurised Fill Kit20.3 kW @ 25°C (63°F)
ICEP020-WBTP1T0L10000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm756 mm55.3 inch100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlWithout Fill Kit20.3 kW @ 25°C (63°F)
ICEP020-WBTP1T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients4821206 mm29.8 inch55.3 inch100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlWithout Fill Kit20.3 kW @ 25°C (63°F)
ICEP020-WBTP1T0L20003
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm756 mm55.3 inch100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlPressurised Fill Kit20.3 kW @ 25°C (63°F)
ICEP020-WBTP3T0L10000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients48247.5 inch756 mm55.3 inch100 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlWithout Fill Kit20.3 kW @ 25°C (63°F)
ICEP020-WBTP3T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients4821206 mm29.8 inch55.3 inch100 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlWithout Fill Kit20.3 kW @ 25°C (63°F)
ICEP024-WBGP3T0L20002
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients48247.5 inch756 mm1405 mm100 L< 53 dBASingle Pump 3 barNo Low Water460V/3Ph/60HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlAmbient Automatic Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBGP3TCL10000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm756 mm55.3 inch100 L< 53 dBASingle Pump 3 barNo Low Water460V/3Ph/60HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Close Control +/- 0.5°CWithout Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBTP1T0FS0000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.4247.5 inch29.8 inch1405 mm100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankFan Speed Control (Low Ambient -10°C)Without Close ControlWithout Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBTP1T0L10000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.4247.5 inch29.8 inch1405 mm100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlWithout Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBTP1T0L10003
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm756 mm55.3 inch100 L< 53 dBASingle Pump 1.5 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlPressurised Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBTP3T0L10000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c5 to 30 °CPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm29.8 inch55.3 inch100 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -10°C (Fan Step Control)Without Close ControlWithout Fill Kit23.6 kW @ 25°C (63°F)
ICEP024-WBTP3T0L20000
Quote Required
TBD
BSPPGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA1 inchHirossR407c41 to 86 °FPressurized Closed Hydraulic CircuitProduction Process Water ChillerThermal and Power ManagementHermetic ScrollPrecision Cooling of Biogas Cooling FluidsHyperchill BioEnergyBioEnergy & Aggressive Ambients118.421206 mm29.8 inch1405 mm100 L< 53 dBASingle Pump 3 barNo Low Water400V/3Ph/50HzWithout AntifreezeNo Options SelectedWith TankLow Ambient -20°CWithout Close ControlWithout Fill Kit23.6 kW @ 25°C (63°F)