High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

Picture for category High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker EPF Series is a high pressure, inline hydraulic oil filter that provides high-efficiency filtration for equipment in demanding environments, including mining, construction, marine, drilling, and agricultural applications. A unique feature of the EPF Series is that the filter element remains inside the filter bowl when performing a change-out. This can save over 500 mm of space envelope in comparison with traditional high pressure filters on the market. The filter element core is also reusable, which reduces waste by up to 50% when compared to conventional filters with non-reusable elements.

EPF Series filters serve as a highly economical filtration solution in high pressure range applications (up to 450 bar), where compact envelopes and excellent fatigue pressure ratings are critical. Specific examples include (but are not limited to) mobile working hydraulics, wind turbines, drive systems, pilot line filtration systems, servo controls, industrial working hydraulics, control systems, and reverse flow valve applications.

The patented design of the filter element allows for integration of the bypass valve and element core as re-usable parts in the filter bowl. This makes the filter secure and eliminates the risk of forgetting to re-install reusable parts during maintenance. Bypass settings are available up to 7 bar (100 psi) or no bypass versions when using patented, high strength filter elements. The principle is based on differential pressure measurement across the filter element.

The EPF Series is designed for use with EPF Series Replacement Elements and is available with various port connection types, filtration media (2, 5, 10, and 20 micron), indicators, and flow capacities (up to 700 L/min) to meet the unique requirements of customers’ hydraulic circuits

Features and Benefits:
• Prevents damaging of hydraulic circuits or machinery done by dirt, sand, dust, metal, etc.

• Lengthens time in between required maintenance intervals, reduces operating costs, and extends overall equipment/machine operational life

• Compact filter design can save over 500 mm of space envelope when compared to traditional inline hydraulic filters

• Reusable element core with patented filtration technology reduces waste by up to 50% when compared to conventional filters with non-reusable elements

• A "clever" design minimizes the likelihood of installation mistakes

• Can be equipped with an optional reverse flow. This valve assembly is integrated in the element end cap and isolates the filter medium during reverse flow conditions.

• Protected aftermarket to guarantee the use of genuine products to protect equipment/machinery.

• Provides OEM branding (labelling)opportunities

• High efficiency Quantµmfiber™ glass media increases particle capture and dirt holding capacity.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandIndustryDivisionDivisionTechnologyFor Fluid TypeSpecifications MetIndicator Pressure SettingApplicationProduct TypeProduct SeriesProduct StyleOperating PressureMaterials of ConstructionSeal MaterialIndicator TypeMicron RatingOptionsFlow RateFilter ElementConnection TypeBypass Valve (bar)Filter Element TypeFlow Capacity (l/min)Port Connection TypeBypass Valve Pressure RatingMounting TypeOperating Temperature
EPF1105QIHBT1MG082
Quote Required
TBD
ParkerOil and GasHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barDeck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC5 µmNo bypass0 to 35 l/min05QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator05QIH (High Strength Microglass)0 to 35G1/2No Bypass with 5.0 bar indicator
EPF1105QIRBPKG08RFV
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorForwardersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug5 µmReverse flow valve incl. Bypass0 to 35 l/min05QIR (Microglass - Reverse Flow)3.505QIR (Microglass - Reverse Flow)0 to 35G1/23.5 bar
EPF1105QIVF3LG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.3.5Deck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline FilterUp to 450Housing: Iron/SteelFluorelastomerElectronic 4 LED, PNP, N.C.5 µmStandard, incl. Bypass0 to 35 l/min05QI (Microglass)5.005QI (Microglass)0 to 35G1/25.0 bar
EPF1105QIVT1KG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5Deck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline FilterUp to 450Housing: Iron/SteelFluorelastomerElectrical NO/NC5 µmStandard, incl. Bypass0 to 35 l/min05QI (Microglass)3.505QI (Microglass)0 to 35G1/23.5 bar
EPF1110QIBM3KG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5 barWheeled LoadersHydraulic Oil FiltersiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrileVisual10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)3.510QI (Microglass)0 to 40G1/23.5 barInline-40 to 100 °C
EPF1110QIBM3MG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barForwardersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)7.010QI (Microglass)0 to 40G1/27.0 bar
EPF1110QIBPKG081
Quote Required
TBD
ParkerMarineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorDeck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)3.510QI (Microglass)0 to 40G1/23.5 bar
EPF1110QIBPMG081
Quote Required
TBD
ParkerMiningHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorExcavatorsHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)7.010QI (Microglass)0 to 40G1/27.0 bar
EPF1110QIBPMG081EX
Quote Required
TBD
ParkerConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorWind turbinesHydraulic Oil FiltersiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrilePlugged with steel plug10 µmAtex0 to 40 l/min10QI (Microglass)7.010QI (Microglass)0 to 40G1/27.0 barInline-40 to 100 °C
EPF1110QIBT1KG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5 barForwardersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)3.510QI (Microglass)0 to 40G1/23.5 bar
EPF1110QIBT1MG081
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barWheeled LoadersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC10 µmStandard, incl. Bypass0 to 40 l/min10QI (Microglass)7.010QI (Microglass)0 to 40G1/27.0 bar
EPF1110QIBXKKIT1
Quote Required
TBD
ParkerOil and GasHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorHydraulic PressesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileNo indicator10 µmBowl + Element kit, incl. Bypass0 to 40 l/min10QI (Microglass)No filter head3.510QI (Microglass)0 to 40No filter head3.5 barManifold integrated-40 to 100 °C
EPF1110QIBXLKIT1
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorPower PacksHydraulic Oil FiltersiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrileNo indicator10 µmBowl + Element kit, incl. Bypass0 to 40 l/min10QI (Microglass)No filter head5.010QI (Microglass)0 to 40No filter head5.0 barManifold integrated-40 to 100 °C
EPF1110QIBXMKIT1
Quote Required
TBD
ParkerOil and GasHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorPower PacksHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileNo indicator10 µmBowl + Element kit, incl. Bypass0 to 40 l/min10QI (Microglass)No filter head7.010QI (Microglass)0 to 40No filter head7.0 barManifold integrated-40 to 100 °C
EPF1110QIHBM3MG082
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barHydraulic PressesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual10 µmNo bypass0 to 40 l/min10QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator10QIH (High Strength Microglass)0 to 40G1/2No Bypass with 5.0 bar indicator
EPF1110QIHBPMG082EX
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorWheeled LoadersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug10 µmAtex, no Bypass0 to 40 l/min10QIH (High Strenght Microglass)7.010QIH (High Strength Microglass)0 to 40G1/27.0 barInline-40 to 100 °C
EPF1110QIHBPXG082
Quote Required
TBD
ParkerOil and GasHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorWheeled LoadersHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug10 µmNo bypass0 to 40 l/min10QIH (High Strenght Microglass)No bypass / No indicator10QIH (High Strength Microglass)0 to 40G1/2No Bypass / No indicator
EPF1110QIHBT1MG082
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5Deck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline FilterUp to 450Housing: Iron/SteelNitrileElectrical NO/NC10 µmNo bypass0 to 40 l/min10QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator10QIH (High Strength Microglass)0 to 40G1/2No Bypass with 5.0 bar indicator
EPF1110QIHVXXKIT2
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorWind turbinesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelFluorelastomerNo indicator10 µmBowl + Element kit, no Bypass0 to 40 l/min10QIH (High Strenght Microglass)No filter headNo bypass / No indicator10QIH (High Strength Microglass)0 to 40No filter headNo Bypass / No indicatorManifold integrated-20 to 120 °C
EPF1110QIRBM3KG08RFV
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5 barDeck and Mobile CranesHydraulic Oil FiltersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual10 µmReverse flow valve incl. Bypass0 to 40 l/min10QIR (Microglass - Reverse Flow)3.510QIR (Microglass - Reverse Flow)0 to 40G1/23.5 bar