- Availability & Price
- Search SKU
Filter by attributes
- Controller Type
- Maximum Flow Rate
- Port Size
Filter by manufacturer
HDK Series High Pressure Compressed Air Dryer (up to 50 bar g)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker HDK 50 bar range of high pressure compressed air dryers are designed to dry compressed air and gaseous nitrogen at high pressure levels of up to 50 bar reliably and efficiently to multiple pressure dew point options of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F). HDK series dryers come equipped with integrated Parker pre- and after filtration and are capable of volume flows up to 1180 m³/h @ 50 bar g, 35°C (695 cfm @ 725 psi g, 95°F).
Typical applications for HDK series high pressure compressed air dryers are in power stations (i.e. start up of diesel generators) as well as marine applications (i.e. tank ventilation, rope tensioning on off-shore rigs, generator start up etc.).
Product Features
• Pressure dew point options available of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F)
• Volume flows up to 1180 m³/h @ 50 bar g, 35°C (695 cfm @ 725 psi g, 95°F)
• Pre- and after filters supplied as standard
Scope of Supply
• Ready to install high pressure adsorption dryer including dew point control and mounted pre-and after filter
• Optional equipment available mounted ex-works
Available Accessories
• Start-up device
• High pressure differential pressure gauges for the filters
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Typical applications for HDK series high pressure compressed air dryers are in power stations (i.e. start up of diesel generators) as well as marine applications (i.e. tank ventilation, rope tensioning on off-shore rigs, generator start up etc.).
Product Features
• Pressure dew point options available of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F)
• Volume flows up to 1180 m³/h @ 50 bar g, 35°C (695 cfm @ 725 psi g, 95°F)
• Pre- and after filters supplied as standard
Scope of Supply
• Ready to install high pressure adsorption dryer including dew point control and mounted pre-and after filter
• Optional equipment available mounted ex-works
Available Accessories
• Start-up device
• High pressure differential pressure gauges for the filters
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Division | Minimum Ambient Temperature | Connection Type | Width | Ingress Protection Rating | Minimum Operating Pressure | Brand | Maximum Operating Pressure | Compatible Prefilter | Depth | Product Type | Maximum Ambient Temperature | Height | Maximum Flow Rate | Compatible After Filter | Pressure Dew Point | Maximum Operating Temperature | Weight | Minimum Operating Temperature | Electrical Requirements | Specifications Met | Controller Type | Maximum Flow Rate | Port Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H120/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 786 mm | 65 | 58.02 psig | Zander | 50 barg | G7/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1489 mm | 141.26 CFM at 362.59 psig, PDP to 104°F | G7/50V | -13 to -97 °F | 122 °F | 113 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 240m³/h @ 50 bar g, 35°C | 1/2" | ||
| H120/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 786 mm | 65 | 4 barg | Zander | 725.19 psig | G7/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1489 mm | 141.26 CFM at 362.59 psig, PDP to 104°F | G7/50V | -70 °C | 122 °F | 113 kg | 77 °F | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 240m³/h @ 50 bar g, 35°C | 1/2" | ||
| H160/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 815 mm | 65 | 4 barg | Zander | 50 barg | G9/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1489 mm | 211.89 CFM at 362.59 psig, PDP to 104°F | G9/50V | -25.0 °C | 50 °C | 153 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 360m³/h @ 50 bar g, 35°C | 3/4" | ||
| H160/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 815 mm | 65 | 4 barg | Zander | 725.19 psig | G9/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1489 mm | 211.89 CFM at 362.59 psig, PDP to 104°F | G9/50V | -13 to -97 °F | 122 °F | 153 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 360m³/h @ 50 bar g, 35°C | 3/4" | ||
| H18/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 675 mm | 65 | 4 barg | Zander | 725.19 psig | G3/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 925 mm | 29.43 CFM at 362.59 psig, PDP to 104°F | G3/50V-15G | -13 to -97 °F | 122 °F | 65 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 50m³/h @ 50 bar g, 35°C | 1/2" | ||
| H18/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 675 mm | 65 | 58.02 psig | Zander | 50 barg | G3/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 925 mm | 29.43 CFM at 362.59 psig, PDP to 104°F | G3/50V-15G | -70 °C | 122 °F | 65 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 50m³/h @ 50 bar g, 35°C | 1/2" | ||
| H210/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 840 mm | 65 | 58.02 psig | Zander | 50 barg | G9/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1484 mm | 282.52 CFM at 362.59 psig, PDP to 104°F | G9/50V | -13 to -97 °F | 50 °C | 182 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 480m³/h @ 50 bar g, 35°C | 3/4" | ||
| H210/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 840 mm | 65 | 58.02 psig | Zander | 725.19 psig | G9/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1484 mm | 282.52 CFM at 362.59 psig, PDP to 104°F | G9/50V | -25.0 °C | 50 °C | 182 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 480m³/h @ 50 bar g, 35°C | 3/4" | ||
| H360/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 890 mm | 65 | 58.02 psig | Zander | 725.19 psig | G11/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1576 mm | 459.09 CFM at 362.59 psig, PDP to 104°F | G11/50V | -70 °C | 122 °F | 240 kg | 77 °F | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 780m³/h @ 50 bar g, 35°C | 3/4" | ||
| H360/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 890 mm | 65 | 4 barg | Zander | 50 barg | G11/50XP | 400 mm | High Pressure Adsorption | 50 °C | 1576 mm | 459.09 CFM at 362.59 psig, PDP to 104°F | G11/50V | -70 °C | 50 °C | 240 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 780m³/h @ 50 bar g, 35°C | 3/4" | ||
| H40/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 735 mm | 65 | 58.02 psig | Zander | 50 barg | G3/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 1190 mm | 58.86 CFM at 362.59 psig, PDP to 104°F | G3/50V-15G | -25.0 °C | 122 °F | 78 kg | 77 °F | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 100m³/h @ 50 bar g, 35°C | 1/2" | ||
| H40/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 735 mm | 65 | 4 barg | Zander | 50 barg | G3/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 1190 mm | 58.86 CFM at 362.59 psig, PDP to 104°F | G3/50V-15G | -70 °C | 50 °C | 78 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 100m³/h @ 50 bar g, 35°C | 1/2" | ||
| H550/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 945 mm | 65 | 58.02 psig | Zander | 725.19 psig | G12/50XP-25G | 400 mm | High Pressure Adsorption | 50 °C | 1576 mm | 694.53 CFM at 362.59 psig, PDP to 104°F | G12/50V-25G | -13 to -97 °F | 50 °C | 390 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 1180m³/h @ 50 bar g, 35°C | 3/4" | ||
| H550/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 945 mm | 65 | 4 barg | Zander | 50 barg | G12/50XP-25G | 400 mm | High Pressure Adsorption | 50 °C | 1576 mm | 694.53 CFM at 362.59 psig, PDP to 104°F | G12/50V-25G | -13 to -97 °F | 50 °C | 390 kg | 77 °F | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 1180m³/h @ 50 bar g, 35°C | 3/4" | ||
| H80/50D0-G230M | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 790 mm | 65 | 58.02 psig | Zander | 725.19 psig | G5/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 1290 mm | 117.72 CFM at 362.59 psig, PDP to 104°F | G5/50V-15G | -25.0 °C | 50 °C | 104 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic | 200m³/h @ 50 bar g, 35°C | 1/2" | ||
| H80/50D0-G230MT | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 1 °C | BSP-P | 790 mm | 65 | 58.02 psig | Zander | 725.19 psig | G5/50XP-15G | 400 mm | High Pressure Adsorption | 50 °C | 1290 mm | 117.72 CFM at 362.59 psig, PDP to 104°F | G5/50V-15G | -25.0 °C | 50 °C | 104 kg | 25 °C | 230V, 50-60Hz, others on request | PED, others on request | Multitronic with Dew Point Sensor | 200m³/h @ 50 bar g, 35°C | 1/2" |