The patent protected HDK-MT concept is unique in its compact design. HDK-MT combines a vibration resistant, torsion rigid dryer unit, made of high precision vessel pipes and valve blocks, with a pre-stressed filling of highly active desiccant beads.
HDK-MT dryers come mounted with GH series filters, incorporating tie-rod fixed filter elements, which provide almost no target for torsional forces and abrasion. This provides a safe, reliable, and robust operation under pressure variations and constant vibration, typical for discontinuous operation in high pressure ranges.
The choice of corrosion resistant materials, like the hard coated aluminium valve blocks, seamless vessels and stainless steel fittings make HDK-MT series dryers ideally suited for harsh environments.
Compact and robust in design HDK-MT dryers are ideally suited for installations in tight spaces, like compressor skids, as well as installations on ships, platforms, and in containers.
Features
• Dew-point control as standard
• Compact, unique patent protected design of the pressure envelope
• Pulsation and vibration resistant
• Corrosion resistant
• Small footprint
• Simple servicing
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...HDK-MT dryers come mounted with GH series filters, incorporating tie-rod fixed filter elements, which provide almost no target for torsional forces and abrasion. This provides a safe, reliable, and robust operation under pressure variations and constant vibration, typical for discontinuous operation in high pressure ranges.
The choice of corrosion resistant materials, like the hard coated aluminium valve blocks, seamless vessels and stainless steel fittings make HDK-MT series dryers ideally suited for harsh environments.
Compact and robust in design HDK-MT dryers are ideally suited for installations in tight spaces, like compressor skids, as well as installations on ships, platforms, and in containers.
Features
• Dew-point control as standard
• Compact, unique patent protected design of the pressure envelope
• Pulsation and vibration resistant
• Corrosion resistant
• Small footprint
• Simple servicing
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Minimum Operating Pressure | Minimum Operating Temperature | Division | Minimum Ambient Temperature | Compatible Prefilter | Specifications Met | Height | Electrical Requirements | Brand | Maximum Operating Pressure | Maximum Operating Temperature | Weight | Port Size | Ingress Protection Rating | Depth | Controller Type | Maximum Flow Rate | Width | Pressure Dew Point | Compatible After Filter | Product Type | Connection Type | Maximum Ambient Temperature | Maximum Flow Rate (m³/h) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H15/100D2-G230MT | Quote Required | TBD | 725.19 psig | 1 °C | Gas Separation and Filtration Division EMEA | 1 °C | GH7/100XP | PED 97/23/EC Fluid Group II, TR | 1050 mm | 230V, 50-60Hz, others on request | Zander | 1450 psig | 55 °C | 160 kg | 1/2 inch | 65 | 370 mm | Multitronic with Dew Point Sensor | 70.63 CFM at 1450 psig, PDP to 104°F | 700 mm | -40 °C | GH7/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 120 @ 100 bar(g) / PDP - 40° C | ||
| H20/100D2-G230MT | Quote Required | TBD | 50 barg | 1 °C | Gas Separation and Filtration Division EMEA | 1 °C | GH7/100XP | PED 97/23/EC Fluid Group II, TR | 1250 mm | 230V, 50-60Hz, others on request | Zander | 1450 psig | 131 °F | 180 kg | 1/2 inch | 65 | 370 mm | Multitronic with Dew Point Sensor | 105.94 | 700 mm | -40 °C | GH7/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 180 @ 100 bar(g) / PDP - 40° C | ||
| H25/100D2-G230MT | Quote Required | TBD | 50 barg | 33.8 °F | Gas Separation and Filtration Division EMEA | 1 °C | GH7/100XP | PED 97/23/EC Fluid Group II, TR | 1450 mm | 230V, 50-60Hz, others on request | Zander | 100 barg | 131 °F | 200 kg | 1/2 inch | 65 | 370 mm | Multitronic with Dew Point Sensor | 141.26 CFM at 1450 psig, PDP to 104°F | 700 mm | -13 to -104 °F | GH7/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 240 @ 100 bar(g) / PDP - 40° C | ||
| H30/100D2-G230MT | Quote Required | TBD | 50 barg | 1 °C | Gas Separation and Filtration Division EMEA | 1 °C | GH7/100XP | PED 97/23/EC Fluid Group II, TR | 1650 mm | 230V, 50-60Hz, others on request | Zander | 1450 psig | 55 °C | 220 kg | 1/2 inch | 65 | 370 mm | Multitronic with Dew Point Sensor | 176.57 CFM at 1450 psig, PDP to 104°F | 700 mm | -13 to -104 °F | GH7/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 300 @ 100 bar(g) / PDP - 40° C | ||
| H40/100D2-G230MT | Quote Required | TBD | 50 barg | 33.8 °F | Gas Separation and Filtration Division EMEA | 1 °C | GH9/100XP | PED 97/23/EC Fluid Group II, TR | 1650 mm | 230V, 50-60Hz, others on request | Zander | 100 barg | 131 °F | 240 kg | 3/4 inch | 65 | 370 mm | Multitronic with Dew Point Sensor | 253.43 CFM at 1450 psig, PDP to 104°F | 770 mm | -13 to -104 °F | GH9/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 400 @ 100 bar(g) / PDP - 40° C | ||
| H50/100D2-G230MT | Quote Required | TBD | 50 barg | 33.8 °F | Gas Separation and Filtration Division EMEA | 1 °C | GH9/100XP | PED 97/23/EC Fluid Group II, TR | 1850 mm | 230V, 50-60Hz, others on request | Zander | 100 barg | 131 °F | 260 kg | 3/4 inch | 65 | 450 mm | Multitronic with Dew Point Sensor | 306.06 CFM at 1450 psig, PDP to 104°F | 770 mm | -13 to -104 °F | GH9/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 520 @ 100 bar(g) / PDP - 40° C | ||
| H70/100D2-G230MT | Quote Required | TBD | 725.19 psig | 33.8 °F | Gas Separation and Filtration Division EMEA | 1 °C | GH9/100XP | PED 97/23/EC Fluid Group II, TR | 2075 mm | 230V, 50-60Hz, others on request | Zander | 100 barg | 55 °C | 280 kg | 3/4 inch | 65 | 450 mm | Multitronic with Dew Point Sensor | 382.58 CFM at 1450 psig, PDP to 104°F | 770 mm | -40 °C | GH9/100ZP/VV | High Pressure Adsorption | BSP-P DIN ISO 228 | 50 °C | 650 @ 100 bar(g) / PDP - 40° C |