• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate (m³/h)
More Filters...
Filter by manufacturer
Manufacturers

HDK-MT High Pressure Compressed Air Dryer (up to 100 bar g)

Picture for category HDK-MT High Pressure Compressed Air Dryer (up to 100 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The patent protected HDK-MT concept is unique in its compact design. HDK-MT combines a vibration resistant, torsion rigid dryer unit, made of high precision vessel pipes and valve blocks, with a pre-stressed filling of highly active desiccant beads.

HDK-MT dryers come mounted with GH series filters, incorporating tie-rod fixed filter elements, which provide almost no target for torsional forces and abrasion. This provides a safe, reliable, and robust operation under pressure variations and constant vibration, typical for discontinuous operation in high pressure ranges.

The choice of corrosion resistant materials, like the hard coated aluminium valve blocks, seamless vessels and stainless steel fittings make HDK-MT series dryers ideally suited for harsh environments.

Compact and robust in design HDK-MT dryers are ideally suited for installations in tight spaces, like compressor skids, as well as installations on ships, platforms, and in containers.

Features
• Dew-point control as standard

• Compact, unique patent protected design of the pressure envelope

• Pulsation and vibration resistant

• Corrosion resistant

• Small footprint

• Simple servicing

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMinimum Operating PressureMinimum Operating TemperatureDivisionMinimum Ambient TemperatureCompatible PrefilterSpecifications MetHeightElectrical RequirementsBrandMaximum Operating PressureMaximum Operating TemperatureWeightPort SizeIngress Protection RatingDepthController TypeMaximum Flow RateWidthPressure Dew PointCompatible After FilterProduct TypeConnection TypeMaximum Ambient TemperatureMaximum Flow Rate (m³/h)
H15/100D2-G230MT
Quote Required
TBD
725.19 psig1 °CGas Separation and Filtration Division EMEA1 °CGH7/100XPPED 97/23/EC Fluid Group II, TR1050 mm230V, 50-60Hz, others on requestZander1450 psig55 °C160 kg1/2 inch65370 mmMultitronic with Dew Point Sensor70.63 CFM at 1450 psig, PDP to 104°F700 mm-40 °CGH7/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C120 @ 100 bar(g) / PDP - 40° C
H20/100D2-G230MT
Quote Required
TBD
50 barg1 °CGas Separation and Filtration Division EMEA1 °CGH7/100XPPED 97/23/EC Fluid Group II, TR1250 mm230V, 50-60Hz, others on requestZander1450 psig131 °F180 kg1/2 inch65370 mmMultitronic with Dew Point Sensor105.94700 mm-40 °CGH7/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C180 @ 100 bar(g) / PDP - 40° C
H25/100D2-G230MT
Quote Required
TBD
50 barg33.8 °FGas Separation and Filtration Division EMEA1 °CGH7/100XPPED 97/23/EC Fluid Group II, TR1450 mm230V, 50-60Hz, others on requestZander100 barg131 °F200 kg1/2 inch65370 mmMultitronic with Dew Point Sensor141.26 CFM at 1450 psig, PDP to 104°F700 mm-13 to -104 °FGH7/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C240 @ 100 bar(g) / PDP - 40° C
H30/100D2-G230MT
Quote Required
TBD
50 barg1 °CGas Separation and Filtration Division EMEA1 °CGH7/100XPPED 97/23/EC Fluid Group II, TR1650 mm230V, 50-60Hz, others on requestZander1450 psig55 °C220 kg1/2 inch65370 mmMultitronic with Dew Point Sensor176.57 CFM at 1450 psig, PDP to 104°F700 mm-13 to -104 °FGH7/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C300 @ 100 bar(g) / PDP - 40° C
H40/100D2-G230MT
Quote Required
TBD
50 barg33.8 °FGas Separation and Filtration Division EMEA1 °CGH9/100XPPED 97/23/EC Fluid Group II, TR1650 mm230V, 50-60Hz, others on requestZander100 barg131 °F240 kg3/4 inch65370 mmMultitronic with Dew Point Sensor253.43 CFM at 1450 psig, PDP to 104°F770 mm-13 to -104 °FGH9/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C400 @ 100 bar(g) / PDP - 40° C
H50/100D2-G230MT
Quote Required
TBD
50 barg33.8 °FGas Separation and Filtration Division EMEA1 °CGH9/100XPPED 97/23/EC Fluid Group II, TR1850 mm230V, 50-60Hz, others on requestZander100 barg131 °F260 kg3/4 inch65450 mmMultitronic with Dew Point Sensor306.06 CFM at 1450 psig, PDP to 104°F770 mm-13 to -104 °FGH9/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C520 @ 100 bar(g) / PDP - 40° C
H70/100D2-G230MT
Quote Required
TBD
725.19 psig33.8 °FGas Separation and Filtration Division EMEA1 °CGH9/100XPPED 97/23/EC Fluid Group II, TR2075 mm230V, 50-60Hz, others on requestZander100 barg55 °C280 kg3/4 inch65450 mmMultitronic with Dew Point Sensor382.58 CFM at 1450 psig, PDP to 104°F770 mm-40 °CGH9/100ZP/VVHigh Pressure AdsorptionBSP-P DIN ISO 22850 °C650 @ 100 bar(g) / PDP - 40° C