Most industrial compressed air applications operate at pressures around 7, 10 or 13 bar g and purification equipment is typically designed around these operating pressures. There are however, applications that require higher operating pressures (which also leads to increased concentration of many contaminants).
The Parker GH50 Series Intermediate Pressure filter range is available in multiple filtration grades to cover all filtration requirements, including general purpose and high efficiency coalescing grades, general purpose and an oil vapour reduction grade.
Features
• Meets the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality
• Pleated filter element – Coalescing and Dry Particulate filter media is constructed to reduce air flow velocity and pressure loss whilst providing increased dirt holding capacity, and improved filtration efficiency
• Filter element is secured by tie-rod to ensure element is held in place, even with pressure pulsations commonly experienced with piston compressors
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...The Parker GH50 Series Intermediate Pressure filter range is available in multiple filtration grades to cover all filtration requirements, including general purpose and high efficiency coalescing grades, general purpose and an oil vapour reduction grade.
Features
• Meets the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality
• Pleated filter element – Coalescing and Dry Particulate filter media is constructed to reduce air flow velocity and pressure loss whilst providing increased dirt holding capacity, and improved filtration efficiency
• Filter element is secured by tie-rod to ensure element is held in place, even with pressure pulsations commonly experienced with piston compressors
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Connection Type | Specifications Met | Division | Weight | Width | Drain | Product Series | Product Type | Technology | Height | Element Change Interval | Materials of Construction | Brand | Operating Temperature | Industry | Operating Pressure | Application | Filter Efficiency Rating | Division | Compatible Element | Port Size | Filter Type | Maximum Flow Rate | Micron Rating |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| G11/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 10.9 lb | 5.1 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 450.0 mm | When oil vapour is detected | Die Cast Aluminium | Parker | 35 to 122 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 2020A | 1" | Oil Vapour Reduction | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | Not Applicable | ||
| G11/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 10.9 lb | 5.1 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 17.7 inch | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 20 to 50 barg | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 2020XP | 1" | High Efficiency Coalescing and Dry Particulate | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | Down to 0.01 micron | ||
| G11/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 4.9 kg | 130.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 450.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 20 to 50 barg | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 2020ZP | 1" | General Purpose Coalescing and Dry Particulate | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | Down to 1 micron | ||
| G12/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 5 kg | 5.1 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 20.7 inch | When oil vapour is detected | Die Cast Aluminium | Parker | 2 to 50 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 2030A | 1½" | Oil Vapour Reduction | 1175 m³/h @ 7 barg (692 cfm @ 102 psig) | Not Applicable | ||
| G12/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 11.1 lb | 5.1 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 525.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 2030XP | 1½" | High Efficiency Coalescing and Dry Particulate | 1175 m³/h @ 7 barg (692 cfm @ 102 psig) | Down to 0.01 micron | ||
| G12/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 11.1 lb | 130.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 525.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 2 to 80 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 2030ZP | 1½" | General Purpose Coalescing and Dry Particulate | 1175 m³/h @ 7 barg (692 cfm @ 102 psig) | Down to 1 micron | ||
| G13/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 14.6 lb | 130.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 755.0 mm | When oil vapour is detected | Die Cast Aluminium | Parker | 2 to 50 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 2050A | 1½" | Oil Vapour Reduction | 1750 m³/h @ 7 barg (1030 cfm @ 102 psig) | Not Applicable | ||
| G13/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 6.6 kg | 130.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 755.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 2050XP | 1½" | High Efficiency Coalescing and Dry Particulate | 1750 m³/h @ 7 barg (1030 cfm @ 102 psig) | Down to 0.01 micron | ||
| G13/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 6.6 kg | 130.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 29.7 inch | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 2050ZP | 1½" | General Purpose Coalescing and Dry Particulate | 1750 m³/h @ 7 barg (1030 cfm @ 102 psig) | Down to 1 micron | ||
| G14/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 19.7 lb | 6.5 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 28.9 inch | When oil vapour is detected | Die Cast Aluminium | Parker | 35 to 122 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 3050A | 2" | Oil Vapour Reduction | 2600 m³/h @ 7 barg (1530 cfm @ 102 psig) | Not Applicable | ||
| G14/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 19.7 lb | 6.5 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 735.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 3050XP | 2" | High Efficiency Coalescing and Dry Particulate | 2600 m³/h @ 7 barg (1530 cfm @ 102 psig) | Down to 0.01 micron | ||
| G14/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 19.7 lb | 6.5 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 735.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 2 to 80 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 3050ZP | 2" | General Purpose Coalescing and Dry Particulate | 2600 m³/h @ 7 barg (1530 cfm @ 102 psig) | Down to 1 micron | ||
| G2/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 0.8 kg | 2.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 200.0 mm | When oil vapour is detected | Die Cast Aluminium | Parker | 35 to 122 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 1030A | ¼" | Oil Vapour Reduction | 75 m³/h @ 7 barg (44 cfm @ 102 psig) | Not Applicable | ||
| G2/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 0.8 kg | 2.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 200.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 1030XP | ¼" | High Efficiency Coalescing and Dry Particulate | 75 m³/h @ 7 barg (44 cfm @ 102 psig) | Down to 0.01 micron | ||
| G2/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 1.7 lb | 2.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 7.9 inch | 12 months or 6000 hours | Die Cast Aluminium | Parker | 2 to 80 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 1030ZP | ¼" | General Purpose Coalescing and Dry Particulate | 75 m³/h @ 7 barg (44 cfm @ 102 psig) | Down to 1 micron | ||
| G3/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 2.7 lb | 3.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 9.6 inch | When oil vapour is detected | Die Cast Aluminium | Parker | 35 to 122 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 20 to 50 barg | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 1050A | ¼" | Oil Vapour Reduction | 125 m³/h @ 7 barg (74 cfm @ 102 psig) | Not Applicable | ||
| G3/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 2.7 lb | 3.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 245.0 mm | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 1050XP | ¼" | High Efficiency Coalescing and Dry Particulate | 125 m³/h @ 7 barg (74 cfm @ 102 psig) | Down to 0.01 micron | ||
| G3/50ZP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 2.7 lb | 3.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 9.6 inch | 12 months or 6000 hours | Die Cast Aluminium | Parker | 35 to 176 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | 99.925 % | Gas Separation and Filtration Division EMEA | 1050ZP | ¼" | General Purpose Coalescing and Dry Particulate | 125 m³/h @ 7 barg (74 cfm @ 102 psig) | Down to 1 micron | ||
| G5/50A | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 1.2 kg | 87.0 mm | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 245.0 mm | When oil vapour is detected | Die Cast Aluminium | Parker | 35 to 122 °F | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 290 to 725 psig | Compressed Air and Nitrogen Gas Applications | n/a | Gas Separation and Filtration Division EMEA | 1070A | ⅜" | Oil Vapour Reduction | 175 m³/h @ 7 barg (103 cfm @ 102 psig) | Not Applicable | ||
| G5/50XP | Quote Required | TBD | BSPP | PED 2014/68/EU Fluid Group. II. | Gas Separation and Filtration Division EMEA | 1.2 kg | 3.4 inch | Manual Drain | G50 Series | Compressed Air Filter | Filtration | 9.6 inch | 12 months or 6000 hours | Die Cast Aluminium | Parker | 2 to 80 °C | Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental | 20 to 50 barg | Compressed Air and Nitrogen Gas Applications | 99.9999 % | Gas Separation and Filtration Division EMEA | 1070XP | ⅜" | High Efficiency Coalescing and Dry Particulate | 175 m³/h @ 7 barg (103 cfm @ 102 psig) | Down to 0.01 micron |