*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate. These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.
A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.
Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.
Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all
operational information
*Optional equipment
Read More...A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.
Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.
Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all
operational information
*Optional equipment
| Action | Part No. | Availability | Partner Available | Price | Maximum Ambient Temperature | Maximum Operating Temperature | Maximum Operating Pressure | Brand | Minimum Ambient Temperature | Compatible Prefilter | Installed Condensate Drain Type | Maximum Flow Rate | Compatible After Filter | Purge Pressure Rate | Minimum Operating Pressure | Depth | Compatible Prefilter Element | Optional Accessories | Maximum Inlet Pressure Rating | Minimum Operating Temperature | Product Type | Height | Compatible After Filter Element | Division | Connection Type | Width | Weight | Pressure Dew Point (F) | Electrical Requirements | Maximum Flow Rate (cfm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TWP1001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC1000-C | Demand Solenoid Drain | 1699 m3/hour | JC1000-FH | 70 | 80 psi | 41 inch | JE-CC0800 | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 102 inch | JE-FC0800-HT | Industrial Gas Filtration and Generation Division | 3" Flg | 74 inch | 4195 lb | -40 | 460V/3Ph/60Hz | 1000 | ||
| TWP1201FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JLA1603-C | Demand Solenoid Drain | 2038 m3/hour | JLA1800-FH | 84 | 80 psi | 41 inch | (2) JAE3-C | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 113 inch | JAE4-FH | Industrial Gas Filtration and Generation Division | 3" Flg | 74 inch | 5215 lb | -40 | 460V/3Ph/60Hz | 1200 | ||
| TWP1501FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JLA1603-C | Demand Solenoid Drain | 2548 m3/hour | JLA1800-FH | 105 | 80 psi | 60 inch | (2) JAE3-C | Pre and After Filtration | 100 PSI | 50 °F | Heated | 113 inch | JAE4-FH | Industrial Gas Filtration and Generation Division | 3" Flg | 78 inch | 7765 lb | -40 | 460V/3Ph/60Hz | 1500 | ||
| TWP2001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | JLA2100-C | Demand Solenoid Drain | 3398 m3/hour | JLA2600-FH | 140 | 80 psi | 60 inch | (3) JAE3-C | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 110 inch | (2) JAE4-FH | Industrial Gas Filtration and Generation Division | 4" Flg | 78 inch | 8565 lb | -40 | 460V/3Ph/60Hz | 2000 | ||
| TWP201BY21NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0250-C | Timed Solenoid Drain | 340 m3/hour | JC0250-FH | 14 | 80 psi | 22 inch | JE-CC0350 | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 85 inch | JE-FC0350-HT | Industrial Gas Filtration and Generation Division | 1 1/2” NPT | 40 inch | 920 lb | -40 | 240V/1Ph/60Hz | 200 | ||
| TWP251BY21NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0250-C | Timed Solenoid Drain | 425 m3/hour | JC0250-FH | 17.5 | 80 psi | 22 inch | JE-CC0350 | Pre and After Filtration | 100 PSI | 50 °F | Heated | 85 inch | JE-FC0350-HT | Industrial Gas Filtration and Generation Division | 1 1/2" NPT | 40 inch | 1180 lb | -40 | 240V/1Ph/60Hz | 250 | ||
| TWP2601FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | JLA3200-C | Demand Solenoid Drain | 4417 m3/hour | JLA2600-FH | 182 | 80 psi | 60 inch | (4) JAE3-C | Pre and After Filtration | 100 PSI | 50 °F | Heated | 112 inch | (2) JAE4-FH | Industrial Gas Filtration and Generation Division | 4" Flg | 96 inch | 11562 lb | -40 | 460V/3Ph/60Hz | 2600 | ||
| TWP3001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | JLA3206-C | Demand Solenoid Drain | 5097 m3/hour | JLA3506-FH | 210 | 80 psi | 60 inch | (4) JAE3-C | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 112 inch | (3) JAE3-FH | Industrial Gas Filtration and Generation Division | 6" Flg | 96 inch | 12002 lb | -40 | 460V/3Ph/60Hz | 3000 | ||
| TWP301BY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0350-C | Timed Solenoid Drain | 510 m3/hour | JC0350-FH | 21 | 80 psi | 27 inch | JE-CC0350 | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 87 inch | JE-FC0350-HT | Industrial Gas Filtration and Generation Division | 1 1/2" NPT | 43 inch | 1370 lb | -40 | 460V/3Ph/60Hz | 300 | ||
| TWP4001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | Consult Factory | Demand Solenoid Drain | 6796 m3/hour | Consult Factory | 280 | 80 psi | Consult Factory | Consult Factory | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | Consult Factory inch | Consult Factory | Industrial Gas Filtration and Generation Division | 6" Flg | Consult Factory inch | n/a Contact us | -40 | 460V/3Ph/60Hz | 4000 | ||
| TWP401BY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0450-C | Timed Solenoid Drain | 680 m3/hour | JC0450-FH | 28 | 80 psi | 27 inch | JE-CC0450 | Pre and After Filtration | 100 PSI | 50 °F | Heated | 88 inch | JE-FC0450-HT | Industrial Gas Filtration and Generation Division | 2" NPT | 47 inch | 1400 lb | -40 | 460V/3Ph/60Hz | 400 | ||
| TWP5001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | Consult Factory | Demand Solenoid Drain | 8495 m3/hour | Consult Factory | 350 | 80 psi | Consult Factory | Consult Factory | Pre and After Filtration | 100 PSI | 50 °F | Heated | Consult Factory inch | Consult Factory | Industrial Gas Filtration and Generation Division | 6" Flg | Consult Factory inch | n/a Contact us | -40 | 460V/3Ph/60Hz | 5000 | ||
| TWP501BY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0625-C | Timed Solenoid Drain | 850 m3/hour | JC0625-FH | 35 | 80 psi | 27 inch | JE-CC0625 | Pre and After Filtration | 100 PSI | 50 °F | Heated | 89 inch | JE-FC0625-HT | Industrial Gas Filtration and Generation Division | 2" NPT | 50 inch | 2060 lb | -40 | 460V/3Ph/60Hz | 500 | ||
| TWP6001FY41NNN | Quote Required | TBD | 120 °F | 120 °F | 135 psi | Airtek | 40 °F | Consult Factory | Demand Solenoid Drain | 10194 m3/hour | Consult Factory | 420 | 80 psi | Consult Factory | Consult Factory | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | Consult Factory inch | Consult Factory | Industrial Gas Filtration and Generation Division | 6" Flg | Consult Factory inch | n/a Contact us | -40 | 460V/3Ph/60Hz | 6000 | ||
| TWP601BY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0625-C | Timed Solenoid Drain | 1019 m3/hour | JC0625-FH | 42 | 80 psi | 28 inch | JE-CC0625 | Pre and After Filtration | 100 PSI | 50 °F | Compressed Air – Desiccant | 92 inch | JE-FC0625-HT | Industrial Gas Filtration and Generation Division | 2" NPT | 52 inch | 2350 lb | -40 | 460V/3Ph/60Hz | 600 | ||
| TWP8001FY41NNN | Quote Required | TBD | 120 | 120 | 135 | Airtek | 40 | Consult Factory | Demand Solenoid Drain | 13592 | Consult Factory | 560 | 80 | Consult Factory | Consult Factory | Pre and After Filtration | 100 | 50 | Compressed Air – Desiccant | Consult Factory | Consult Factory | Industrial Gas Filtration and Generation Division | 8" Flg | Consult Factory | n/a Contact us | -40 | 460V/3Ph/60Hz | 8000 | ||
| TWP801BY41NNN | Quote Required | TBD | 120 °F | 120 °F | 150 psi | Airtek | 40 °F | JC0800-C | Timed Solenoid Drain | 1359 m3/hour | JC0800-FH | 56 | 80 psi | 35 inch | JE-CC0800 | Pre and After Filtration | 100 PSI | 50 °F | Heated | 93 inch | JE-FC0800-HT | Industrial Gas Filtration and Generation Division | 2" NPT | 63 inch | 3035 lb | -40 | 460V/3Ph/60Hz | 800 |