- Availability & Price
- Search SKU
Filter by attributes
- Configuration
- Flow Rate
- Maximum Inlet Pressure Rating
- Override Functionality
- Seal Material
Filter by manufacturer
Directional Control Proportional Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.
Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated
Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control
Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
| Action | Part No. | Availability | Partner Available | Price | UOM | Actuation Type | Seal Material | Body Material | Maximum Operating Pressure | Division | Maximum Kinematic Viscosity | Minimum Operating Temperature | Override Functionality | Maximum Inlet Pressure Rating | Operation Type | Installation Torque | Coil Nut Tightening Torque | Cavity Size | Maximum Operating Temperature | Frequency | Configuration | For Fluid Type | Valve Material | Operating Temperature | Filter Efficiency Rating | Coil Type | Response Time | Maximum Tank Pressure | Function | Leak Rate | Hysteresis | Flow Rate Accuracy | Variation of Opening Point | Power Consumption | Weight | Current | Flow Rate | Maximum Flow Rate | Seal Material | Configuration | Override Functionality | Maximum Inlet Pressure Rating | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GP0251LN | Quote Required | $240.25 | EA | Electrical | Nitrile | n/a | 5000 psi | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | n/a | 350 bar | Solenoid Operated | 22 lb-ft | 4.1 Nm | C08-4 | +121 °C | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 0.9, 1.4 Gal/min | 0.9, 1.4 Gal/min | Nitrile | Normally Closed | N/A | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | ||
| GP0251LV | Quote Required | TBD | Electrical | Fluorocarbon | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -26 °C | n/a | 5000 psi | Solenoid Operated | 22 lb-ft | 3 lb-ft | C08-4 | +400 °F | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.15 kg | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 3.4, 5.3 L/min | 3.4, 5.3 L/min | Fluorocarbon | Normally Closed | N/A | 5000 PSI, 350 BAR | 0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN | |||
| GP0251N | Quote Required | TBD | Electrical | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | n/a | 350 bar | Solenoid Operated | 22 lb-ft | 4.1 Nm | C08-4 | +250 °F | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 15, 17 L/min | 4, 4.5 Gal/min | Nitrile | Normally Closed | N/A | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | |||
| GP0251V | Quote Required | TBD | Electrical | Fluorocarbon | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -26 °C | n/a | 350 bar | Solenoid Operated | 22 lb-ft | 3 lb-ft | C08-4 | +400 °F | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 15, 17 L/min | 4, 4.5 Gal/min | Fluorocarbon | Normally Closed | N/A | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | |||
| GP02521N | Quote Required | TBD | Electrical, Manual | Nitrile | n/a | 5000 psi | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | Non-Detented | 5000 psi | Solenoid operated, Manually operated | 30 Nm | 3 lb-ft | C08-4 | +121 °C | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 4.5, 5.5 Gal/min | 4.5, 5.5 Gal/min | Nitrile | Normally Closed | Non-Detented | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP02521V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | Non-Detented | 5000 | Solenoid operated, Manually operated | 22 | 3 | C08-4 | +400 | 100-400 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 4.5, 5.5 | 4.5, 5.5 | Fluorocarbon | Normally Closed | Non-Detented | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP02522N | Quote Required | TBD | Electrical, Manual | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | Detented | 350 bar | Solenoid operated, Manually operated | 30 Nm | 3 lb-ft | C08-4 | +121 °C | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 17, 21 L/min | 4.5, 5.5 Gal/min | Nitrile | Normally Closed | Detented | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP02522V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 °F | Detented | 350 bar | Solenoid operated, Manually operated | 22 lb-ft | 3 lb-ft | C08-4 | +400 °F | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 17, 21 L/min | 17, 21 L/min | Fluorocarbon | Normally Closed | Detented | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP0252N | Quote Required | TBD | Electrical | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | n/a | 350 bar | Solenoid Operated | 22 lb-ft | 3 lb-ft | C08-4 | +121 °C | 100-400 Hz | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.15 kg | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 17, 21 L/min | 4.5, 5.5 Gal/min | Nitrile | Normally Closed | N/A | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP0252V | Quote Required | TBD | Electrical | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | n/a | 5000 | Solenoid Operated | 22 | 3 | C08-4 | +400 | 100-400 | Normally Closed | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 4.5, 5.5 | 4.5, 5.5 | Fluorocarbon | Normally Closed | N/A | 5000 PSI, 350 BAR | 4.5, 5.5 GAL/MIN, 17, 21 L/MIN | |||
| GP02531V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -26 °C | Non-Detented | 5000 psi | Solenoid operated, Manually operated | 30 Nm | 3 lb-ft | C08-4 | +400 °F | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -26 to +204 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.15 kg | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 2.7, 4 Gal/min | 10, 15 L/min | Fluorocarbon | Floating Center | Non-Detented | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | |||
| GP02532N | Quote Required | TBD | Electrical, Manual | Nitrile | n/a | 5000 psi | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | Detented | 350 bar | Solenoid operated, Manually operated | 22 lb-ft | 3 lb-ft | C08-4 | +250 °F | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.15 kg | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 10, 15 L/min | 10, 15 L/min | Nitrile | Floating Center | Detented | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | |||
| GP02532V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | Detented | 5000 | Solenoid operated, Manually operated | 22 | 3 | C08-4 | +400 | 100-400 | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 2.7, 4 | 2.7, 4 | Fluorocarbon | Floating Center | Detented | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN | |||
| GP0253L1N | Quote Required | $286.25 | EA | Electrical, Manual | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | Non-Detented | 5000 psi | Solenoid operated, Manually operated | 22 lb-ft | 3 lb-ft | C08-4 | +121 °C | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -30 to +250 °F | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 4, 5.3 L/min | 4, 5.3 L/min | Nitrile | Floating Center | Non-Detented | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | ||
| GP0253L1V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | Non-Detented | 5000 | Solenoid operated, Manually operated | 22 | 3 | C08-4 | +400 | 100-400 | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 1, 1.4 | 1, 1.4 | Fluorocarbon | Floating Center | Non-Detented | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | |||
| GP0253L2N | Quote Required | TBD | Electrical, Manual | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | Detented | 350 bar | Solenoid operated, Manually operated | 30 Nm | 4.1 Nm | C08-4 | +250 °F | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 1, 1.4 Gal/min | 4, 5.3 L/min | Nitrile | Floating Center | Detented | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | |||
| GP0253L2V | Quote Required | TBD | Electrical, Manual | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | Detented | 5000 | Solenoid operated, Manually operated | 22 | 3 | C08-4 | +400 | 100-400 | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 1, 1.4 | 1, 1.4 | Fluorocarbon | Floating Center | Detented | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | |||
| GP0253LN | Quote Required | $240.25 | EA | Electrical | Nitrile | n/a | 5000 psi | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -34 °C | n/a | 5000 psi | Solenoid Operated | 22 lb-ft | 4.1 Nm | C08-4 | +250 °F | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 3000 psi | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.15 kg | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 1, 1.4 Gal/min | 4, 5.3 L/min | Nitrile | Floating Center | N/A | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | ||
| GP0253LV | Quote Required | TBD | Electrical | Fluorocarbon | n/a | 5000 | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -15 | n/a | 5000 | Solenoid Operated | 22 | 3 | C08-4 | +400 | 100-400 | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -15 to +400 | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 | 3000 | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 | 0.34 | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC | 1, 1.4 | 1, 1.4 | Fluorocarbon | Floating Center | N/A | 5000 PSI, 350 BAR | 1, 1.4 GAL/MIN, 4, 5.3 L/MIN | |||
| GP0253N | Quote Required | TBD | Electrical | Nitrile | n/a | 350 bar | Hydraulic Systems Division | 45-2000 SSU (6 to 420 cSt) | -30 °F | n/a | 350 bar | Solenoid Operated | 30 Nm | 4.1 Nm | C08-4 | +121 °C | 100-400 Hz | Floating Center | Mineral-based or synthetic hydraulic fluids | All parts steel. All operating parts hardened steel | -34 to +121 °C | ISO 4406 18/16/13, SAE Class 4 | 1/2" Super Coil | 50 ms | 210 bar | Proportional Directional Control | 10 @ 3000 PSI (210 BAR) cm3/min | Less than 6% | +/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator | 25% - 30% of Input Signal | 14, 19 W | 0.34 lb | 1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A | 2.7, 4 Gal/min | 10, 15 L/min | Nitrile | Floating Center | N/A | 5000 PSI, 350 BAR | 2.7, 4 GAL/MIN, 10, 15 L/MIN |