• Availability & Price
  • Search SKU
Filter by attributes
  • Adjustment Mechanism
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Pressure Control Range
  • Seal Material
  • Sealed Pilot Included
More Filters...
Filter by manufacturer
Manufacturers

Direct Acting Sequence Valve

Picture for category Direct Acting Sequence Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of direct acting sequence valves are fast acting and designed for sequenced applications with pressures up to 420 bar (6000 psi) and flows up to 56 lpm (15 gpm) in a variety of sizes. The selection of pressure adjustment styles and piloted or vented controls makes these valves an ideal solution for controlling multiple circuit sections that operate at different pressure settings. Normally-open and normally-closed valves are available in either 2 position 2-way or 2 position 3-way configurations. These direct acting sequence valves can be used within clamping circuits or high/low system applications within several industrial and mobile markets.



Markets:

• Agriculture

• Construction

• Material Handling

• Miscellaneous Industrial

• Miscellaneous Manufacturing

• Miscellaneous Mobile



Features & Benefits:

• Fast response

• Internal mechanical stops limiting spool travel

• Hardened, precision ground parts for durability

• All external parts zinc plated

• Adjustable, fixed, or tamper resistant adjustments available



Applications:

• Dump circuits

• High/low systems

• Sequencing applications



Additional Technical Insight:

Direct acting sequence valves are spool-type devices that allow multiple functions to operate in sequence without the need for solenoid valves, limit switches, or complex control systems.  Parker’s B02, B04, and SV10 sequence valves provide design options for 2-position 2-way or 2-position 3-way sequencing with pilot signals and drains provided internally or externally.  Externally drained versions are not sensitive to downstream pressure if they are drained to the tank. One or more sequence valves can be used in a circuit to allow multiple functions to operate in a specific order based on pressure.  Normally closed and normally open versions are available to allow for design flexibility.



Parker’s B04H4, B04J4, and SV104 series of direct acting sequence valves are Externally Piloted and Externally Drained.  The Normally Closed B04H4 is a 2-position 2-way valve that blocks flow in both directions until an external pilot supply pressure overcomes the sequencing setting.  B04J4 and SV104 are Normally Open 2-position 2-way valves that allow bi-directional flow until the external pilot supply reaches the sequence setting.  All three valves are insensitive to back pressure when their drain line is connected to tank.



Parker’s B04F3, B04G3, B04K4, and SV105 series of direct acting sequence valves are Externally Piloted and Internally Drained.  The Normally Closed B04F3 and SV105 are 2-postion 2-way valves that prevent flow from passing from port 3 to 2 until an external pilot supply pressure overcomes the sequencing setting.  Once the sequence pressure is reached the valve will open allowing flow from port 3 to 2.  B04G3 is a 2-position 2-way Normally Open valve that allows flow from port 2 to 3 until the external pilot pressure reaches the sequence pressure blocking flow from 2 to 3.  B04K4 is a 2-position 3-way normally open valve that allows bi-directional flow between ports 2 and 3 until the sequence pressure is met.  Once the pilot pressure exceeds the set pressure, port 2 is blocked and flow is allowed from port 3 to port 4.  The internal drain causes downstream pressure to be additive to the valves pressure setting, therefore it is most common for the downstream port to be connected to tank.



Parker’s B02E3F and B04E3 direct acting 2-position 3-way sequence valves are Internally Piloted and Internally Drained.  Flow from port 2 to 1 is normally open until the pressure at port 1 exceeds the valves setting which closes port 3 and allows flow from port 1 to port 2.



Parker’s SV103 direct acting 2-position 3-way sequence valve is Internally Piloted and Externally Drained.  Flow from port 1 to 2 is Normally Closed until the pressure at port 1 exceeds the sequence setting which allows flow from port 1 to 2.  Port 3 is a dedicated spring chamber vent which makes the valve insensitive to downstream pressure at port 2.



Please contact us if you have a sequencing application that requires higher flow rates.  Pilot Operated Sequence Valves are capable of flows up to 42 GPM.  Higher flows up to 130 GPM can be achieved with the use of logic elements and small pilot valves.

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialMinimum Operating TemperatureFor Fluid TypePilot LocationValve MaterialFilter Efficiency RatingMaximum Kinematic ViscosityMaximum Operating TemperatureWeightMaximum Operating PressureMaximum Flow RateMounting TypeActuation TypeDivisionOperation TypeAdjustment MechanismMaximum Tank PressureOperating TemperatureMaximum Inlet Pressure RatingFunctionDrain OptionConfigurationInstallation TorqueSealed Pilot IncludedPressure Control RangeMaximum Pressure SettingStandard Setting PressurePressure Control SensitivityCavity SizeFlow RateLeak RateSeal MaterialAdjustment MechanismMaximum Inlet Pressure RatingSealed Pilot IncludedPressure Control RangeFlow Rate
B04K4GTN
Quote Required
TBD
Nitrilen/a-30Mineral-based Hydraulic FluidsExternalSteel (all parts)ISO 4406 18/16/1345-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 2506000Direct Acting SequenceInternalSelector50No30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileTamper Resistant6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GTNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 2506000Direct Acting SequenceInternalSelector50Yes30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileTamper Resistant6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GTV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 4006000Direct Acting SequenceInternalSelector50No30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonTamper Resistant6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GTVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 4006000Direct Acting SequenceInternalSelector50Yes30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonTamper Resistant6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GWN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 2506000Direct Acting SequenceInternalSelector50No30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileKnob6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GWNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 2506000Direct Acting SequenceInternalSelector50Yes30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileKnob6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GWV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 4006000Direct Acting SequenceInternalSelector50No30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonKnob6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GWVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 4006000Direct Acting SequenceInternalSelector50Yes30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonKnob6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GZN
Quote Required
$0.01
EANitrilen/a-30 °FSynthetic Hydraulic FluidsExternalHardened Steel (all operating parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C0.33 kg420 bar11 Gal/minScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew420 bar-34 to 121 °C420 barDirect Acting SequenceInternalSelector50 NmNo2 to 166 bar2400 psi80 bar17 bar Per TurnC10-411 Gal/min40 cm3/min @ 1450 Psi (100 bar)NitrileScrew6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GZNS
Quote Required
TBD
Nitrilen/a-34 °CMineral-based Hydraulic FluidsExternalHardened Steel (all operating parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C0.73 lb6000 psi42 L/minScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000 psi-30 to 250 °F420 barDirect Acting SequenceInternalSelector50 NmYes30 to 2400 psi166 bar1160 psi248 psi Per TurnC10-442 L/min40 cm3/min @ 1450 Psi (100 bar)NitrileScrew6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GZV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 4006000Direct Acting SequenceInternalSelector50No30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonScrew6000 PSI, 420 BARNo30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4GZVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 4006000Direct Acting SequenceInternalSelector50Yes30 to 240024001160248 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonScrew6000 PSI, 420 BARYes30-2400 PSI, 2-166 BAR11 GAL/MIN, 42 L/MIN
B04K4JTN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 2506000Direct Acting SequenceInternalSelector50No580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileTamper Resistant6000 PSI, 420 BARNo580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JTNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 2506000Direct Acting SequenceInternalSelector50Yes580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileTamper Resistant6000 PSI, 420 BARYes580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JTV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 4006000Direct Acting SequenceInternalSelector50No580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonTamper Resistant6000 PSI, 420 BARNo580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JTVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 4006000Direct Acting SequenceInternalSelector50Yes580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonTamper Resistant6000 PSI, 420 BARYes580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JWN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 2506000Direct Acting SequenceInternalSelector50No580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileKnob6000 PSI, 420 BARNo580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JWNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)2500.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 2506000Direct Acting SequenceInternalSelector50Yes580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)NitrileKnob6000 PSI, 420 BARYes580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JWV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 4006000Direct Acting SequenceInternalSelector50No580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonKnob6000 PSI, 420 BARNo580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN
B04K4JWVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)4000.73600011Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 4006000Direct Acting SequenceInternalSelector50Yes580 to 350035001750406 psi Per TurnC10-41140 cm3/min @ 1450 Psi (100 bar)FluorocarbonKnob6000 PSI, 420 BARYes580-3500 PSI, 40-240 BAR11 GAL/MIN, 42 L/MIN