Products specifications
Attribute nameAttribute value
Seal MaterialNitrileBody Materialn/a
Maximum Operating Pressure6000 psiFor Fluid TypeMineral-based Hydraulic Fluids
Pilot LocationExternalFilter Efficiency RatingSAE Class 4
Maximum Kinematic Viscosity45-2000 SSU (6 to 420 cSt)Maximum Operating Temperature121 °C
Minimum Operating Temperature-34 °CMounting TypeScrew-in Cartridge
Actuation TypePressure SensingDivisionMobile Hydraulic Systems Division Europe
Operation TypeAutomaticValve MaterialHardened Steel (all operating parts)
Adjustment MechanismScrewMaximum Tank Pressure6000 psi
Operating Temperature-30 to 250 °FMaximum Inlet Pressure Rating420 bar
Installation Torque50 NmFunctionDirect Acting Sequence
Drain OptionInternalConfigurationSelector
Sealed Pilot IncludedYesPressure Control Range30 to 2400 psi
Maximum Pressure Setting166 barStandard Setting Pressure1160 psi
Pressure Control Sensitivity248 psi Per TurnWeight0.73 lb
Cavity SizeC10-4Flow Rate42 L/min
Leak Rate40 cm3/min @ 1450 Psi (100 bar)Maximum Flow Rate42 L/min
Seal MaterialNitrileAdjustment MechanismScrew
Maximum Inlet Pressure Rating6000 PSI, 420 BARSealed Pilot IncludedYes
Pressure Control Range30-2400 PSI, 2-166 BARFlow Rate11 GAL/MIN, 42 L/MIN