• Availability & Price
  • Search SKU
Filter by attributes
  • Connection Type
  • Flow Rate
  • ISO Grade
  • Port Size
  • Pressure Dew Point
  • Pump Type
More Filters...
Filter by manufacturer
Manufacturers

CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

Picture for category CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionDivisionIngress Protection RatingOperating TemperatureNoise LevelAmbient TemperatureDepthWidthHeightWeightIndustryApplicationProduct TypeProduct StyleProduct SeriesOperating PressureSpecifications MetFilter IncludedPower Supply VoltageConnection TypePort SizeISO GradeFlow RatePressure Dew PointPump Type
CDASLE120-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA131.0 °F Maximum550.0 mm856.0 mm1647.0 mm782 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.2.2 or Class 2.3.2765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE120-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)355 Kg<br/>(782 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.2.2 or Class 2.3.2765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE120-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch856.0 mm64.8 inch782 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.1.2536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE120-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)355 Kg<br/>(782 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.1.2536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE130-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm40.3 inch1892.0 mm992 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.2.2 or Class 2.3.21020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE130-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)450 Kg<br/>(992 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.2.2 or Class 2.3.21020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE130-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum550.0 mm1025.0 mm74.5 inch450 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX460.0 VAC (±10%) three-phase, 60Hz (Option)BSPP2½"Class 2.1.2714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE130-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)450 Kg<br/>(992 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.1.2714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-170 (Order Separately)
CDASLE140-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA131.0 °F Maximum550.0 mm47.0 inch74.5 inch1197 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX460.0 VAC (±10%) three-phase, 60Hz (Option)BSPP2½"Class 2.2.2 or Class 2.3.21275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE140-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)543 Kg<br/>(1197 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.2.2 or Class 2.3.21275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE140-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum21.7 inch47.0 inch74.5 inch543 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.1.2893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE140-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)543 Kg<br/>(1197 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.1.2893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE150-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch1363.0 mm74.5 inch637 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.2.2 or Class 2.3.21530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE150-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.2.2 or Class 2.3.21530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE150-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch1363.0 mm1892.0 mm637 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2½"Class 2.1.21071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)
CDASLE150-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2½"Class 2.1.21071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-130 (Order Separately)
CDASLE160-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm1532.0 mm1892.0 mm731 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX460.0 VAC (±10%) three-phase, 60Hz (Option)BSPP3"Class 2.2.2 or Class 2.3.21785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE160-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT3"Class 2.2.2 or Class 2.3.21785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)
CDASLE160-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA131.0 °F Maximum21.7 inch60.3 inch1892.0 mm1611 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX460.0 VAC (±10%) three-phase, 60Hz (Option)BSPP3"Class 2.1.21250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-160 (Order Separately)
CDASLE160-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT3"Class 2.1.21250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)