CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

Picture for category CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionDivisionIngress Protection RatingOperating TemperatureNoise LevelAmbient TemperatureDepthWidthHeightWeightIndustryApplicationProduct TypeProduct StyleProduct SeriesOperating PressureSpecifications MetFilter IncludedPower Supply VoltageConnection TypePort SizeISO GradeFlow RatePressure Dew PointPump Type
CDASHL150-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm53.6 inch1892.0 mm637 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"Class 2.2.2 or Class 2.3.21530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL150-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"Class 2.2.2 or Class 2.3.21530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL150-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum550.0 mm1363.0 mm74.5 inch1404 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"Class 2.1.21071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL150-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"Class 2.1.21071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL160-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum21.7 inch1532.0 mm1892.0 mm731 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP3"Class 2.2.2 or Class 2.3.21785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL160-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100-240V (+/-10%) 1ph 50/60HzNPT3"Class 2.2.2 or Class 2.3.21785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL160-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA131.0 °F Maximum21.7 inch60.3 inch1892.0 mm731 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP3"Class 2.1.21250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL160-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100-240V (+/-10%) 1ph 50/60HzNPT3"Class 2.1.21250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL170-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum550.0 mm67 inch1892.0 mm825 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP3"Class 2.2.2 or Class 2.3.22040 m³/h/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL170-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1701 mm<br/>(67.0inch)1892 mm<br/>(74.5 inch)825 Kg<br/>(1818 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100-240V (+/-10%) 1ph 50/60HzNPT3"Class 2.2.2 or Class 2.3.22040 m³/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL170-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum550.0 mm67 inch74.5 inch825 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP3"Class 2.1.21428 m³/h/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL170-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1701 mm<br/>(67.0inch)1892 mm<br/>(74.5 inch)825 Kg<br/>(1818 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX100-240V (+/-10%) 1ph 50/60HzNPT3"Class 2.1.21428 m³/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASLE100-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum550.0 mm687.0 mm64.8 inch518 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX460.0 VAC (±10%) three-phase, 60Hz (Option)BSPP2"Class 2.2.2 or Class 2.3.2408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE100-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)235 Kg<br/>(518 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2"Class 2.2.2 or Class 2.3.2408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE100-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum21.7 inch27 inch64.8 inch518 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2"Class 2.1.2286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-100 (Order Separately)
CDASLE100-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)235 Kg<br/>(518 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2"Class 2.1.2286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE110-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum21.7 inch856.0 mm1892.0 mm696 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2"Class 2.2.2 or Class 2.3.2612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE110-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)316 Kg<br/>(696 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2"Class 2.2.2 or Class 2.3.2612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-120 (Order Separately)
CDASLE110-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum550.0 mm856.0 mm1892.0 mm316 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400.0 VAC (±10%) three-phase, 50Hz (Standard)BSPP2"Class 2.1.2428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-110 (Order Separately)
CDASLE110-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)316 Kg<br/>(696 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationVacuum Assisted Heatless RegenerationCDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)NPT2"Class 2.1.2428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-130 (Order Separately)