Parker's CDAS HL Clean Dry Air Systems provide clean, dry compressed air in accordance with all editions of ISO8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of -70°C, -40°C or -20°C with flow rates up to 300 m³/hr (177 cfm) @ 7 barg (102 psi g).

Clean, dry air improves production efficiency and reduces maintenance costs and downtime. Many products claim to provide this, however only CDAS HL Clean Dry Air Systems provide the highest levels of dry compressed air with validated performance.

Features
• Energy saving dewpoint dependant switching included as standard*
• 4 Stages of purification
• Treatment of 7 contaminants (9 with optional WS)
• 3rd Party validated performance
• Pre/post filtration included
• ATEX option available, for use in potentially explosive atmospheres
• Corrosion protected
• Full bore internal flow paths

*Not available for ATEX models

Benefits
• High quality compressed air to ISO8573-1 classifications
• -40°C / -70°C PDP also controls microbiological growth
• Improves production efficiency and reduces maintenance costs and downtime
• Dry air means zero corrosion
• Easy and flexible installation

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMBrandTechnologyDivisionDivisionDepthOperating TemperatureOperating PressureSpecifications MetApplicationNoise LevelProduct TypeAmbient TemperatureIngress Protection RatingWidthHeightWeightProduct SeriesIndustryProduct StyleConnection TypePort SizeFlow RateISO GradePressure Dew PointATEX Specifications MetElectrical Requirements
CDASHL050-40G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA19 inch5 to 50 °C4 to 16 bargPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.0 mm1133.0 mm76 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL050-40G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL050-40G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.0 mm41 to 122 °F58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only559.0 mm45 inch168 lbCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL050-40N16AE
Quote Required
$8,691.62
EAParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.0 mm5 to 50 °C58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer131.0IP55 Indoor Use Only559.0 mm1133.0 mm76 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL050-40N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL050-40N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL050-70G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA19 inch41 to 122 °F58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.0 mm45 inch76 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL050-70G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC
CDASHL050-70G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL050-70N16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA19 inch5 to 50 °C58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0IP55 Indoor Use Only559.0 mm45 inch168 lbCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL050-70N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC
CDASHL050-70N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only559.01133.076CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch55 m³/h @ 7 barg (32 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL055-40G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.0 mm41 to 122 °F4 to 16 bargPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only559.0 mm1313.0 mm84 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL055-40G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01313.084CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL055-40G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA19 inch5 to 50 °C58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0IP55 Indoor Use Only559.0 mm1133.0 mm185.0 lbCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL055-40N16AE
Quote Required
$13,834.80
EAParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.0 mm5 to 50 °C58 to 232 psigPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0IP55 Indoor Use Only559.0 mm52 inch84 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL055-40N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01313.084CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL055-40N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01133.084CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessNPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL055-70G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.0 mm5 to 50 °C4 to 16 bargPED 2014/68/EU Fluid Group IICompressed Air Applications< 75 dBACompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only22 inch1313.0 mm84 kgCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL055-70G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA490.05 to 504 to 16PED 2014/68/EU Fluid Group IICompressed Air Applications< 75Compressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only559.01313.084CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatlessBSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC