Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

Picture for category Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.
Parker Airtek TWB Series Blower Purge Desiccant Air Dryers will effectively remove these contaminants.  The traditional adsorption principle used in this design is simple, robust and flexible using compressed air for regeneration therefore eliminating any need for an outside energy supply.
Continuous drying is accomplished by the operation of two desiccant towers.  

Compressed air is dried through one tower while the other desiccant tower is being regenerated.  The regeneration heating cycle of the desiccant is accomplished using a hot air flow delivered by an atmospheric blower and external electric heater (other means of heating are optional).  The regeneration cooling cycle is performed using a small flow of dry compressed air taken from the blower purge dryer outlet to ensure dewpoint performance. High levels of reliability are achieved by the use of proven engineering technology and components.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all operational information
*Optional equipment
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceHeightBrandConnection TypePurge Pressure RateCompatible After Filter ElementDivisionWidthMaximum Operating TemperatureProduct TypeMaximum Ambient TemperatureCompatible PrefilterMaximum Operating PressureInstalled Condensate Drain TypeMinimum Ambient TemperatureMaximum Flow RateOptional AccessoriesMaximum Inlet Pressure RatingMinimum Operating TemperatureCompatible After FilterWeightMinimum Operating PressureCompatible Prefilter ElementDepthMaximum Flow Rate (cfm)Pressure Dew Point (F)Electrical Requirements
TWB1001FY41NNN
Quote Required
TBD
102 inchAirtek3" Flg0JE-FC0800-HTIndustrial Gas Filtration and Generation Division74 inch120 °FBlower Purge120 °FJC1000-C150 psiDemand Solenoid Drain40 °F1699 m3/hourPre and After Filtration100 PSI50 °FJC1000-FH5700 lb80 psiJE-CC080041 inch1000-40460V/3Ph/60Hz
TWB1201FY41NNN
Quote Required
TBD
113 inchAirtek3" Flg0JAE4-FHIndustrial Gas Filtration and Generation Division74 inch120 °FCompressed Air – Desiccant120 °FJLA1603-C150 psiDemand Solenoid Drain40 °F2038 m3/hourPre and After Filtration100 PSI50 °FJLA1800-FH6300 lb80 psiJAE4-C41 inch1200-40460V/3Ph/60Hz
TWB1501FY41NNN
Quote Required
TBD
113 inchAirtek3" Flg0JAE4-FHIndustrial Gas Filtration and Generation Division78 inch120 °FCompressed Air – Desiccant120 °FJLA1603-C150 psiDemand Solenoid Drain40 °F2548 m3/hourPre and After Filtration100 PSI50 °FJLA1800-FH7165 lb80 psi(2) JAE3-C60 inch1500-40460V/3Ph/60Hz
TWB2001FY41NNN
Quote Required
TBD
112 inchAirtek4" Flg0(2) JAE3-FHIndustrial Gas Filtration and Generation Division114 inch120 °FCompressed Air – Desiccant120 °FJLA2100-C135 psiDemand Solenoid Drain40 °F3398 m3/hourPre and After Filtration100 PSI50 °FJLA2600-FH9850 lb80 psi(3) JAE3-C66 inch2000-40460V/3Ph/60Hz
TWB201BY41NNN
Quote Required
TBD
85 inchAirtek1 1/2” NPT0JE-FC0350-HTIndustrial Gas Filtration and Generation Division56 inch120 °FBlower Purge120 °FJC0250-C150 psiTimes Solenoid Drain50 °F340 m3/hourPre and After Filtration100 PSI50 °FJC0250-FH1500 lb80 psiJE-CC035039 inch200-40460V/3Ph/60Hz
TWB2601FY41NNN
Quote Required
TBD
112 inchAirtek4" Flg0(2) JAE3-FHIndustrial Gas Filtration and Generation Division132 inch120 °FCompressed Air – Desiccant120 °FJLA3200-C135 psiDemand Solenoid Drain40 °F4417 m3/hourPre and After Filtration100 PSI50 °FJLA2600-FH12210 lb80 psi(4) JAE3-C72 inch2600-40460V/3Ph/60Hz
TWB3001FY41NNN
Quote Required
TBD
112 inchAirtek6" Flg0(3) JAE3-FHIndustrial Gas Filtration and Generation Division132 inch120 °FBlower Purge120 °FJLA3206-C135 psiDemand Solenoid Drain40 °F5097 m3/hourPre and After Filtration100 PSI50 °FJLA3506-FH12650 lb80 psi(4) JAE3-C72 inch3000-40460V/3Ph/60Hz
TWB301BY41NNN
Quote Required
TBD
87 inchAirtek1 1/2" NPT0JE-FC0350-HTIndustrial Gas Filtration and Generation Division43 inch120 °FBlower Purge120 °FJC0350-C150 psiTimes Solenoid Drain50 °F510 m3/hourPre and After Filtration100 PSI50 °FJC0350-FH1900 lb80 psiJE-CC035027 inch300-40460V/3Ph/60Hz
TWB4001FY41NNN
Quote Required
TBD
114 inchAirtek6" Flg0(4) JAE3-FHIndustrial Gas Filtration and Generation Division168 inch120 °FCompressed Air – Desiccant120 °FJLA4500-C135 psiDemand Solenoid Drain40 °F6796 m3/hourPre and After Filtration100 PSI50 °FJLA5306-FH18910 lb80 psi(6) JAE3-C84 inch4000-40460V/3Ph/60Hz
TWB401BY41NNN
Quote Required
TBD
88 inchAirtek2" NPT0JE-FC0450-HTIndustrial Gas Filtration and Generation Division47 inch120 °FBlower Purge120 °FJC0450-C150 psiTimes Solenoid Drain40 °F680 m3/hourPre and After Filtration100 PSI50 °FJC0450-FH2180 lb80 psiJE-CC045027 inch400-40460V/3Ph/60Hz
TWB5001FY41NNN
Quote Required
TBD
114 inchAirtek6" Flg0(4) JAE3-FHIndustrial Gas Filtration and Generation Division156 inch120 °FCompressed Air – Desiccant120 °FJLA5000-C135 psiDemand Solenoid Drain40 °F8495 m3/hourPre and After Filtration100 PSI50 °FJLA5306-FH21590 lb80 psi(7) JAE3-C92 inch5000-40460V/3Ph/60Hz
TWB501BY41NNN
Quote Required
TBD
89 inchAirtek2" NPT0JE-FC0625-HTIndustrial Gas Filtration and Generation Division50 inch120 °FCompressed Air – Desiccant120 °FJC0625-C150 psiTimes Solenoid Drain40 °F850 m3/hourPre and After Filtration100 PSI50 °FJC0625-FH2840 lb80 psiJE-CC062527 inch500-40460V/3Ph/60Hz
TWB6001FY41NNN
Quote Required
TBD
112 inchAirtek6" Flg0(5) JAE3-FHIndustrial Gas Filtration and Generation Division146 inch120 °FBlower Purge120 °FJLA7206-C135 psiDemand Solenoid Drain40 °F10194 m3/hourPre and After Filtration100 PSI50 °FJLA6000-FH24890 lb80 psi(9) JAE3-C92 inch6000-40460V/3Ph/60Hz
TWB601BY41NNN
Quote Required
TBD
92 inchAirtek2" NPT0JE-FC0625-HTIndustrial Gas Filtration and Generation Division52 inch120 °FCompressed Air – Desiccant120 °FJC0625-C150 psiTimes Solenoid Drain40 °F1019 m3/hourPre and After Filtration100 PSI50 °FJC0625-FH3420 lb80 psiJE-CC062528 inch600-40460V/3Ph/60Hz
TWB7501FY41NNN
Quote Required
TBD
Consult Factory inchAirtek8" Flg0Consult FactoryIndustrial Gas Filtration and Generation DivisionConsult Factory inch120 °FCompressed Air – Desiccant120 °FConsult Factory135 psiDemand Solenoid Drain40 °F12743 m3/hourPre and After Filtration100 PSI50 °FConsult Factoryn/a Contact us80 psiConsult FactoryConsult Factory7500-40460V/3Ph/60Hz
TWB801BY41NNN
Quote Required
TBD
93 inchAirtek2" NPT0JE-FC0800-HTIndustrial Gas Filtration and Generation Division64 inch120 °FCompressed Air – Desiccant120 °FJC0800-C150 psiTimes Solenoid Drain40 °F1359 m3/hourPre and After Filtration100 PSI50 °FJC0800-FH4490 lb80 psiJE-CC080035 inch800-40460V/3Ph/60Hz
TWB9001FY41NNN
Quote Required
TBD
Consult FactoryAirtek8" Flg0Consult FactoryIndustrial Gas Filtration and Generation DivisionConsult Factory120Compressed Air – Desiccant120Consult Factory135Demand Solenoid Drain4015291Pre and After Filtration10050Consult Factoryn/a Contact us80Consult FactoryConsult Factory9000-40460V/3Ph/60Hz