- Availability & Price
- Search SKU
Filter by attributes
- Cable Assembly
- Mounting Option
- Wire Screen
Filter by manufacturer
Battery Charger, ThermoElectric- TEC Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker PGI’s Thermoelectric TEC Series Battery Charger uses proven thermo-electric technology to convert natural gas or propane to electric power. The TEC battery charger supplies 12 and 24-volt batteries with up to 7.3 watts of continuous power, regardless of available sunlight or other ambient conditions. The TEC is an ideal power source for electronic instruments, transmitters, flow computers, and communication systems on gas pipelines.
A thermoelectric charger is less expensive than electrical hook-ups or solar panel systems, and TEC excels in cold, snowy or rainy conditions. The compact and reliable TEC ensures that the battery is continuously charged and is also environmentally friendly, using low-emission catalytic technology to heat the thermoelectric modules.
CSA certified Class I, Div. 2.
Markets:
• Chemical
• Petrochemical
• Oil and Gas
• Power
Features/Benefits:
• Compact
• Proven thermo-electric technology
• 12 and 24 volt
• Converts natural gas / propane to electric power
Applications:
• Remote Power Source
• Gas Pipeline Instrumentation Source
Read More...A thermoelectric charger is less expensive than electrical hook-ups or solar panel systems, and TEC excels in cold, snowy or rainy conditions. The compact and reliable TEC ensures that the battery is continuously charged and is also environmentally friendly, using low-emission catalytic technology to heat the thermoelectric modules.
CSA certified Class I, Div. 2.
Markets:
• Chemical
• Petrochemical
• Oil and Gas
• Power
Features/Benefits:
• Compact
• Proven thermo-electric technology
• 12 and 24 volt
• Converts natural gas / propane to electric power
Applications:
• Remote Power Source
• Gas Pipeline Instrumentation Source
| Action | Part No. | Availability | Partner Available | Price | Division | Cable Assembly Type | Fuel Consumption | Minimum Operating Temperature | Includes | Additional Options | Weight | Output Power | For Fuel Type | Input Voltage | Mounting Option | Wire Mesh Screen Included | Maximum Operating Temperature | Mounting Option | Cable Assembly | Wire Screen |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TEC-8 | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | n/a | n/a | 120 | N/A | N/A | N/A | ||
| TEC-8-D | Quote Required | TBD | Instrumentation Products Division | Diagnostics Cable | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | n/a | n/a | 120 | N/A | Diagnostics Cable | N/A | ||
| TEC-8-DP1 | Quote Required | TBD | Instrumentation Products Division | Diagnostics Cable | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | CS 2" U-Bolts with Nuts | n/a | 120 | CS 2" U-Bolt w/nuts | Diagnostics Cable | N/A | ||
| TEC-8-DP2 | Quote Required | TBD | Instrumentation Products Division | Diagnostics Cable | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | SS 2" U-Bolts with Nuts | n/a | 120 | SS 2" U-Bolt w/nuts | Diagnostics Cable | N/A | ||
| TEC-8-P1 | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | CS 2" U-Bolts with Nuts | n/a | 120 | CS 2" U-Bolt w/nuts | N/A | N/A | ||
| TEC-8-P1S | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | CS 2" U-Bolts with Nuts | Heat Shield | 120 | CS 2" U-Bolt w/nuts | N/A | Heat Shield | ||
| TEC-8-P2 | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | SS 2" U-Bolts with Nuts | n/a | 120 | SS 2" U-Bolt w/nuts | N/A | N/A | ||
| TEC-8-P2S | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | SS 2" U-Bolts with Nuts | Heat Shield | 120 | SS 2" U-Bolt w/nuts | N/A | Heat Shield | ||
| TEC-8-S | Quote Required | TBD | Instrumentation Products Division | n/a | Natural Gas: 72 Cu. Ft./day [2.4 M3/day) | -40 | TEC in 304 SS Enclosure, Mounting Hardware, Supply Shut-off Valve with Strainer, Battery Interface Module and 20' [6 M] Battery Interface Harness | Cartridge Filter Canister with SS Mounting Bracket | Supply Shut-Off Valve with Strainer - Consult Factory | 50 | 6.3 to 7.3 W ( continuous at 68°F / 20°C ambient) | Natural Gas: 900-1100 BTU/cu. Ft. [31,783-38,845 BTU/M3] | Propane: 2400-2600 BTU/cu. Ft. [84,755-91,817 BTU/M3] | 12 VDC (system standard) | n/a | Heat Shield | 120 | N/A | N/A | Heat Shield |