• Availability & Price
  • Search SKU
Filter by attributes
  • Drain
  • Electrical Requirements
  • Flow Rate
  • Options
More Filters...
Filter by manufacturer
Manufacturers

Antares Series Low Energy Tandem Technology Compressed Air Dryer

Picture for category Antares Series Low Energy Tandem Technology Compressed Air Dryer

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Antares Tandem Technology dryers are an innovative family of compressed air dryers for volume flows from 360 to 2040 m³/h @ 7 bar g / PDP -40°C. Tandem Technology by Parker is a further development of the standard hybrid compressed air drying process. Compared to the conventional hybrid drying process, which is a simple lining-up of a refrigeration and an adsorption dryer, Tandem Technology goes one step further and fully integrates the two classic drying principles in a compact compressed air treatment package. This unique combination enables high-quality compressed air to be provided to the end-user with low energy consumption levels, when compared to more traditional adsorption dryers.

Benefits
• Reduced energy consumption up to 60% against traditional heatless desiccant dryers. This enables a payback time of less than 24 months. Higher savings are possible in partial load situations or when the required pressure dew point is above 0°C.

• The pressure dew point is freely adjustable between 5°C and -70°C, with no physical changes to the dryer. For example like changing an orifice, a nozzle or the type of desiccant material in order to reach the desired the dew point.

• Antares compressed air dryers can work with high compressed air inlet temperatures of up to 65°C.

• Very low cost of ownership due to reduced maintenance costs. Compared to standard adsorption dryers, Antares dryers need much less desiccant material. Additionally, some Antares models do not even need regular vessel inspections, the downtime therefore is very low.

• Antares help to keep process safety at a very high level with three integrated high performance OIL-X filters that are validated the demanding ISO12500 standard.

• Antares dryers are very compact, their footprint is considerably smaller compared to standard hybrid dryers of a similar performance.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionPort SizeConnection TypeSpecifications MetDepthWidthHeightWeightIndustryISO GradeApplicationNoise LevelProduct TypeProduct StyleProduct SeriesRefrigerant TypePower ConsumptionOperating PressurePressure Dew PointAmbient TemperatureCompatible PrefilterOperating TemperatureCompatible After FilterIngress Protection RatingOptionsDrainFlow RateElectrical RequirementsDivision
ATT060-A23015012EX
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch31.7 inch47.8 inch295 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW29 to 174 psigOptions: -70°C (-100°F) or -20°C (-4°F)50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use Onlyn/aExternal Electonic360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT060-A23015012EXTB
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch806.0 mm1215.0 mm650 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW2 to 12 bargStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)5 to 65 °COIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypassExternal Electonic360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT060-A23015012TI
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm806.0 mm47.8 inch650 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW2 to 12 bargOptions: -70°C (-100°F) or -20°C (-4°F)50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use Onlyn/aTimed Solenoid360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT060-A23015012TITB
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm31.7 inch47.8 inch295 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW2 to 12 bargOptions: -70°C (-100°F) or -20°C (-4°F)50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypassTimed Solenoid360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT060-A23015012TITBTP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch31.7 inch47.8 inch295 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW29 to 174 psigStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypass and Temperature ProbeTimed Solenoid360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT060-A23015012TITP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch31.7 inch47.8 inch650 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.27 kW29 to 174 psigStandard: -40°C (-40°F)<br/>122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyTemperature ProbeTimed Solenoid360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012EX
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm31.7 inch1220.0 mm739 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW4 to 12 bargStandard: -40°C (-40°F)<br/>122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)5 to 65 °COIL-X AOPX030G (Included)IP44 Indoor Use Onlyn/aExternal Electonic540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012EXC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm806.0 mm47.8 inch335 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW58 to 174 psigStandard: -40°C (-40°F)<br/>122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyModBus RS485External Electonic540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012EXTB
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm31.7 inch47.8 inch739 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW4 to 12 bargStandard: -40°C (-40°F)<br/>122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypassExternal Electonic540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012EXTBTP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch31.7 inch47.8 inch739 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW4 to 12 bargOptions: -70°C (-100°F) or -20°C (-4°F)122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypass and Temperature ProbeExternal Electonic360 m³/h @7 barg (240 cfm @102 psig)230V 1ph 50HzGas Separation and Filtration Division EMEA
ATT090-A23015012TI
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm806.0 mm47.8 inch335 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW58 to 174 psigStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)5 to 65 °COIL-X AOPX030G (Included)IP44 Indoor Use Onlyn/aTimed Solenoid540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012TITB
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm806.0 mm1224.0 mm335 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW4 to 12 bargStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)5 to 65 °COIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypassTimed Solenoid540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012TITBTP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II1416.0 mm806.0 mm1225.0 mm739 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW4 to 12 bargOptions: -70°C (-100°F) or -20°C (-4°F)122.0 °F MaximumOIL-X AOPX030G and AAPX030G (Included)41 to 149 °FOIL-X AOPX030G (Included)IP44 Indoor Use OnlyBypass and Temperature ProbeTimed Solenoid540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT090-A23015012TITP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA1-1/2 inchBSPPPED 2014/68/EU Fluid Group II55.7 inch31.7 inch1226.0 mm739 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c1.94 kW58 to 174 psigStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX030G and AAPX030G (Included)5 to 65 °COIL-X AOPX030G (Included)IP44 Indoor Use OnlyTemperature ProbeTimed Solenoid540 m³/h @7 barg (318 cfm @102 psig)230V 1ph 50Hz
ATT140-A40035012EI
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2 inchBSPPPED 2014/68/EU Fluid Group II53 inch39.6 inch1586.0 mm1080 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c2.01 kW4 to 12 bargOptions: -70°C (-100°F) or -20°C (-4°F)122.0 °F MaximumOIL-X AOPX045I and AAPX045I (Included)41 to 149 °FOIL-X AOPX045I (Included)IP44 Indoor Use Onlyn/aExternal Electonic840 m³/h @7 barg (494 cfm @102 psig)400V 3ph 50Hz
ATT140-A40035012EITB
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2 inchBSPPPED 2014/68/EU Fluid Group II1345.0 mm1007.0 mm1586.0 mm490 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c2.01 kW58 to 174 psigOptions: -70°C (-100°F) or -20°C (-4°F)50.0 °C MaximumOIL-X AOPX045I and AAPX045I (Included)41 to 149 °FOIL-X AOPX045I (Included)IP44 Indoor Use OnlyBypassExternal Electonic840 m³/h @7 barg (494 cfm @102 psig)400V 3ph 50Hz
ATT140-A40035012EITBTP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2 inchBSPPPED 2014/68/EU Fluid Group II1345.0 mm1007.0 mm1586.0 mm490 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c2.01 kW4 to 12 bargStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX045I and AAPX045I (Included)41 to 149 °FOIL-X AOPX045I (Included)IP44 Indoor Use OnlyBypass and Temperature ProbeExternal Electonic840 m³/h @7 barg (494 cfm @102 psig)400V 3ph 50Hz
ATT140-A40035012EITP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2 inchBSPPPED 2014/68/EU Fluid Group II53 inch39.6 inch62.4 inch1080 lbIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c2.01 kW58 to 174 psigOptions: -70°C (-100°F) or -20°C (-4°F)122.0 °F MaximumOIL-X AOPX045I and AAPX045I (Included)41 to 149 °FOIL-X AOPX045I (Included)IP44 Indoor Use OnlyTemperature ProbeExternal Electonic840 m³/h @7 barg (494 cfm @102 psig)400V 3ph 50Hz
ATT260-A40035012EI
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2-1/2 inchBSPPPED 2014/68/EU Fluid Group II2535.0 mm1007.0 mm1720.0 mm880 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c4.02 kW58 to 174 psigStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX055J and AAPX045I (Included)5 to 65 °COIL-X AOPX055J (Included)IP44 Indoor Use Onlyn/aExternal Electonic1560 m³/h @7 barg (918 cfm @102 psig)400V 3ph 50Hz
ATT260-A40035012EIC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEA2-1/2 inchBSPPPED 2014/68/EU Fluid Group II2535.0 mm1007.0 mm67.7 inch880 kgIndustrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/>Electronics<br/>Pharmaceuticals<br/>Medical & DentalStandard: Class 2.2.2<br/>Options: Class 2.1.2 or Class 2.3.2Compressed Air Applications< 75 dBACompressed Air DryerHybridAntaresR407c4.02 kW4 to 12 bargStandard: -40°C (-40°F)<br/>50.0 °C MaximumOIL-X AOPX055J and AOPX055J (Included)5 to 65 °COIL-X AOPX055J (Included)IP44 Indoor Use OnlyModBus RS485External Electonic1560 m³/h @7 barg (918 cfm @102 psig)400V 3ph 50Hz