- Availability & Price
- Search SKU
Filter by attributes
- Assembled Combined Valve Type
- Assembled Control Valve Type
- Capacity
- Diameter
- Input Voltage
- Maximum Flow Rate (lpm)
- Optional Accessories
- Sensor Connection
- Sensor type
Filter by manufacturer
Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.
Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
Read More...Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
| Action | Part No. | Availability | Partner Available | Price | Minimum Opening Pressure | Product Style | Pilot Port Size | Liquid Inlet Port Size | For Fluid Type | Maximum Operating Pressure | Division | Proof Pressure | Supply Air Inlet Port Size | Operating Temperature | Pilot Pressure Ratio | Sensor Connection | Capacity | Maximum Flow Rate (lpm) | Input Voltage | Optional Accessories | Assembled Control Valve Type | Sensor type | Assembled Combined Valve Type | Diameter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H3FG00014199 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | no sensor | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-in control) | no sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014200 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-in control) | 1 sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014201 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-in control) | 2 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014202 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-in control) | 3 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014203 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-in control) | 4 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014204 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | no sensor | 0.25 L | 40 | AC200V 50/60Hz | N/A | Flow control(Meter-in control) | no sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014205 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC200V 50/60Hz | N/A | Flow control(Meter-in control) | 1 sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014206 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC200V 50/60Hz | N/A | Flow control(Meter-in control) | 2 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014207 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC200V 50/60Hz | N/A | Flow control(Meter-in control) | 3 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014208 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC200V 50/60Hz | N/A | Flow control(Meter-in control) | 4 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014209 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | no sensor | 0.25 L | 40 | DC24V | N/A | Flow control(Meter-in control) | no sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014210 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | DC24V | N/A | Flow control(Meter-in control) | 1 sensor | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014211 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | DC24V | N/A | Flow control(Meter-in control) | 2 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014212 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | DC24V | N/A | Flow control(Meter-in control) | 3 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014213 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | DC24V | N/A | Flow control(Meter-in control) | 4 sensors | Nomal Close Skip Valve/Normal Open Stop Valve | 63 mm | ||
| H3FG00014214 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | no sensor | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-out control) | no sensor | Nomal Close Skip Valve | 63 mm | ||
| H3FG00014215 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-out control) | 1 sensor | Nomal Close Skip Valve | 63 mm | ||
| H3FG00014216 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-out control) | 2 sensors | Nomal Close Skip Valve | 63 mm | ||
| H3FG00014217 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-out control) | 3 sensors | Nomal Close Skip Valve | 63 mm | ||
| H3FG00014218 | Quote Required | TBD | 0.2 MPa | Air-Oil converter | Rc1/8 | Rc1/2 | Petroleum-based Fluid | 1 MPa | TAIYO Division | 1.5 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 0.3xMain pressure+0.25MPa to 0.7MPa | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | AC100V 50/60Hz | N/A | Flow control(Meter-out control) | 4 sensors | Nomal Close Skip Valve | 63 mm |