- Availability & Price
- Search SKU
Filter by attributes
- Assembled Combined Valve Type
- Assembled Control Valve Type
- Capacity
- Diameter
- Input Voltage
- Maximum Flow Rate (lpm)
- Optional Accessories
- Sensor Connection
- Sensor type
Filter by manufacturer
Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.
Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
Read More...Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
| Action | Part No. | Availability | Partner Available | Price | Pilot Port Size | Minimum Opening Pressure | Supply Air Inlet Port Size | Operating Temperature | Proof Pressure | For Fluid Type | Liquid Inlet Port Size | Pilot Pressure Ratio | Maximum Operating Pressure | Division | Product Style | Input Voltage | Assembled Control Valve Type | Assembled Combined Valve Type | Sensor type | Optional Accessories | Sensor Connection | Capacity | Maximum Flow Rate (lpm) | Diameter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H3FG00014159 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | no sensor | N/A | no sensor | 0.25 L | 40 | 63 mm | ||
| H3FG00014160 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 1 sensor | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014161 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 2 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014162 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 3 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014163 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 4 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014164 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | DC24V | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | no sensor | N/A | no sensor | 0.25 L | 40 | 63 mm | ||
| H3FG00014165 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | DC24V | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 1 sensor | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014166 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | DC24V | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 2 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014167 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | DC24V | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 3 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014168 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | DC24V | Flow control(Meter-out control) | Normal Open Skip Valve/Nomal Close Stop Valve | 4 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014169 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | no sensor | N/A | no sensor | 0.25 L | 40 | 63 mm | ||
| H3FG00014170 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 1 sensor | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014171 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 2 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014172 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 3 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014173 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 4 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014174 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | no sensor | N/A | no sensor | 0.25 L | 40 | 63 mm | ||
| H3FG00014175 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 1 sensor | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014176 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 2 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014177 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 3 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm | ||
| H3FG00014178 | Quote Required | TBD | Rc1/8 | 0.2 MPa | Rc3/8 | -5 ~+50 °C (No freezing) | 1.5 MPa | Petroleum-based Fluid | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 1 MPa | TAIYO Division | Air-Oil converter | AC200V 50/60Hz | Flow control(Meter-in control) | Normal Open Skip Valve/Nomal Close Stop Valve | 4 sensors | N/A | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | 0.25 L | 40 | 63 mm |