Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceProduct StyleMaximum Operating PressureOperating TemperatureDivisionPilot Pressure RatioPilot Port SizeFor Fluid TypeProof PressureLiquid Inlet Port SizeSupply Air Inlet Port SizeMinimum Opening PressureDiameterInput VoltageAssembled Control Valve TypeCapacitySensor typeOptional AccessoriesSensor ConnectionMaximum Flow Rate (lpm)Assembled Combined Valve Type
H3FG00014699
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-in control)0.4 Lno sensorN/Ano sensor40Nomal Close Skip Valve
H3FG00014700
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-in control)0.4 L1 sensorN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Nomal Close Skip Valve
H3FG00014701
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-in control)0.4 L2 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Nomal Close Skip Valve
H3FG00014702
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-in control)0.4 L3 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Nomal Close Skip Valve
H3FG00014703
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-in control)0.4 L4 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Nomal Close Skip Valve
H3FG00014704
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC100V 50/60HzFlow control(Meter-out control)0.4 Lno sensorN/Ano sensor40Normal Open Skip Valve
H3FG00014705
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC100V 50/60HzFlow control(Meter-out control)0.4 L1 sensorN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014706
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC100V 50/60HzFlow control(Meter-out control)0.4 L2 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014707
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC100V 50/60HzFlow control(Meter-out control)0.4 L3 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014708
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC100V 50/60HzFlow control(Meter-out control)0.4 L4 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014709
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC200V 50/60HzFlow control(Meter-out control)0.4 Lno sensorN/Ano sensor40Normal Open Skip Valve
H3FG00014710
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC200V 50/60HzFlow control(Meter-out control)0.4 L1 sensorN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014711
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC200V 50/60HzFlow control(Meter-out control)0.4 L2 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014712
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC200V 50/60HzFlow control(Meter-out control)0.4 L3 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014713
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmAC200V 50/60HzFlow control(Meter-out control)0.4 L4 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014714
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-out control)0.4 Lno sensorN/Ano sensor40Normal Open Skip Valve
H3FG00014715
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-out control)0.4 L1 sensorN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014716
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-out control)0.4 L2 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014717
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-out control)0.4 L3 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve
H3FG00014718
Quote Required
TBD
Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPaRc1/8Petroleum-based Fluid1.5 MPaRc1/2Rc3/80.2 MPa63 mmDC24VFlow control(Meter-out control)0.4 L4 sensorsN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Normal Open Skip Valve