• Availability & Price
  • Search SKU
Filter by attributes
  • Assembled Combined Valve Type
  • Assembled Control Valve Type
  • Capacity
  • Diameter
  • Input Voltage
  • Maximum Flow Rate (lpm)
  • Optional Accessories
  • Sensor Connection
  • Sensor type
More Filters...
Filter by manufacturer
Manufacturers

Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceProof PressureLiquid Inlet Port SizeFor Fluid TypeSupply Air Inlet Port SizeOperating TemperatureDivisionMinimum Opening PressurePilot Port SizeProduct StyleMaximum Operating PressurePilot Pressure RatioCapacitySensor typeAssembled Control Valve TypeAssembled Combined Valve TypeInput VoltageDiameterOptional AccessoriesSensor ConnectionMaximum Flow Rate (lpm)
H3FG00014679
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensorFlow control(Meter-out control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/Ano sensor40
H3FG00014680
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensorFlow control(Meter-out control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014681
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensorsFlow control(Meter-out control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014682
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensorsFlow control(Meter-out control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014683
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensorsFlow control(Meter-out control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014684
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensorFlow control(Meter-out control)Nomal Close Skip ValveDC24V63 mmN/Ano sensor40
H3FG00014685
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensorFlow control(Meter-out control)Nomal Close Skip ValveDC24V63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014686
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensorsFlow control(Meter-out control)Nomal Close Skip ValveDC24V63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014687
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensorsFlow control(Meter-out control)Nomal Close Skip ValveDC24V63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014688
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensorsFlow control(Meter-out control)Nomal Close Skip ValveDC24V63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014689
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensorFlow control(Meter-in control)Nomal Close Skip ValveAC100V 50/60Hz63 mmN/Ano sensor40
H3FG00014690
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensorFlow control(Meter-in control)Nomal Close Skip ValveAC100V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014691
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC100V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014692
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC100V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014693
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC100V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014694
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensorFlow control(Meter-in control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/Ano sensor40
H3FG00014695
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensorFlow control(Meter-in control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014696
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014697
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40
H3FG00014698
Quote Required
TBD
1.5 MPaRc1/2Petroleum-based FluidRc3/8-5 ~+50 °C (No freezing)TAIYO Division0.2 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensorsFlow control(Meter-in control)Nomal Close Skip ValveAC200V 50/60Hz63 mmN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40