Parker’s direct acting 4-way, 2-position spool-type solenoid valves feature a tough design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 113 lpm (30 gpm) and pressures up to 350 bar (5000 psi) with normally passing, crossing, or closed configurations available. Parker’s 4-way, 2-position spool-type solenoid valves are ideal for reversing or actuation applications; utilizing easily wired and programmed solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Reversing flow
• Actuator applications
• Single direction on/off applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and can quickly re-direct or block flow to actuator ports.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialBody MaterialMaximum Operating PressureDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureConfigurationWeightMaximum Inlet Pressure RatingFlow RateCavity SizeFunctionMaximum Flow RateMaximum Operating TemperatureActuation TypeFor Fluid TypeOperation TypeValve MaterialOperating TemperatureFilter Efficiency RatingMounting TypeInput VoltageOverride FunctionalityCoil Nut Tightening TorqueFlow DirectionCoil TypeInstallation TorqueLeak RateResponse TimeSeal MaterialMaximum Inlet Pressure RatingFlow RateActuation TypeConfigurationFlow Direction
DSH104BTV
Quote Required
TBD
Fluorocarbonn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °Cn/a0.2 kg350 bar10 Gal/minC10-44-Way38 L/min+400 °FElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ft3-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55 lb-ft320 @ 5000 PSI (350 BAR) cm3/min30-60 msFluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104BV
Quote Required
TBD
Fluorocarbonn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °Fn/a0.44 lb5000 psi38 L/minC10-44-Way38 L/min+400 °FElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minn/a7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil69-75 Nm320 @ 5000 PSI (350 BAR) cm3/min30-60 msFluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E1
Quote Required
TBD
D-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.2 kg350 bar10 Gal/minC10-44-Way38 L/min+200 °FElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minn/a7-10 NmAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55 lb-ft160 @ 5000 PSI (350 BAR) cm3/min30-60 msD-Ring (Standard)5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E15
Quote Required
TBD
D-Ring (Standard)n/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb5000 psi38 L/minC10-44-Way10 Gal/min+200 °FElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil69-75 Nm160 @ 5000 PSI (350 BAR) cm3/min30-60 msD-Ring (Standard)5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E15N
Quote Required
TBD
Nitrilen/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44500010C10-44-Way10+250ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Nitrile5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E15T
Quote Required
TBD
D-Ring (Standard)n/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb350 bar38 L/minC10-44-Way10 Gal/min+93 °CElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ft2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55 lb-ft160 @ 5000 PSI (350 BAR) cm3/min30-60 msD-Ring (Standard)5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E15TN
Quote Required
TBD
Nitrilen/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44500010C10-44-Way10+250Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Nitrile5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E15TV
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44500010C10-44-Way10+400Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Fluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E15V
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44500010C10-44-Way10+400ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Fluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized
DSH104E1N
Quote Required
TBD
Nitrilen/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °Fn/a0.2 kg350 bar38 L/minC10-44-Way38 L/min+250 °FElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ftAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55 lb-ft160 @ 5000 PSI (350 BAR) cm3/min30-60 msNitrile5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E1T
Quote Required
TBD
D-Ring (Standard)n/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb5000 psi38 L/minC10-44-Way10 Gal/min+200 °FElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ftAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil69-75 Nm160 @ 5000 PSI (350 BAR) cm3/min30-60 msD-Ring (Standard)5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E1TN
Quote Required
TBD
Nitrilen/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44500010C10-44-Way10+250Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Nitrile5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E1TV
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44500010C10-44-Way10+400Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Fluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E1V
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44500010C10-44-Way10+400ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Fluorocarbon5000 PSI, 350 BAR10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104E4
Quote Required
TBD
D-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.44 lb350 bar25 L/minC10-44-Way6.5 Gal/min+93 °CElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil69-75 Nm160 @ 5000 PSI (350 BAR) cm3/min30-60 msD-Ring (Standard)5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized
DSH104E4N
Quote Required
TBD
Nitrilen/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4450006.5C10-44-Way6.5+250ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-73 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Nitrile5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized
DSH104E4T
Quote Required
TBD
D-Ring (Standard)n/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35n/a0.4450006.5C10-44-Way6.5+200Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-35 to +200ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-73 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60D-Ring (Standard)5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized
DSH104E4TN
Quote Required
TBD
Nitrilen/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4450006.5C10-44-Way6.5+250Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-73 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Nitrile5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized
DSH104E4TV
Quote Required
TBD
Fluorocarbonn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °Cn/a0.2 kg350 bar6.5 Gal/minC10-44-Way25 L/min+204 °CElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist7-10 Nm3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil69-75 Nm160 @ 5000 PSI (350 BAR) cm3/min30-60 msFluorocarbon5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized
DSH104E4V
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.4450006.5C10-44-Way6.5+400ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-73 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil51-55160 @ 5000 PSI (350 BAR)30-60Fluorocarbon5000 PSI, 350 BAR6.5 GAL/MIN, 25 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized