• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Direction
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

4 Way 2 Position Spool Type Solenoid Valve

Picture for category 4 Way 2 Position Spool Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct acting 4-way, 2-position spool-type solenoid valves feature a tough design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 113 lpm (30 gpm) and pressures up to 350 bar (5000 psi) with normally passing, crossing, or closed configurations available. Parker’s 4-way, 2-position spool-type solenoid valves are ideal for reversing or actuation applications; utilizing easily wired and programmed solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Reversing flow
• Actuator applications
• Single direction on/off applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and can quickly re-direct or block flow to actuator ports.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceActuation TypeBody MaterialMaximum Operating PressureDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureConfigurationMaximum Operating TemperatureOverride FunctionalityWeightMaximum Inlet Pressure RatingSeal MaterialOperation TypeCavity SizeFunctionFor Fluid TypeValve MaterialFilter Efficiency RatingMounting TypeOperating TemperatureInput VoltageCoil Nut Tightening TorqueLeak RateCoil TypeInstallation TorqueResponse TimeFlow RateFlow DirectionMaximum Flow RateMaximum Inlet Pressure RatingSeal MaterialActuation TypeConfigurationFlow RateFlow DirectionDivision
DSH104H
Quote Required
TBD
Electricaln/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a+200 °Fn/a0.44 lb350 barD-Ring (Standard)Solenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F85% of rated voltage at 72°F (20°C) min5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil51-55 lb-ft30-60 ms27 L/min2-1, 3-4 De-Energized, 3-2, 4-1 Energized27 L/min5000 PSI, 350 BARD-Ring (Standard)ElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104HN
Quote Required
TBD
Electricaln/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a+250n/a0.445000NitrileSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +25085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARNitrileElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104HT
Quote Required
TBD
Electrical, Manualn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a+200 °FPush and Twist0.2 kg350 barD-Ring (Standard)Solenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-37 to +93 °C85% of rated voltage at 72°F (20°C) min5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil69-75 Nm30-60 ms7 Gal/min2-1, 3-4 De-Energized, 3-2, 4-1 Energized7 Gal/min5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104HTN
Quote Required
TBD
Electrical, Manualn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a+250Push and Twist0.445000NitrileSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +25085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARNitrileElectrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104HTV
Quote Required
TBD
Electrical, Manualn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a+400Push and Twist0.445000FluorocarbonSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +40085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARFluorocarbonElectrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104HV
Quote Required
TBD
Electricaln/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a+400n/a0.445000FluorocarbonSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +40085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARFluorocarbonElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized
DSH104M
Quote Required
TBD
Electricaln/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a+200 °Fn/a0.2 kg350 barD-Ring (Standard)Solenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-37 to +93 °C85% of rated voltage at 72°F (20°C) min7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil69-75 Nm30-60 ms27 L/min2-1, 3-4 De-Energized, All ports blocked Energized7 Gal/min5000 PSI, 350 BARD-Ring (Standard)ElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104MN
Quote Required
TBD
Electricaln/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a+250 °Fn/a0.2 kg5000 psiNitrileSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C85% of rated voltage at 72°F (20°C) min7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil51-55 lb-ft30-60 ms27 L/min2-1, 3-4 De-Energized, All ports blocked Energized7 Gal/min5000 PSI, 350 BARNitrileElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104MT
Quote Required
TBD
Electrical, Manualn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35n/a+200Push and Twist0.445000D-Ring (Standard)Solenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +20085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, All ports blocked Energized75000 PSI, 350 BARD-Ring (Standard)Electrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104MTN
Quote Required
TBD
Electrical, Manualn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a+250 °FPush and Twist0.44 lb5000 psiNitrileSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F85% of rated voltage at 72°F (20°C) min7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil69-75 Nm30-60 ms27 L/min2-1, 3-4 De-Energized, All ports blocked Energized27 L/min5000 PSI, 350 BARNitrileElectrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104MTV
Quote Required
TBD
Electrical, Manualn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °Cn/a+400 °FPush and Twist0.44 lb5000 psiFluorocarbonSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-26 to +204 °C85% of rated voltage at 72°F (20°C) min7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil69-75 Nm30-60 ms7 Gal/min2-1, 3-4 De-Energized, All ports blocked Energized27 L/min5000 PSI, 350 BARFluorocarbonElectrical, ManualN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104MV
Quote Required
TBD
Electricaln/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a+400n/a0.445000FluorocarbonSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +40085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-6072-1, 3-4 De-Energized, All ports blocked Energized75000 PSI, 350 BARFluorocarbonElectricalN/A7 GAL/MIN, 27 L/MIN2-1, 3-4 De-Energized, All ports blocked Energized
DSH104N
Quote Required
TBD
Electricaln/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a+93 °Cn/a0.44 lb350 barD-Ring (Standard)Solenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F85% of rated voltage at 72°F (20°C) min5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil51-55 lb-ft30-60 ms27 L/minAll ports blocked De-Energized, 3-2, 4-1 Energized27 L/min5000 PSI, 350 BARD-Ring (Standard)ElectricalN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104NN
Quote Required
TBD
Electricaln/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a+250 °Fn/a0.2 kg5000 psiNitrileSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C85% of rated voltage at 72°F (20°C) min5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil51-55 lb-ft30-60 ms7 Gal/minAll ports blocked De-Energized, 3-2, 4-1 Energized27 L/min5000 PSI, 350 BARNitrileElectricalN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104NT
Quote Required
TBD
Electrical, Manualn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35n/a+200Push and Twist0.445000D-Ring (Standard)Solenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +20085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-607All ports blocked De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARD-Ring (Standard)Electrical, ManualN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104NTN
Quote Required
TBD
Electrical, Manualn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °Fn/a+250 °FPush and Twist0.44 lb350 barNitrileSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250 °F85% of rated voltage at 72°F (20°C) min7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min5/8" Super Coil51-55 lb-ft30-60 ms27 L/minAll ports blocked De-Energized, 3-2, 4-1 Energized27 L/min5000 PSI, 350 BARNitrileElectrical, ManualN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104NTV
Quote Required
TBD
Electrical, Manualn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a+400Push and Twist0.445000FluorocarbonSolenoid operated, Manually operatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +40085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-607All ports blocked De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARFluorocarbonElectrical, ManualN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH104NV
Quote Required
TBD
Electricaln/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a+400n/a0.445000FluorocarbonSolenoid OperatedC10-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +40085% of rated voltage at 72°F (20°C)5-7160 @ 5000 PSI (350 BAR)5/8" Super Coil51-5530-607All ports blocked De-Energized, 3-2, 4-1 Energized75000 PSI, 350 BARFluorocarbonElectricalN/A7 GAL/MIN, 27 L/MINAll ports blocked De-Energized, 2-1, 3-4 Energized
DSH164HR
Quote Required
TBD
Electricaln/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °FMotor Regen Transition+121 °Cn/a0.59 kg5000 psiNitrileSolenoid OperatedC16-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-34 to +121 °C85% of rated voltage at 72°F (20°C) min7-10 Nm350 De-energized, 1.5 GPM Energized Pilot Flow @ 3000 PSI (207 BAR) cm3/min1/2" Super Coil40.6-54.2 Nm130 ms30 Gal/min2-1, 3-4 De-Energized, 3-2, 4-1 Energized113 L/min5000 PSI, 350 BARNitrileElectricalMotor Regen Transition30 GAL/MIN, 113 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 EnergizedHydraulic Cartridge Systems Division
DSH164HRV
Quote Required
TBD
Electricaln/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °FMotor Regen Transition+400 °Fn/a0.59 kg5000 psiFluorocarbonSolenoid OperatedC16-44-WayMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F85% of rated voltage at 72°F (20°C) min7-10 Nm350 De-energized, 1.5 GPM Energized Pilot Flow @ 3000 PSI (207 BAR) cm3/min1/2" Super Coil30-40 lb-ft130 ms30 Gal/min2-1, 3-4 De-Energized, 3-2, 4-1 Energized30 Gal/min5000 PSI, 350 BARFluorocarbonElectricalMotor Regen Transition30 GAL/MIN, 113 L/MIN2-1, 3-4 De-Energized, 3-2, 4-1 Energized