• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Direction
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

4 Way 2 Position Spool Type Solenoid Valve

Picture for category 4 Way 2 Position Spool Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct acting 4-way, 2-position spool-type solenoid valves feature a tough design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 113 lpm (30 gpm) and pressures up to 350 bar (5000 psi) with normally passing, crossing, or closed configurations available. Parker’s 4-way, 2-position spool-type solenoid valves are ideal for reversing or actuation applications; utilizing easily wired and programmed solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Reversing flow
• Actuator applications
• Single direction on/off applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and can quickly re-direct or block flow to actuator ports.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialMinimum Operating TemperatureDivisionMaximum Kinematic ViscosityConfigurationFlow RateWeightMaximum Flow RateCavity SizeFunctionActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureMounting TypeCoil TypeInput VoltageResponse TimeCoil Nut Tightening TorqueFlow DirectionInstallation TorqueOverride FunctionalityMaximum Operating PressureMaximum Inlet Pressure RatingLeak RateSeal MaterialFlow RateActuation TypeConfigurationFlow DirectionMaximum Inlet Pressure Rating
DSL084NPN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a30.293C08-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C)505-7All ports blocked De-Energized, 3-2, 4-1 Energized23-27Pull and Release36003600160 @ 3600 PSI (250 BAR)Nitrile3 GAL/MIN, 11 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL084NPV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a30.293C08-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C)505-7All ports blocked De-Energized, 3-2, 4-1 Energized23-27Pull and Release36003600160 @ 3600 PSI (250 BAR)Fluorocarbon3 GAL/MIN, 11 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL084NT
Quote Required
TBD
D-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a11 L/min0.29 lb3 Gal/minC08-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+200 °FScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms7-10 NmAll ports blocked De-Energized, 3-2, 4-1 Energized31-37 NmPush and Twist3600 psi3600 psi160 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)3 GAL/MIN, 11 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL084NTN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a30.293C08-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C)505-7All ports blocked De-Energized, 3-2, 4-1 Energized23-27Push and Twist36003600160 @ 3600 PSI (250 BAR)Nitrile3 GAL/MIN, 11 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL084NTV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a30.293C08-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C)505-7All ports blocked De-Energized, 3-2, 4-1 Energized23-27Push and Twist36003600160 @ 3600 PSI (250 BAR)Fluorocarbon3 GAL/MIN, 11 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL084NV
Quote Required
TBD
Fluorocarbonn/a-15 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a3 Gal/min0.29 lb3 Gal/minC08-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400 °F+204 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms5-7 lb-ftAll ports blocked De-Energized, 3-2, 4-1 Energized23-27 lb-ftn/a250 bar250 bar160 @ 3600 PSI (250 BAR) cm3/minFluorocarbon3 GAL/MIN, 11 L/MINElectricalN/AAll ports blocked De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104B
Quote Required
90 In Stock
$61.69
EAD-Ring (Standard)n/a-35 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a10 Gal/min0.2 kg10 Gal/minC10-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+200 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized50-56 Nmn/a250 bar3600 psi230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104B2
Quote Required
TBD
D-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a38 L/min0.2 kg38 L/minC10-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+200 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms5-7 lb-ft3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized50-56 Nmn/a250 bar250 bar230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2N
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41n/a36003600230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2P
Quote Required
TBD
D-Ring (Standard)n/a-35Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Pull and Release36003600230 @ 3600 PSI (250 BAR)D-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2PN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Pull and Release36003600230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2PV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Pull and Release36003600230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2T
Quote Required
TBD
D-Ring (Standard)n/a-35Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Push and Twist36003600230 @ 3600 PSI (250 BAR)D-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2TN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Push and Twist36003600230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2TV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized37-41Push and Twist36003600230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104B2V
Quote Required
TBD
Fluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a38 L/min0.2 kg10 Gal/minC10-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-26 to +204 °C+204 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms7-10 Nm3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized50-56 Nmn/a250 bar250 bar230 @ 3600 PSI (250 BAR) cm3/minFluorocarbon10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104BN
Quote Required
$67.50
EANitrilen/a-34 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a38 L/min0.2 kg10 Gal/minC10-44-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250 °F+250 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized50-56 Nmn/a3600 psi3600 psi230 @ 3600 PSI (250 BAR) cm3/minNitrile10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BP
Quote Required
TBD
D-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a38 L/min0.44 lb10 Gal/minC10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-37 to +93 °C+93 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized50-56 NmPull and Release250 bar3600 psi230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BPN
Quote Required
TBD
Nitrilen/a-30 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a10 Gal/min0.2 kg10 Gal/minC10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min30-60 ms7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized50-56 NmPull and Release250 bar3600 psi230 @ 3600 PSI (250 BAR) cm3/minNitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BPV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)n/a100.4410C10-44-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C)30-605-73-2, 4-1 De-Energized, 2-1, 3-4 Energized37-41Pull and Release36003600230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR