• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Direction
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

3 Way Solenoid Valves for High Pressure Hydraulic Applications

Picture for category 3 Way Solenoid Valves for High Pressure Hydraulic Applications

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct acting 3-way, 2-position spool-type solenoid valves feature a proven design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 57 lpm (15 gpm) and pressures up to 350 bar (5000 psi) with normally-open, normally closed, or selector configurations available. Parker’s 3-way, 2-position spool-type solenoid valves are ideal for switching or unloading applications that don’t necessarily require low poppet style leakage, but instead easy solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Switching applications
• Unloading applications
• Diverter applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and will allow flow passage between 2 ports while blocking the remaining port.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialMaximum Operating PressureDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureFunctionWeightMaximum Inlet Pressure RatingFlow RateCavity SizeConfigurationActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingMaximum Operating TemperatureMounting TypeCoil TypeInput VoltageResponse TimeInstallation TorqueOverride FunctionalityCoil Nut Tightening TorqueLeak RateFlow DirectionMaximum Flow RateOperating TemperatureSeal MaterialConfigurationMaximum Inlet Pressure RatingActuation TypeFlow RateFlow Direction
DSH083CTV
Quote Required
TBD
Fluorocarbonn/a5000Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-153-Way0.2850004C08-3Normally OpenElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400Screw in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C)5032-36Push and Twist5-7160 @ 5000 PSI (350 BAR)3-1 De-energized, 2-1 Energized4-26 to +204FluorocarbonNormally Open5000 PSI, 350 BARElectrical, Manual4 GAL/MIN, 15 L/MIN3-1 De-energized, 2-1 Energized
DSH083CV
Quote Required
TBD
Fluorocarbonn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C3-Way0.28 lb350 bar4 Gal/minC08-3Normally OpenElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms43-49 Nmn/a7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min3-1 De-energized, 2-1 Energized15 L/min-15 to +400 °FFluorocarbonNormally Open5000 PSI, 350 BARElectrical4 GAL/MIN, 15 L/MIN3-1 De-energized, 2-1 Energized
DSH083N
Quote Required
11 In Stock
$61.31
EAD-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °F3-Way0.13 kg5000 psi3, 4 Gal/minC08-3Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms43-49 Nmn/a7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized15 L/min-37 to +93 °CD-Ring (Standard)Normally Open, Selector5000 PSI, 350 BARElectrical3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH083NN
Quote Required
TBD
Nitrilen/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F3-Way0.28 lb5000 psi3, 4 Gal/minC08-3Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms43-49 Nmn/a5-7 lb-ft250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized15 L/min-34 to +121 °CNitrileNormally Open, Selector5000 PSI, 350 BARElectrical3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH083NT
Quote Required
TBD
D-Ring (Standard)n/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °C3-Way0.13 kg350 bar3, 4 Gal/minC08-3Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ftPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized15 L/min-35 to +200 °FD-Ring (Standard)Normally Open, Selector5000 PSI, 350 BARElectrical, Manual3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH083NTN
Quote Required
TBD
Nitrilen/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F3-Way0.13 kg350 bar3, 4 Gal/minC08-3Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ftPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized4 Gal/min-30 to +250 °FNitrileNormally Open, Selector5000 PSI, 350 BARElectrical, Manual3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH083NTV
Quote Required
TBD
Fluorocarbonn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F3-Way0.13 kg350 bar3, 4 Gal/minC08-3Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ftPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized4 Gal/min-15 to +400 °FFluorocarbonNormally Open, Selector5000 PSI, 350 BARElectrical, Manual3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH083NV
Quote Required
$67.31
EAFluorocarbonn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F3-Way0.28 lb5000 psi11.3, 15 L/minC08-3Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400 °FScrew in cartridge valve1/2" Super Coil85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ftn/a5-7 lb-ft250 @ 5000 PSI (350 BAR) cm3/min2-3 De-energized, 2-1 Energized15 L/min-15 to +400 °FFluorocarbonNormally Open, Selector5000 PSI, 350 BARElectrical3, 4 GAL/MIN, 11.3, 15 L/MIN2-3 De-energized, 2-1 Energized
DSH103A
Quote Required
8 In Stock
$68.81
EAD-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °C3-Way0.19 kg350 bar4. 4.5 Gal/minC10-3Normally Closed, Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 Nmn/a7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized17 L/min-35 to +200 °FD-Ring (Standard)Normally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103AN
Quote Required
TBD
Nitrilen/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C3-Way0.19 kg350 bar15, 17 L/minC10-3Normally Closed, Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms51-55 lb-ftn/a5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized17 L/min-34 to +121 °CNitrileNormally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103AT
Quote Required
TBD
D-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °C3-Way0.42 lb350 bar15, 17 L/minC10-3Normally Closed, Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms51-55 lb-ftPush and Twist5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized4.5 Gal/min-34 to +121 °CD-Ring (Standard)Normally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical, Manual4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103ATN
Quote Required
TBD
Nitrilen/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C3-Way0.19 kg5000 psi15, 17 L/minC10-3Normally Closed, Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 NmPush and Twist5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized4.5 Gal/min-34 to +121 °CNitrileNormally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical, Manual4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103ATV
Quote Required
TBD
Fluorocarbonn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C3-Way0.19 kg350 bar4. 4.5 Gal/minC10-3Normally Closed, Normally Open, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 NmPush and Twist5-7 lb-ft160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized4.5 Gal/min-15 to +400 °FFluorocarbonNormally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical, Manual4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103AV
Quote Required
TBD
Fluorocarbonn/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C3-Way0.42 lb350 bar4. 4.5 Gal/minC10-3Normally Closed, Normally Open, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms51-55 lb-ftn/a7-10 Nm160 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 3-1 Energized4.5 Gal/min-26 to +204 °CFluorocarbonNormally Closed, Normally Open, Selector5000 PSI, 350 BARElectrical4, 4.5 GAL/MIN, 15, 17 L/MIN2-1 De-energized, 3-1 Energized
DSH103B
Quote Required
17 In Stock
$66.56
EAD-Ring (Standard)n/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °C3-Way0.42 lb350 bar30 L/minC10-3Normally Closed, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms51-55 lb-ftn/a5-7 lb-ft250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized8 Gal/min-37 to +93 °CD-Ring (Standard)Normally Closed, Selector5000 PSI, 350 BARElectrical8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized
DSH103BN
Quote Required
TBD
Nitrilen/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F3-Way0.19 kg350 bar8 Gal/minC10-3Normally Closed, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 Nmn/a5-7 lb-ft250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized8 Gal/min-34 to +121 °CNitrileNormally Closed, Selector5000 PSI, 350 BARElectrical8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized
DSH103BT
Quote Required
TBD
D-Ring (Standard)n/a5000 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °F3-Way0.42 lb5000 psi8 Gal/minC10-3Normally Closed, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 NmPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized8 Gal/min-35 to +200 °FD-Ring (Standard)Normally Closed, Selector5000 PSI, 350 BARElectrical, Manual8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized
DSH103BTN
Quote Required
TBD
Nitrilen/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C3-Way0.42 lb5000 psi30 L/minC10-3Normally Closed, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 NmPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized8 Gal/min-34 to +121 °CNitrileNormally Closed, Selector5000 PSI, 350 BARElectrical, Manual8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized
DSH103BTV
Quote Required
TBD
Fluorocarbonn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C3-Way0.19 kg350 bar8 Gal/minC10-3Normally Closed, SelectorElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms51-55 lb-ftPush and Twist7-10 Nm250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized30 L/min-15 to +400 °FFluorocarbonNormally Closed, Selector5000 PSI, 350 BARElectrical, Manual8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized
DSH103BV
Quote Required
TBD
Fluorocarbonn/a350 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F3-Way0.19 kg350 bar30 L/minC10-3Normally Closed, SelectorElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400 °FScrew in cartridge valve5/8" Super Coil85% of rated voltage at 72°F (20°C) min50-100 ms69-75 Nmn/a5-7 lb-ft250 @ 5000 PSI (350 BAR) cm3/min2-1 De-energized, 2-3 Energized8 Gal/min-26 to +204 °CFluorocarbonNormally Closed, Selector5000 PSI, 350 BARElectrical8 GAL/MIN, 30 L/MIN2-1 De-energized, 2-3 Energized