• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
  • Wire Mesh Screen Included
More Filters...
Filter by manufacturer
Manufacturers

2 Way Poppet Type Solenoid Valve

Picture for category 2 Way Poppet Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceFlow RateWire Mesh Screen IncludedMaximum Operating PressureFree Reverse FlowActuation TypeSeal MaterialCoil Nut Tightening TorqueWeightResponse TimeMaximum Inlet Pressure RatingFilter Efficiency RatingMaximum Kinematic ViscosityAdjustment MechanismValve MaterialFlow DirectionFunctionConfigurationFor Fluid TypeCoil TypeCavity SizeOverride FunctionalityMaximum Operating TemperatureMounting TypeMaximum Flow RateOperation TypeLeak RateInput VoltageBody MaterialMinimum Operating TemperatureInstallation TorqueOperating TemperatureDivisionSeal MaterialConfigurationFlow RateActuation TypeWire Mesh Screen IncludedMaximum Inlet Pressure Rating
DSL081NREV
Quote Required
$97.50/each
30 L/minNo3600 psiYesElectrical, ManualFluorocarbon5-7 lb-ft0.25 lb50 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids1/2" Super CoilC08-2Push Type w/Extended Rod+400 °FScrew in cartridge valve8 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-15 °F23-27 lb-ft-15 to +400 °FHydraulic Systems DivisionFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL081NRM
Quote Required
34 In Stock
$113.18/each
8 Gal/minNo250 barYesElectrical, ManualD-Ring (Standard)5-7 lb-ft0.11 kg50 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids1/2" Super CoilC08-2Push Type w/Flush Rod+200 °FScrew in cartridge valve8 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F23-27 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Open8 GAL/MIN, 30 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL081NRTVS
Quote Required
$138.00/each
30 L/minYes250 barYesElectrical, ManualFluorocarbon7-10 Nm0.25 lb50 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids1/2" Super CoilC08-2Push and Twist+204 °CScrew in cartridge valve30 L/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-26 °C23-27 lb-ft-26 to +204 °CHydraulic Systems DivisionFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectrical, ManualYes3600 PSI, 250 BAR
DSL081NRV
Quote Required
$84.25/each
30 L/minNo250 barYesElectricalFluorocarbon5-7 lb-ft0.25 lb50 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids1/2" Super CoilC08-2N/A+400 °FScrew in cartridge valve8 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-26 °C23-27 lb-ft-26 to +204 °CHydraulic Systems DivisionFluorocarbonNormally Open8 GAL/MIN, 30 L/MINElectricalNo3600 PSI, 250 BAR
DSL081NV
Quote Required
$72.50/each
8 Gal/minNo3600 psiNoElectricalFluorocarbon7-10 Nm0.25 lb50 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids1/2" Super CoilC08-2N/A+400 °FScrew in cartridge valve30 L/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-26 °C31-37 Nm-15 to +400 °FHydraulic Systems DivisionNitrileNormally Open8 GAL/MIN, 30 L/MINElectricalNo3600 PSI, 250 BAR
DSL101C
3 In Stock
61 In Stock
$61.50/each
60 L/minNo3600 psiNoElectricalD-Ring (Standard)5-7 lb-ft0.41 lb80 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+200 °FScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CHR
Quote Required
1 Limited Stock
$81.40/each
60 L/minNo3600 psiYesElectricalD-Ring (Standard)5-7 lb-ft0.41 lb50 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+200 °FScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CP
4 In Stock
6 In Stock
$107.75/each
60 L/minNo3600 psiNoElectrical, ManualD-Ring (Standard)5-7 lb-ft0.41 lb80 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Pull and Release+200 °FScrew in cartridge valve60 L/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F50-56 Nm-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CR
Quote Required
31 In Stock
$84.49/each
15 Gal/minNo250 barYesElectricalD-Ring (Standard)7-10 Nm0.2 kg80 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+93 °CScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CRP
Quote Required
$113.25/each
15 Gal/minNo250 barYesElectrical, ManualD-Ring (Standard)7-10 Nm0.2 kg80 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Pull and Release+200 °FScrew in cartridge valve60 L/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-37 °C50-56 Nm-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRPN
Quote Required
$118.25/each
15No3600YesElectrical, ManualNitrile5-70.41803600ISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Pull and Release+250Screw in cartridge valve15Solenoid operated, Manually operated585% of rated voltage at 72°F (20°C)N/A-3037-41-30 to +250Hydraulic Systems DivisionNitrileNormally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRT
Quote Required
301 In Stock
$143.89/each
15 Gal/minNo250 barYesElectrical, ManualD-Ring (Standard)7-10 Nm0.2 kg80 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push and Twist+93 °CScrew in cartridge valve15 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101CRV
Quote Required
$71.75/each
15 Gal/minNo3600 psiYesElectricalFluorocarbon5-7 lb-ft0.2 kg80 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+204 °CScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-15 °F37-41 lb-ft-15 to +400 °FHydraulic Systems DivisionFluorocarbonNormally Closed15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101CT
Quote Required
4 In Stock
$131.51/each
60 L/minNo3600 psiNoElectrical, ManualD-Ring (Standard)5-7 lb-ft0.2 kg80 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally ClosedMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push and Twist+200 °FScrew in cartridge valve60 L/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101N
62 In Stock
61 In Stock
$80.75/each
60 L/minNo3600 psiNoElectricalD-Ring (Standard)5-7 lb-ft0.41 lb35 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+200 °FScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101NE
Quote Required
1 Limited Stock
$105.62/each
60 L/minNo250 barNoElectrical, ManualD-Ring (Standard)5-7 lb-ft0.2 kg35 ms3600 psiISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push Type w/Extended Rod+200 °FScrew in cartridge valve60 L/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-37 °C50-56 Nm-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NM
Quote Required
39 In Stock
$114.42/each
60 L/minNo250 barNoElectrical, ManualD-Ring (Standard)7-10 Nm0.41 lb35 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push Type w/Flush Rod+93 °CScrew in cartridge valve15 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F50-56 Nm-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NR
Quote Required
49 In Stock
$108.59/each
60 L/minNo250 barYesElectricalD-Ring (Standard)7-10 Nm0.41 lb35 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2N/A+200 °FScrew in cartridge valve15 Gal/minSolenoid operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-37 °C37-41 lb-ft-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectricalNo3600 PSI, 250 BAR
DSL101NRE
Quote Required
$101.75/each
60 L/minNo3600 psiYesElectrical, ManualD-Ring (Standard)5-7 lb-ft0.41 lb35 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push Type w/Extended Rod+93 °CScrew in cartridge valve15 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-35 to +200 °FHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR
DSL101NRM
Quote Required
32 In Stock
$124.49/each
15 Gal/minNo3600 psiYesElectrical, ManualD-Ring (Standard)7-10 Nm0.2 kg35 ms250 barISO 4406 18/16/13, SAE Class 445-2000 SSU (6 to 420 cSt)N/AAll parts steel. All operating parts hardened steelSide to Nose (2-1)2-wayNormally OpenMineral-based or synthetic hydraulic fluids5/8" Super CoilC10-2Push Type w/Flush Rod+200 °FScrew in cartridge valve15 Gal/minSolenoid operated, Manually operated5 drops/min85% of rated voltage at 72°F (20°C) minN/A-35 °F37-41 lb-ft-37 to +93 °CHydraulic Systems DivisionD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MINElectrical, ManualNo3600 PSI, 250 BAR